摘要
During an ultrasound scan, contact between the probe and the skin deforms the underlying tissue. This can be considered a feature (as in elastography), but is in general undesirable, particularly, for 3D scanning, In this paper we propose a novel system to correct this deformation by measuring the contact force at the time of the ultrasound scan and then using an elastic model to predict the tissue deformation. The inverse of this deformation is then applied to the image, generating the image that would have been seen had there been no contact with the probe. A prototype system has been implemented using an a priori finite element model to predict the deformation, This has been tested on gelatine phantoms and shown to remove the contact deformation and so give improved 3D reconstructions.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [1] Trajectory-based Deformation Correction in Ultrasound Images
    Sun, Shih-Yu
    Anthony, Brian W.
    Gilbertson, Matthew W.
    [J]. MEDICAL IMAGING 2010: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2010, 7629
  • [2] Use the force: deformation correction in robotic 3D ultrasound
    Virga, Salvatore
    Goebl, Rudiger
    Baust, Maximilian
    Navab, Nassir
    Hennersperger, Christoph
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (05) : 619 - 627
  • [3] Use the force: deformation correction in robotic 3D ultrasound
    Salvatore Virga
    Rüdiger Göbl
    Maximilian Baust
    Nassir Navab
    Christoph Hennersperger
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2018, 13 : 619 - 627
  • [4] Contact localization using force/torque measurements
    Zhou, XC
    Shi, Q
    Li, ZX
    [J]. 1996 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, PROCEEDINGS, VOLS 1-4, 1996, : 1339 - 1344
  • [5] A system for simultaneously measuring contact force, ultrasound, and position information for use in force-based correction of freehand scanning
    Burcher, MR
    Noble, JA
    Han, LH
    Gooding, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (08) : 1330 - 1342
  • [6] Phase aberration correction using ultrasound radiation force and vibrometry optimization
    Urban, Matthew W.
    Bernal, Miguel
    Greenleaf, James F.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (06) : 1142 - 1153
  • [7] Phase Aberration Correction using Ultrasound Radiation Force and Vibrometry Optimization
    Urban, Matthew W.
    Restrepo, Miguel Bernal
    Greenleaf, James F.
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 132 - 135
  • [8] Minimising the effect of nanoparticle deformation in intermittent contact amplitude modulation atomic force microscopy measurements
    Babic, Bakir
    Lawn, Malcolm A.
    Coleman, Victoria A.
    Jamting, Asa K.
    Herrmann, Jan
    [J]. JOURNAL OF APPLIED PHYSICS, 2016, 119 (21)
  • [9] Minimising the effect of nanoparticle deformation in intermittent contact amplitude modulation atomic force microscopy measurements
    Babic, Bakir
    Lawn, Malcolm A.
    Coleman, Victoria A.
    Jämting, Åsa K.
    Herrmann, Jan
    [J]. Journal of Applied Physics, 2016, 119 (21):
  • [10] Author Correction: The liberating force of ultrasound
    Roman Boulatov
    [J]. Nature Chemistry, 2021, 13 (7) : 714 - 714