Diagnostic Accuracy of Point-of-Care Gastric Ultrasound

被引:90
|
作者
Kruisselbrink, Richelle [1 ,2 ]
Gharapetian, Angineh [1 ,2 ]
Chaparro, Luis E. [2 ]
Ami, Noam [1 ]
Richler, Dustin [1 ]
Chan, Vincent W. S. [1 ,2 ]
Perlas, Anahi [1 ,2 ]
机构
[1] Univ Hlth Network, Toronto Western Hosp, Dept Anesthesia & Pain Management, Toronto, ON, Canada
[2] Univ Toronto, Dept Anesthesia, Toronto, ON, Canada
来源
ANESTHESIA AND ANALGESIA | 2019年 / 128卷 / 01期
关键词
PULMONARY ASPIRATION; SURGICAL-PATIENT; SAMPLE-SIZE; VOLUME; OBESE; ANESTHESIOLOGY; SENSITIVITY; VALIDATION; SONOGRAPHY; MANAGEMENT;
D O I
10.1213/ANE.0000000000003372
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Pulmonary aspiration of gastric contents is associated with significant perioperative morbidity and mortality. Previous studies have investigated the validity, reliability, and possible clinical impact of gastric ultrasound for the assessment of gastric content at the bedside. In the present study, we examined the accuracy (evaluated as sensitivity, specificity, and likelihood ratios) of point-of-care gastric ultrasound to detect a "full stomach" in a simulated scenario of clinical equipoise. METHODS: After a minimum fasting period of 8 hours, 40 healthy volunteers were randomized in a 1:1 ratio to either remain fasted or ingest a standardized quantity of clear fluid or solid. Each subject was randomized twice on 2 independent study sessions at least 24 hours apart. A gastric ultrasound examination was performed by a blinded sonographer following a standardized scanning protocol. Using a combination of qualitative and quantitative findings, the result was summarized in a dichotomous manner as positive (any solid or >1.5 mL/kg of clear fluid) or negative (no solid and <= 1.5 mL/kg of clear fluid) for full stomach. RESULTS: Data from 80 study sessions were analyzed. In this simulated clinical scenario with a pretest probability of 50%, point-of-care gastric ultrasound had a sensitivity of 1.0 (95% confidence interval [CI], 0.925-1.0), a specificity of 0.975 (95% CI, 0.95-1.0), a positive likelihood ratio of 40.0 (95% CI, 10.33-infinity), a negative likelihood ratio of 0 (95% CI, 0-0.072), a positive predictive value of 0.976 (95% CI, 0.878-1.0), and a negative predictive value of 1.0 (95% CI, 0.92-1.0). CONCLUSIONS: Our results suggest that bedside gastric ultrasound is highly sensitive and specific to detect or rule out a full stomach in clinical scenarios in which the presence of gastric content is uncertain.
引用
下载
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [21] DIAGNOSTIC ACCURACY OF POINT-OF-CARE ULTRASOUND FOR INTUSSUSCEPTION PERFORMED BY PEDIATRIC EMERGENCY MEDICINE PHYSICIANS
    Arroyo, Alexander C.
    Zerzan, Jessica
    Vazquez, Hector
    Dickman, Eitan
    Likourezos, Antonios
    Hossain, Rukhsana
    Bonadio, William
    JOURNAL OF EMERGENCY MEDICINE, 2020, 60 (05): : 626 - 632
  • [22] Diagnostic Ultrasound Safety Review for Point-of-Care Ultrasound Practitioners
    Miller, Douglas L.
    Abo, Alyssa
    Abramowicz, Jacques S.
    Bigelow, Timothy A.
    Dalecki, Diane
    Dickman, Eitan
    Donlon, John
    Harris, Gerald
    Nomura, Jason
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (06) : 1069 - 1084
  • [23] Diagnostic Accuracy of Point-of-Care Ultrasound Performed by Pulmonary Critical Care Physicians for the Assessment of the Right Ventricle
    Filopei, Jason
    Acquah, Samuel
    Bondarsky, Eric
    Ramesh, Navitha
    Patrawalla, Paru
    CHEST, 2016, 150 (04) : 657A - 657A
  • [24] The Accuracy of Point-of-Care Ultrasound in the Diagnosis of Acute Cholecystitis
    Wehrle, Chase J.
    Talukder, Asif
    Tien, Lillie
    Parikh, Soham
    Devarakonda, Aditya
    Holsten, Steven B.
    Fox, Elizabeth D.
    Lawson, Andrew
    AMERICAN SURGEON, 2022, 88 (02) : 267 - 272
  • [25] Diagnostic Accuracy of Point-of-Care Tests for Detecting Albuminuria
    McTaggart, Malcolm P.
    Newall, Ronald G.
    Hirst, Jennifer A.
    Bankhead, Clare R.
    Lamb, Edmund J.
    Roberts, Nia W.
    Price, Christopher P.
    ANNALS OF INTERNAL MEDICINE, 2014, 160 (08) : 550 - +
  • [26] Point-of-care ultrasound for preoperative assessment of gastric contents
    Eizaga Rebollar, Ramon
    Delgado Olmos, Irene
    Miralles Aguiar, Francisco
    Torres Morera, Luis Miguel
    ANALES DE PEDIATRIA, 2021, 94 (01): : 57 - 58
  • [27] Test performance of point-of-care ultrasound for gastric content
    Mackenzie, David C.
    Azad, Aftab M.
    Noble, Vicki E.
    Liteplo, Andrew S.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2019, 37 (01): : 123 - 126
  • [28] Diagnostic accuracy of point-of-care ultrasound (PoCUS) for the diagnosis of hip effusion in the pediatric emergency department
    Hadas Katz-Dana
    Rudica Stackievicz
    Elad Dana
    Nir Friedman
    Gali Lackner
    Ehud Rosenbloom
    Ayelet Shles
    Canadian Journal of Emergency Medicine, 2024, 26 (12) : 875 - 882
  • [29] Diagnostic Accuracy of Point-of-Care Lung Ultrasound Among Patients Suspected of Having Pulmonary Tuberculosis
    Babasa, R. B., III
    Partible Bithao, J.
    ANNALS OF EMERGENCY MEDICINE, 2019, 74 (04) : S149 - S149
  • [30] Diagnostic accuracy and clinical utility of point-of-care ultrasound among syncope patients in the emergency department
    Pivetta, E.
    Moretto, F.
    Bianchi, G.
    Masellis, S.
    Bovaro, F.
    Manasievska, M.
    Maule, M. M.
    Lupia, E.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3542 - 3542