A novel Fe-hemin-metal organic frameworks supported on chitosan-reduced graphene oxide for real-time monitoring of H2O2 released from living cells

被引:30
|
作者
Zhao, Peng [1 ]
Chen, Sha [1 ]
Zhou, Jun [2 ]
Zhang, Suyi [2 ]
Huo, Danqun [1 ]
Hou, Changjun [1 ,3 ]
机构
[1] Chongqing Univ, Coll Bioengn, Key Lab Biorheol Sci & Technol, Minist Educ, Chongqing 400044, Peoples R China
[2] Sichuan Univ Sci & Engn, Coll Bioengn, Liquor Making Biol Technol & Applicat Key Lab Sic, Zigong 643000, Peoples R China
[3] Chongqing Univ, Sch Microelect & Commun Engn, Chongqing Key Lab Biopercept & Intelligent Inform, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
Fe-hemin-Metal organic frameworks; Electrochemical sensor; Hydrogen peroxide; Living cells; HYDROGEN-PEROXIDE; ELECTROCHEMICAL DETECTION; QUADRUPLEX DNAZYME; SENSING PLATFORM; OXIDATIVE BURST; OILSEED RAPE; CARBON; SENSOR; NANOCOMPOSITES; PERFORMANCE;
D O I
10.1016/j.aca.2020.06.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, a kind of novel hemin-based metal organic frameworks (Fe-hemin-MOFs) with unique peroxidase-like bioactivity was developed for the first time. The synthesized Fe-hemin-MOFs exhibited satisfactory catalytic activity toward hydrogen peroxide (H2O2). When it was further supported on Chitosan-reduced graphene oxide (CS-rGO), amplified electrochemical signal could be obtained. The Fe-hemin-MOFs/CS-rGO composite was used to construct a novel H2O2 electrochemical sensor. The elec-trocatalytic reduction of H2O2 displayed two segments linearity range from 1 to 61 mM and 61-1311 mM, as well as a low detection limit of 0.57 mM. Furthermore, the proposed sensor was successfully used for real-time monitoring of H2O2 released from living cells, which extended the practical application of MOFs-based sensors in monitoring the pathological process in living cells. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 98
页数:9
相关论文
共 50 条
  • [41] Laser-assembled conductive 3D nanozyme film-based nitrocellulose sensor for real-time detection of H2O2 released from cancer cells
    Bukhari, Qurat U. A.
    Della Pelle, Flavio
    Alvarez-Diduk, Ruslan
    Scroccarello, Annalisa
    Nogues, Carme
    Careta, Oriol
    Compagnone, Dario
    Merkoci, Arben
    BIOSENSORS & BIOELECTRONICS, 2024, 262
  • [42] Non-enzymatic screen-printed sensor based on PtNPs@polyazure A for the real-time tracking of the H2O2 secreted from living plant cells
    Jimenez-Perez, Rebeca
    Almagro, Lorena
    Isabel Gonzalez-Sanchez, Maria
    Angeles Pedreno, Maria
    Valero, Edelmira
    BIOELECTROCHEMISTRY, 2020, 134 (134)
  • [43] Facile Solvothermal Preparation of Mn2CuO4 Microspheres: Excellent Electrocatalyst for Real-Time Detection of H2O2 Released from Live Cells (vol 10, pg 43543, 2018)
    Balasubramanian, Paramasivam
    Annalakshmi, Muthaiah
    Chen, Shen-Ming
    Sathesh, Tamilarasan
    Peng, Tie-Kun
    Balamurugan, T. S. T.
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (20) : 24067 - 24068
  • [44] Removal of miconazole from water by O3, UV/H2O2 and electrochemical advanced oxidation: Real-time process monitoring and degradation pathway elucidation
    de Souza, Allisson Barros
    Mielcke, Joerg
    Ali, Izba
    Dewil, Raf
    van de Goor, Tom
    Cabooter, Deirdre
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (03):
  • [45] Real-Time H2O2 Measurements in Bone Marrow Mesenchymal Stem Cells (MSCs) Show Increased Antioxidant Capacity in Cells From Osteoporotic Women
    Roman, Flavia
    Urra, Carla
    Porras, Omar
    Pino, Ana Maria
    Rosen, Clifford J.
    Rodriguez, Juan Pablo
    JOURNAL OF CELLULAR BIOCHEMISTRY, 2017, 118 (03) : 585 - 593
  • [46] Electrochemical biosensor based on gold nanoflowers-encapsulated magnetic metal-organic framework nanozymes for drug evaluation with in-situ monitoring of H2O2 released from H9C2 cardiac cells
    Lu, Jing
    Hu, Yuehuai
    Wang, Panxia
    Liu, Peiqing
    Chen, Zuanguang
    Sun, Duanping
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 311 (311):
  • [47] Stretchable and Transparent Electrochemical Sensor Based on Nanostructured Au on Carbon Nanotube Networks for Real-Time Analysis of H2O2 Release from Cells
    Li, Jing
    Jiang, Mengyuan
    Su, Mengjie
    Tian, Liang
    Shi, Weishan
    Yu, Chunmei
    ANALYTICAL CHEMISTRY, 2021, 93 (17) : 6723 - 6730
  • [48] Highly sensitive H2S sensors based on metal-organic framework driven γ-Fe2O3 on reduced graphene oxide composites at room temperature
    Zhang, Chengxin
    Zhang, Shuai
    Yang, Ying
    Yu, Hui
    Dong, Xiangting
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 325
  • [49] Nonenzymatic amperometric sensor for hydrogen peroxide released from living cancer cells based on hierarchical NiCo2O4-CoNiO2 hybrids embedded in partially reduced graphene oxide
    Minghua Wang
    Changbao Wang
    Yongkang Liu
    Bin Hu
    Linghao He
    Yashen Ma
    Zhihong Zhang
    Bingbing Cui
    Miao Du
    Microchimica Acta, 2020, 187
  • [50] Nonenzymatic amperometric sensor for hydrogen peroxide released from living cancer cells based on hierarchical NiCo2O4-CoNiO2hybrids embedded in partially reduced graphene oxide
    Wang, Minghua
    Wang, Changbao
    Liu, Yongkang
    Hu, Bin
    He, Linghao
    Ma, Yashen
    Zhang, Zhihong
    Cui, Bingbing
    Du, Miao
    MICROCHIMICA ACTA, 2020, 187 (08)