Very long-term follow-up of strut apposition and tissue coverage with Biolimus A9 stents analyzed by optical coherence tomography

被引:4
|
作者
Staico, Rodolfo [1 ]
Costa, Marco A. [2 ]
Chamie, Daniel [2 ]
Bezerra, Hiram [2 ]
Armaganijan, Luciana V. [1 ]
Costa, Ricardo A. [1 ]
Costa, Jose Ribamar [1 ]
Siqueira, Dimytri [1 ]
Centemero, Marinella [1 ]
Chaves, Aurea [1 ]
Tanajura, Luiz Fernando [1 ]
Abizaid, Alexandre [1 ]
Feres, Fausto [1 ]
Sousa, J. Eduardo M. R. [1 ]
Sousa, Amanda G. M. R. [1 ]
机构
[1] Dante Pazzanese Inst Cardiol, BR-04012180 Sao Paulo, Brazil
[2] Case Western Reserve Univ, Cleveland, OH 44106 USA
来源
关键词
Coronary artery disease; Drug-eluting stents; Biolimus A9; Optical coherence tomography; Interventional ultrasound; Coronary angiography; SIROLIMUS-ELUTING STENTS; QUANTITATIVE CORONARY-ANGIOGRAPHY; BARE-METAL STENTS; BIODEGRADABLE POLYMER; DURABLE POLYMER; INTRAVASCULAR ULTRASOUND; ARTERY-DISEASE; IMPLANTATION; OUTCOMES; LEADERS;
D O I
10.1007/s10554-013-0188-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
First generation drug-eluting stents (DES) are associated with reduced in-stent restenosis but significant increased risk of very late stent thrombosis (VLST). The absence of polymer in DES systems may reduce the occurrence of VLST. Optic coherence tomography (OCT) has been used for stent analysis as a surrogate safety endpoint. This study aimed to assess the long-term follow up of strut apposition and tissue coverage of BioMatrix (TM) DES by OCT. 20 patients undergoing BioMatrix (TM) DES (n = 15) or S-Stent (TM) BMS (n = 5) implantation were followed for at least 5 years and evaluated by quantitative coronary angiography, intravascular ultrasound, and OCT. The difference between the stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by Fisher exact test. Rates of in-stent late loss were similar between groups [0.40 (0.21;0.77) vs. 0.68 (0.66; 0.82) mm, p = 0.205, for BioMatrix (TM) and S-Stent (TM), respectively]. The vessel, stent and lumen volumes did not differ between groups. Patients treated with BioMatrix (TM) had significantly less stent obstruction [5.6 (4.4;9.7) vs. 28.6 (24.7;29.0) %, p = 0.001]. OCT analysis of 12 stents (Biomatrix (TM) = 9 and S-Stent (TM) = 3) demonstrated 126 (8.7 %) uncovered struts in the BioMatrix (TM) group compared to 23 (4.0 %) in the S-Stent (TM) group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6 %) struts in the DES and 2 (0.4 %) struts in the BMS groups were simultaneously uncovered and malapposed (p = 0.924). BioMatrix (TM) DES was associated with lower rates of in-stent obstruction, and similar percentage of neointimal coverage on struts and of complete strut apposition.
引用
收藏
页码:977 / 988
页数:12
相关论文
共 50 条
  • [1] Very long-term follow-up of strut apposition and tissue coverage with Biolimus A9 stents analyzed by optical coherence tomography
    Rodolfo Staico
    Marco A. Costa
    Daniel Chamié
    Hiram Bezerra
    Luciana V. Armaganijan
    Ricardo A. Costa
    José Ribamar Costa
    Dimytri Siqueira
    Marinella Centemero
    Áurea Chaves
    Luiz Fernando Tanajura
    Alexandre Abizaid
    Fausto Feres
    J. Eduardo M. R. Sousa
    Amanda G. M. R. Sousa
    [J]. The International Journal of Cardiovascular Imaging, 2013, 29 : 977 - 988
  • [2] Tissue coverage of paclitaxel and sirolimus eluting stents in long term follow-up: Optical coherence tomography study
    Kochman, Janusz
    Pietrasik, Arkadiusz
    Rdzanek, Adam
    Scibisz, Anna
    Pawlak, Maciej
    Filipiak, Krzysztof J.
    Opolski, Grzegorz
    [J]. CARDIOLOGY JOURNAL, 2013, 20 (03) : 247 - 253
  • [3] Long-Term Follow-up of Neointimal Coverage of Sirolimus-Eluting Stents - Evaluation With Optical Coherence Tomography -
    Ishigami, Ken-ichi
    Uemura, Shiro
    Morikawa, Yoshinobu
    Soeda, Tsunenari
    Okayama, Satoshi
    Nishida, Taku
    Takemoto, Yasuhiro
    Onoue, Kenji
    Somekawa, Satoshi
    Takeda, Yukiji
    Kawata, Hiroyuki
    Horii, Manabu
    Saito, Yoshihiko
    [J]. CIRCULATION JOURNAL, 2009, 73 (12) : 2300 - 2307
  • [4] The Relationship Between Post-Stent Strut Apposition and Follow-Up Strut Coverage Assessed by a Contour Plot Optical Coherence Tomography Analysis
    Kim, Jung-Sun
    Ha, Jinyong
    Kim, Byeong-Keuk
    Shin, Dong-Ho
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 641 - 651
  • [5] Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography
    Li, Shan
    Gai, Luyue
    Yang, Tingshu
    Zhang, Li
    Xu, Xiuli
    Bai, Qicai
    Xu, Hang
    Wang, Yutang
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 768 - 775
  • [6] Optical coherence tomography analysis of strut coverage in biolimus- and sirolimus-eluting stents: 3-Month and 12-month serial follow-up
    Kim, Byeong-Keuk
    Hong, Myeong-Ki
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (05) : 4617 - 4623
  • [7] Long-term follow-up of drug-eluting stents (DES) optical coherence tomography (OCT) findings
    Regar, E.
    Ong, A. T.
    Mc Fadden, E. P.
    de Jaegere, P. T. T.
    van Beusekom, H. M. M.
    van der Giessen, W. J.
    de Feyter, P.
    Serruys, P. W.
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 : 713 - 713
  • [8] Comparison of neointimal coverage of biolimus A9 eluting stents and paclitaxel eluting stents using optical coherence tomography at 6 months after implantation
    Mavronasiou, E.
    Karantalis, V.
    Davlouros, P.
    Xanthopoulou, I.
    Nikokiris, G.
    Mitropoulou, G.
    Damelou, A.
    Tsigkas, G.
    Hahalis, G.
    Alexopoulos, D.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 995 - 995
  • [9] Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage
    Barlis, Peter
    Dimopoulos, Konstantinos
    Tanigawa, Jun
    Dzielicka, Ewa
    Ferrante, Giuseppe
    Del Furia, Francesca
    Di Mario, Carlo
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 141 (02) : 151 - 156
  • [10] Evaluation of Neointimal Coverage of Long-term Follow-up Evaluation after Sirolimus-Eluting Stents and Paclitaxel-eluting Stents Implantation by Optical Coherence Tomography
    Zhao, Min
    Minners, Jan
    Comberg, Thomas
    Gick, Micheal
    Werner, Klaus
    Buettner, Achim
    Neumann, Franz-Josef
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A88 - A88