Contribution of Fourier-domain optical coherence tomography to the diagnosis of keratoconus progression

被引:6
|
作者
Ouanezar, Sofiane [1 ]
Sandali, Otman [1 ]
Atia, Raphael [1 ]
Temstet, Cyrille [1 ]
Georgeon, Cristina [1 ]
Laroche, Laurent [1 ,2 ]
Borderie, Vincent [1 ,2 ]
Bouheraoua, Nacim [1 ,2 ]
机构
[1] UPMC Sorbonne Univ, Quinze Vingts Natl Ophthalmol Hosp, 28 Rue Charenton, F-75012 Paris, France
[2] UPMC Sorbonne Univ, Inst Vis, INSERM, UMR S968, Paris, France
来源
关键词
COLLAGEN CROSS-LINKING; ORBSCAN-II; CORNEAL ECTASIA; PENTACAM HR; REPEATABILITY; ANTERIOR; REFRACTION; AGREEMENT;
D O I
10.1016/j.jcrs.2018.09.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the anatomic criteria for diagnosing keratoconus progression by corneal optical coherence tomography (OCT). Setting: Quinze-Vingts National Ophthalmology Hospital, Paris, France. Design: Prospective case series. Methods: Scanning-slit corneal topography (Orbscan II) and Fourier-domain corneal OCT (RTVue) were performed in eyes with mild to moderate keratoconus (progressive or nonprogressive [stable] ectasia) at each examination to assess the keratoconus. Disease progression was defined as an increase of at least 1.0 diopter (D) in the steepest keratometry (K) measurement over 6 months. Results: Of the 134 eyes of 134 patients with mild to moderate keratoconus, 98 had had progressive ectasia and 36 nonprogressive ectasia. The mean maximum K increased significantly in the progressive group (2.1 D +/- 1.2 [SD], P < .0001) and remained constant in the stable group (-0.03 +/- 0.39 D, P = .31). The mean thinnest corneal thickness increased significantly in the progressive group (-7.98 +/- 9.3 mu m, P < .0001) and remained constant in the stable group (-0.52 +/- 4.21 mu m, P = .22). The change in maximum K was significantly correlated with changes in the thinnest corneal thickness (r = -0.61, P < .0001). A cutoff value of -5 mu m for the change in thinnest corneal thickness was identified on receiver operating characteristic curves as a threshold separating cases of progressive and stable keratoconus (area under the curve, 0.79; sensitivity, 68%; specificity, 89%). Conclusions: Topographic data partly reflected the structural changes occurring during the progression of corneal ectasia. Based on the pachymetric parameters provided by OCT, corneal and epithelial thinning was correlated with corneal deformation. The use of corneal OCT might therefore improve the diagnostic sensitivity for keratoconus progression. (C) 2018 ASCRS and ESCRS
引用
收藏
页码:159 / 166
页数:8
相关论文
共 50 条
  • [1] Diagnosis of keratoconus progression by Fourier-domain optical coherence tomography should be correlated with Scheimpflug tomography
    Agrawal, Swati
    Khurana, Ashi
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1523 - 1523
  • [2] Tear Meniscus Analysis with Fourier-Domain Optical Coherence Tomography in Keratoconus
    Sarac, Ozge
    Soyugelen, Gulizar
    Gurdal, Canan
    Bostanci-Ceran, Basak
    Can, Izzet
    [J]. CURRENT EYE RESEARCH, 2011, 36 (06) : 528 - 533
  • [3] Fourier-Domain Optical Coherence Tomography Imaging in Keratoconus A Corneal Structural Classification
    Sandali, Otman
    El Sanharawi, Mohamed
    Temstet, Cyril
    Hamiche, Taous
    Galan, Alice
    Ghouali, Wajdene
    Goemaere, Isabelle
    Basli, Elena
    Borderie, Vincent
    Laroche, Laurent
    [J]. OPHTHALMOLOGY, 2013, 120 (12) : 2403 - 2412
  • [4] Fourier phase in Fourier-domain optical coherence tomography
    Uttam, Shikhar
    Liu, Yang
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (12) : 2286 - 2306
  • [5] Pachymetric mapping with Fourier-domain optical coherence tomography
    Li, Yan
    Tang, Maolong
    Zhang, Xinbo
    Salaroli, Camila H.
    Ramos, Jose L.
    Huang, David
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05): : 826 - 831
  • [6] Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography in the Measurement of Thinnest Corneal Thickness in Keratoconus
    Wang, Chunxiao
    Xia, Xueying
    Tian, Bishan
    Zhou, Shiyou
    [J]. JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [7] Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconus
    Szalai, Eszter
    Berta, Andras
    Hassan, Ziad
    Modis, Laszlo, Jr.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (03): : 485 - 494
  • [8] Time-domain interpolation for Fourier-domain optical coherence tomography
    Zhang, Yudong
    Li, Xiqi
    Wei, Ling
    Wang, Kai
    Ding, Zhihua
    Shi, Guohua
    [J]. OPTICS LETTERS, 2009, 34 (12) : 1849 - 1851
  • [9] Characterization of coated optical fibers by Fourier-domain optical coherence tomography
    Jasapara, J
    Wielandy, S
    [J]. OPTICS LETTERS, 2005, 30 (09) : 1018 - 1020
  • [10] Macular thickness of Chinese with fourier-domain optical coherence tomography
    Yu Weihong
    Zheng Lin
    Dai Rongping
    Zhang Zhiqiao
    Dong Fangtian
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (01) : E104 - E105