关键词
Coronary artery disease; Drug-eluting stents; Biolimus A9; Optical coherence tomography; Interventional ultrasound; Coronary angiography; SIROLIMUS-ELUTING STENTS; QUANTITATIVE CORONARY-ANGIOGRAPHY; BARE-METAL STENTS; BIODEGRADABLE POLYMER; DURABLE POLYMER; INTRAVASCULAR ULTRASOUND; ARTERY-DISEASE; IMPLANTATION; OUTCOMES; LEADERS;
D O I
10.1007/s10554-013-0188-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
First generation drug-eluting stents (DES) are associated with reduced in-stent restenosis but significant increased risk of very late stent thrombosis (VLST). The absence of polymer in DES systems may reduce the occurrence of VLST. Optic coherence tomography (OCT) has been used for stent analysis as a surrogate safety endpoint. This study aimed to assess the long-term follow up of strut apposition and tissue coverage of BioMatrix (TM) DES by OCT. 20 patients undergoing BioMatrix (TM) DES (n = 15) or S-Stent (TM) BMS (n = 5) implantation were followed for at least 5 years and evaluated by quantitative coronary angiography, intravascular ultrasound, and OCT. The difference between the stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by Fisher exact test. Rates of in-stent late loss were similar between groups [0.40 (0.21;0.77) vs. 0.68 (0.66; 0.82) mm, p = 0.205, for BioMatrix (TM) and S-Stent (TM), respectively]. The vessel, stent and lumen volumes did not differ between groups. Patients treated with BioMatrix (TM) had significantly less stent obstruction [5.6 (4.4;9.7) vs. 28.6 (24.7;29.0) %, p = 0.001]. OCT analysis of 12 stents (Biomatrix (TM) = 9 and S-Stent (TM) = 3) demonstrated 126 (8.7 %) uncovered struts in the BioMatrix (TM) group compared to 23 (4.0 %) in the S-Stent (TM) group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6 %) struts in the DES and 2 (0.4 %) struts in the BMS groups were simultaneously uncovered and malapposed (p = 0.924). BioMatrix (TM) DES was associated with lower rates of in-stent obstruction, and similar percentage of neointimal coverage on struts and of complete strut apposition.
引用
收藏
页码:977 / 988
页数:12
相关论文
共 50 条
  • [21] Reproducibility of intra-coronary optical coherence tomography-derived measurements of stent strut apposition and tissue coverage
    Barlis, P.
    Dimopoulos, K.
    Tanigawa, J.
    Dzielicka, E.
    Del Furia, F.
    Ferrante, G.
    Aguiar-Souto, P.
    D'Souza, S.
    Di Mario, C.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 845 - 845
  • [22] Randomised comparison of strut coverage between Nobori biolimus-eluting and sirolimus-eluting stents: an optical coherence tomography analysis
    Kim, Byeong-Keuk
    Ha, Jinyong
    Mintz, Gary S.
    Kim, Jung-Sun
    Shin, Dong-Ho
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. EUROINTERVENTION, 2014, 9 (12) : 1389 - 1397
  • [23] Long-term Vascular Response to Biodegradable Polymer Biolimus-Eluting Stents in Comparison With Durable Polymer Sirolimus-Eluting Stents and Bare-Metal Stents: Five-year Follow-up Optical Coherence Tomography Study
    Kuramitsu, Shoichi
    Sonoda, Shinjo
    Domei, Takenori
    Shirai, Shinichi
    Ando, Kenji
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B112 - B112
  • [24] Evaluation of long-term changes of neointimal coverage on sirolimus-eluting stents by optical coherence tomography
    Daisuke, Matsumoto
    Junya, Shite
    Toshiro, Shinke
    Hiromasa, Otake
    Daisuke, Ogasawara
    Yusuke, Tanino
    Takahiro, Sawada
    Mitsuhiro, Yokoyama
    [J]. CIRCULATION, 2006, 114 (18) : 645 - 645
  • [26] Long Term Follow-Up of Neointimal Coverage after Silorimus-Eluting Stent Implantation -Optical Coherence Tomography Study
    Ishigami, Enichi
    Uemura, Shiro
    Morikawa, Yoshinobu
    Soeda, Tsunenari
    Okayama, Satoshi
    Takemoto, Yasuhiro
    Kawata, Hiroyuki
    Horii, Manabu
    Saito, Yoshihiko
    [J]. CIRCULATION, 2008, 118 (18) : S961 - S961
  • [27] Long-term coronary arterial response to biodegradable polymer biolimus-eluting stents in comparison with durable polymer sirolimus-eluting stents and bare-metal stents: Five-year follow-up optical coherence tomography study
    Kuramitsu, Shoichi
    Sonoda, Shinjo
    Yokoi, Hiroyoshi
    Iwabuchi, Masashi
    Nishizaki, Yuji
    Shinozaki, Tomohiro
    Domei, Takenori
    Hyodo, Makoto
    Inoue, Katsumi
    Shirai, Shinichi
    Ando, Kenji
    Nobuyoshi, Masakiyo
    [J]. ATHEROSCLEROSIS, 2014, 237 (01) : 23 - 29
  • [28] PTCA IN THE VERY ELDERLY - LONG-TERM FOLLOW-UP
    JENKINS, GM
    MIDEI, MG
    DOWGER, B
    WALFORD, GD
    AVERSANO, T
    GOTTLIEB, S
    BRINKER, JA
    [J]. CIRCULATION, 1990, 82 (04) : 739 - 739
  • [29] Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography
    Matsumoto, Daisuke
    Shite, Junya
    Shinke, Toshiro
    Otake, Hiromasa
    Tanino, Yusuke
    Ogasawara, Daisuke
    Sawada, Takahiro
    Paredes, Oscar Luis
    Hirata, Ken-ichi
    Yokoyama, Mitsuhiro
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 (08) : 961 - 967
  • [30] 2 years long-term follow-up optical coherence tomographic findings compared with 9 months after implantation of everolimus-eluting stents
    Lee, Jun-Won
    Youn, Young Jin
    Kim, Woo-Taek
    Alm, Sung-Gyun
    Ahn, Min-Soo
    Kim, Jang-Young
    Yoo, Byung-Su
    Lee, Seung-Hwan
    Yoon, Junghan
    Choe, Kyung-Hoon
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B184 - B185