Nanoscale in situ observations of crack initiation and propagation in carbon fiber/epoxy composites using synchrotron radiation X-ray computed tomography

被引:31
|
作者
Watanabe, Toshiki [1 ,4 ]
Takeichi, Yasuo [1 ,2 ]
Niwa, Yasuhiro [1 ]
Hojo, Masaki [3 ]
Kimura, Masao [1 ,2 ]
机构
[1] High Energy Accelerator Res Org KEK, Inst Mat Struct Sci, Photon Factory, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
[2] SOKENDAI Grad Univ Adv Studies, Sch High Energy Accelerator Sci, Dept Mat Struct Sci, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
[3] Kyoto Univ, Dept Mech Engn & Sci, Nishikyo Ku, Kyoto 6158540, Japan
[4] Kyoto Univ, Grad Sch Human & Environm Studies, Sakyo Ku, Yoshida Nihonmatsu Cho, Kyoto 6068501, Japan
基金
日本科学技术振兴机构;
关键词
Carbon fibers; Crack; Debonding; Fiber/matrix bond; Nondestructive testing; FIBER-REINFORCED POLYMERS; DISCONTINUOUS INTERLEAVES; DAMAGE SUPPRESSION; FAILURE; CFRP; DEFORMATION; SIMULATION; FATIGUE;
D O I
10.1016/j.compscitech.2020.108244
中图分类号
TB33 [复合材料];
学科分类号
摘要
The crack initiation and propagation under the application of opening load were analyzed in situ using nondestructive synchrotron radiation X-ray computed tomography (nanoscopic SR X-CT) with a spatial resolution of similar to 50 nm. The results show that the voids and cracks initiation are not only the result of local stresses but also are due to two competing nanoscale mechanisms, that is, fiber/plastic interface debonding and in-resin crack initiation. In the "thin" epoxy region in which the resin thickness between the adjacent carbon fibers is small, cracks propagate mainly by debonding along the carbon fiber/epoxy interface. In the "thick" epoxy region in which the resin thickness between the carbon fibers is large, cracks propagate through the extensive plastic deformation of the epoxy resin, and the propagation mechanism largely depends on the resin thickness, which affects the plastic deformation behavior of the epoxy around the crack tip. Voids (sub-mu m) often form in front of the crack tip and merge with the propagating cracks. Nanoscopic SR X-CT provides indispensable information on these nanoscale mechanisms, which cannot be obtained with traditional methods, including macroscopic observations and mechanical theory. These nanoscale mechanisms are essential for the mechanical modeling and analysis at multi scales.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Non-destructive analysis of in situ ammonoid jaws by synchrotron radiation X-ray micro-computed tomography
    Takeda, Yusuke
    Tanabe, Kazushige
    Sasaki, Takenori
    Uesugi, Kentaro
    Hoshino, Masato
    PALAEONTOLOGIA ELECTRONICA, 2016, 19 (03)
  • [42] In situ characterization of nanoscale strains in loaded whole joints via synchrotron X-ray tomography
    Madi, Kamel
    Staines, Katherine A.
    Bay, Brian K.
    Javaheri, Behzad
    Geng, Hua
    Bodey, Andrew J.
    Cartmell, Sarah
    Pitsillides, Andrew A.
    Lee, Peter D.
    NATURE BIOMEDICAL ENGINEERING, 2020, 4 (03) : 343 - +
  • [43] Human thyroid specimen imaging by fluorescent x-ray computed tomography with synchrotron radiation
    Takeda, T
    Yu, QW
    Yashiro, T
    Yuasa, T
    Hasegawa, Y
    Itai, Y
    Akatsuka, T
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 258 - 267
  • [44] X-RAY COMPUTERIZED-TOMOGRAPHY USING MONOCHROMATED SYNCHROTRON RADIATION
    SUZUKI, Y
    USAMI, K
    SAKAMOTO, K
    KOZAKA, H
    HIRANO, T
    SHIONO, H
    KOHNO, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1988, 27 (03): : L461 - L464
  • [45] In Situ Observation of the Microstructure-evolution in Silicon Nitride Ceramics Sintering by Synchrotron Radiation X-ray Computed Tomography
    Xu Feng
    Hu Xiaofang
    Zhao Jianhua
    Yuan Qingxi
    ACTA CHIMICA SINICA, 2009, 67 (11) : 1205 - 1210
  • [46] Fibre failure assessment in carbon fibre reinforced polymers under tensile loading using in situ synchrotron X-ray computed tomography
    Rosini, Sebastian
    Mavrogordato, Mark N.
    Takano, Tsuneo
    Sugiura, Naoki
    Spearing, S. Mark
    Sinclair, Ian
    JOURNAL OF COMPOSITE MATERIALS, 2022, 56 (06) : 825 - 836
  • [47] In-situ analysis of mode I delamination behaviour of carbon fibre/epoxy composites with chopped aramid/flax fiber reinforcement by X-ray micro-computed tomography
    Deng, Yu
    Tu, Haoyun
    Hu, Zhengfei
    COMPOSITES PART B-ENGINEERING, 2025, 297
  • [48] Determination of Density Distribution of Tablets Using Synchrotron X-ray Computed Tomography
    Takayama, Kozo
    Otoguro, Saori
    Okada, Nobuto
    Hoshino, Masato
    Yagi, Naoto
    Obata, Yasuko
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2017, 137 (06): : 757 - 762
  • [49] Combined X-ray fluorescence and absorption computed tomography using a synchrotron beam
    Hall, C.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [50] New types of X-ray computed tomography (CT) with synchrotron radiation: Fluorescent X-ray CT and phase-contrast X-ray CT using interferometer
    Takeda, T
    Momose, A
    Yu, QW
    Yuasa, T
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    CELLULAR AND MOLECULAR BIOLOGY, 2000, 46 (06) : 1077 - 1088