Zinc oxide nanocomb biosensor for glucose detection

被引:543
|
作者
Wang, J. X.
Sun, X. W.
Wei, A.
Lei, Y.
Cai, X. P.
Li, C. M.
Dong, Z. L.
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 639798, Singapore
[3] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore 639798, Singapore
关键词
D O I
10.1063/1.2210078
中图分类号
O59 [应用物理学];
学科分类号
摘要
Single crystal zinc oxide nanocombs were synthesized in bulk quantity by vapor phase transport. A glucose biosensor was constructed using these nanocombs as supporting materials for glucose oxidase (GO,) loading. The zinc oxide nanocomb glucose biosensor showed a high sensitivity (15.33 mu A/cm(2) MM) for glucose detection and high affinity of GO(x) to glucose (the apparent K-M(app)=2.19 mM). The detection limit measured was 0.02 mM. These Michaelis-Menten constant K M results demonstrate that zinc oxide nanostructures have potential applications in biosensors. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] An electrochemical biosensor with nanointerface for lactate detection based on lactate dehydrogenase immobilized on zinc oxide nanorods
    Nesakumar, Noel
    Thandavan, Kavitha
    Sethuraman, Swaminathan
    Krishnan, Uma Maheswari
    Rayappan, John Bosco Balaguru
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2014, 414 : 90 - 96
  • [32] Microelectrode glucose biosensor based on nanoporous platinum/graphene oxide nanostructure for rapid glucose detection of tomato and cucumber fruits
    Wu, Binfang
    Xu, Haitao
    Shi, Yufeng
    Yao, Zhijie
    Yu, Jiayu
    Hua, Hua
    Li, Yunpeng
    Chen, Qiulan
    Long, Yongbing
    FOOD QUALITY AND SAFETY, 2022, 6
  • [33] Low-potential detection of glucose with a biosensor based on the immobilization of glucose oxidase on polymer/manganese oxide layered nanocomposite
    Xu, Jing-Juan
    Feng, Jiu-Ju
    Zhong, Xue
    Chen, Hong-Yuan
    ELECTROANALYSIS, 2008, 20 (05) : 507 - 512
  • [34] Microelectrode glucose biosensor based on nanoporous platinum/graphene oxide nanostructure for rapid glucose detection of tomato and cucumber fruits
    Wu, Binfang
    Xu, Haitao
    Shi, Yufeng
    Yao, Zhijie
    Yu, Jiayu
    Zhou, Hua
    Li, Yunpeng
    Chen, Qiulan
    Long, Yongbing
    FOOD QUALITY AND SAFETY, 2022, 6
  • [35] Ultra-miniaturized Glucose Biosensor Using Zinc Oxide Nanorod-based Field Effect Transistor
    Zong, Xianli
    Zhang, Zhizhong
    Zhu, Rong
    2017 IEEE SENSORS, 2017, : 1389 - 1391
  • [36] Photoelectrochemical acetylcholinesterase biosensor incorporating zinc oxide nanoparticles
    Guan Huanan
    Chi Defu
    Yu Jia
    ENVIRONMENTAL BIOTECHNOLOGY AND MATERIALS ENGINEERING, PTS 1-3, 2011, 183-185 : 1701 - 1706
  • [37] Miniaturized ECL detection system for glucose biosensor
    Kang, MS
    Yoo, KP
    Hong, SI
    Min, NK
    2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology, 2005, : 229 - 232
  • [38] Microwave-Based Biosensor for Glucose Detection
    Salim, N. S. M.
    Khalid, K.
    Yusof, N. A.
    PROGRESS OF PHYSICS RESEARCH IN MALAYSIA, PERFIK2009, 2010, 1250 : 401 - +
  • [39] A Study of Biodegradable Biosensor Applied in Glucose Detection
    He, Xin-Xin
    Chen, Ching-Jung
    Liu, Jen-Tsai
    Chang, Shwu-Jen
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 373 - 374
  • [40] Nanoporous cerium oxide thin film for glucose biosensor
    Saha, Shibu
    Arya, Sunil K.
    Singh, S. P.
    Sreenivas, K.
    Malhotra, B. D.
    Gupta, Vinay
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 2040 - 2045