Effect of norepinephrine on blood volume , cardiac output, and systemic filling pressure in patients undergoing liver transplantation

被引:1
|
作者
Mukhtar, Ahmed M. [1 ,5 ]
Fahmy, Ehab T. [1 ]
Eladawy, Akram A. [1 ]
Ali, Mohamed [1 ]
Elayashy, Mohamed [2 ]
Saner, Fuat [3 ]
Abdelaal, Amr [4 ]
Abdo, Mostafa [4 ]
Hussein, Amr S. [2 ]
机构
[1] Cairo Univ, Cairo, Egypt
[2] Cairo Univ, Kasralainy Fac Med, Anesthesia Surg ICU & Pain Management, Cairo, Egypt
[3] Univ Hosp Essen, Dept Gen Visceral& Transplantat Surg, Essen, Germany
[4] Ain Shams Univ, Cairo, Egypt
[5] 1 Saray St El Manial, Cairo, Egypt
关键词
Norepinephrine; Liver transplantation; Cardiac outoput; VENOUS RETURN; HEMODYNAMICS; CIRCULATION;
D O I
10.23736/S0375-9393.22.16526-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Patients with liver cirrhosis develop symptoms comparable to those of patients with sepsis, who have increased total vascular compliance, which may cause blood pooling in the venous pool. No previous studies have evaluated the effect of using norepinephrine on the intravascular blood volume. We investigated the norepinephrine infusion's effect on the mean systemic filling pressure, venous return, and cardiac preload in patients undergoing liver transplantation. METHODS: Overall, 33 patients who underwent living donor liver transplantation were included in this study. Cardiac output (CO) was measured using a PiCCO device (Pulsion Medical Systems, Munich, Germany). The mean systemic filling pressure was calculated using the inspiratory hold maneuver at four time intervals -at baseline, 10 min after the norepinephrine infusion, 5 min after norepinephrine discontinuation, and after infusion of 500 cc of 5% albumin. Other hemodynamic parameters, including the mean arterial pressure (MAP), pulse pressure variation, stroke volume variation, global end-diastolic volume, and mitral inflow velocity (E wave), were also evaluated. RESULTS: The norepinephrine infusion increased MAP and systemic vascular resistance in all patients. Moreover, it increased CO, mean systemic filling pressure, and global end-diastolic volume in 20 patients (60%), whereas there were no changes in these variables in 13 patients (40%). In all patients, norepinephrine infusion discontinuation caused a significant decrease in MAP, CO, resistance to venous return, and mean systemic filling pressure. Infusion of 500 cc colloid increased CO; however, interestingly, it was associated with a significant decrease in systemic vascular resistance; hence, MAP and mean systemic filling pressure showed no changes. CONCLUSIONS: The norepinephrine infusion at 0.1 mu g(-1) kg(-1) min(-1 )was associated with an increase in CO in patients with liver cirrhosis undergoing liver transplantation. Norepinephrine's effect on CO was primarily attributable to an increase in venous return due to an increase in mean systemic filling pressure.
引用
收藏
页码:1013 / 1020
页数:8
相关论文
共 50 条
  • [1] Effect of norepinephrine on blood volume, cardiac output, and systemic filling pressure in patients undergoing liver transplantation
    Mukhtar, A.
    Fahmy, E.
    Eladawy, A.
    Ali, M.
    Elayashy, M.
    Saner, F.
    Abdo, M.
    Abdelaal, A.
    Huseein, A.
    TRANSPLANTATION, 2022, 106 (8S) : 15 - 15
  • [2] EFFECTS OF NOREPINEPHRINE ON MEAN SYSTEMIC FILLING PRESSURE AND CARDIAC OUTPUT IN PATIENTS WITH SEPTIC SHOCK
    Ding, Lili
    Sun, Haijun
    ACTA MEDICA MEDITERRANEA, 2023, 39 (01): : 225 - 228
  • [3] OBSERVATIONS ON CARDIAC OUTPUT, BLOOD VOLUME, CENTRAL VENOUS PRESSURE, FLUID AND ELECTROLYTE CHANGES IN PATIENTS UNDERGOING TRANSURETHRAL PROSTATECTOMY
    MEBUST, WK
    BRADY, TW
    VALK, WL
    JOURNAL OF UROLOGY, 1970, 103 (05): : 632 - +
  • [4] Effect of terlipressin on systemic and hepatic hemodynamics in patients undergoing liver transplantation
    Hashim, Reham Mustafa
    Radwan, Nada Mohamed
    Elsafty, Omar Mohamed Taha
    Ibrahim, Waleed Abdalla
    Shabana, Tarek Samir
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2023, 39 (01): : 432 - 439
  • [5] EFFECT OF NOREPINEPHRINE, HEXAMETHONIUM AND HYDRALAZINE ON MEAN CIRCULATORY FILLING PRESSURE - BLOOD-VOLUME RELATIONSHIP IN RAT
    YAMAMOTO, J
    TRIPPODO, NC
    WALSH, GM
    ISHISE, S
    FROHLICH, ED
    CLINICAL RESEARCH, 1978, 26 (06): : A755 - A755
  • [6] EFFECT OF BLOOD VOLUME MEAN CIRCULATORY PRESSURE AND STRESS RELAXATION ON CARDIAC OUTPUT
    PRATHER, JW
    TAYLOR, AE
    GUYTON, AC
    AMERICAN JOURNAL OF PHYSIOLOGY, 1969, 216 (03): : 467 - &
  • [7] Clinical evaluation of the NICO cardiac output monitor in patients undergoing orthotopic liver transplantation
    Epstein, RH
    Audu, PB
    ANESTHESIOLOGY, 1999, 91 (3A) : U271 - U271
  • [8] EFFECT OF NOREPINEPHRINE ON CARDIAC OUTPUT ARTERIAL BLOOD PRESSURE, AND HEART RATE IN DOGS TREATED WITH CHLOROTHIAZIDE
    ECKSTEIN, JW
    PEREDA, SA
    ABBOUD, FM
    JOURNAL OF CLINICAL INVESTIGATION, 1962, 41 (08): : 1578 - &
  • [9] The effect of propofol on haemodynamics: cardiac output, venous return, mean systemic filling pressure, and vascular resistances
    de Wit, F.
    van Vliet, A. L.
    de Wilde, R. B.
    Jansen, J. R.
    Vuyk, J.
    Aarts, L. P.
    de Jonge, E.
    Veelo, D. P.
    Geerts, B. F.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : 784 - 789
  • [10] THE EFFECT OF MEAN ENDOTRACHEAL PRESSURE ON THE CARDIAC OUTPUT OF PATIENTS UNDERGOING INTRATHORACIC OPERATIONS
    NEALON, TF
    CATHCART, RT
    FRAIMOW, W
    MCLAUGHLIN, ED
    GIBBON, JH
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1959, 38 (04): : 449 - 457