Validation of 68Ge/68Ga generator processing by chemical purification for routine clinical application of 68Ga-DOTATOC

被引:88
|
作者
Asti, Mattia [1 ]
De Pietri, Giovanni [1 ]
Fraternali, Alessandro [1 ]
Grassi, Elisa [2 ]
Sghedoni, Roberto [2 ]
Floroni, Federica [2 ]
Roesch, Frank [3 ]
Versari, Annibale [1 ]
Salvo, Diana [1 ]
机构
[1] Santa Maria Nuova Hosp, Dept Nucl Med, Reggio Emilia, Italy
[2] Santa Maria Nuova Hosp, Dept Med Phys, Reggio Emilia, Italy
[3] Johannes Gutenberg Univ Mainz, Inst Nucl Chem, D-55128 Mainz, Germany
关键词
Ge-68/Ga-68; generator; postprocessing of eluates; cation-exchange chromotography; DOTATOC; PET;
D O I
10.1016/j.nucmedbio.2008.04.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Imaging of somatostatin receptor expressing tumors has been greatly enhanced by the use of Ga-68-DOTATOC and PET/CT. Methods: In this work, a purification method for the Ge-68/Ge-68 generator eluate and a method to produce Ga-68-DOTATOC suitable for clinical use were evaluated. The generator eluate was purified and concentrated on a cation-exchange cartridge in HCl/acetone media. The efficacy of this procedure in eliminating metal impurities from the Ga-68 soultion was investigated by ICP-Ms. The radiotracer quality was evaluated by radio-TLC, and gamma-ray spectrometry. Resutls: Ga-68-DOTATOC preparations (n=33) were carried out with a mean synthesis yield of 59.3 +/- 2.8% (not corrected for decay) and a batch activity ranging from >95% of the Fe(III), Zn(II) and Mn(II) were eliminated from the solution. Conclusions: Ga-68-DOTATOC produced with this method can be efficiently used in nuclear medicine departments for PET evaluations. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 724
页数:4
相关论文
共 50 条
  • [21] The 68Ge/68Ga generator has high potential, but when can we use 68Ga-labelled tracers in clinical routine?
    Breeman, Wouter A. P.
    Verbruggen, Alfons M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (07) : 978 - 981
  • [22] The 68Ge/68Ga generator has high potential, but when can we use 68Ga-labelled tracers in clinical routine?
    Wouter A. P. Breeman
    Alfons M. Verbruggen
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 978 - 981
  • [23] Quantitative online isolation of 68Ge from 68Ge/68Ga generator eluates for purification and immediate quality control of breakthrough
    Eppard, Elisabeth
    Loktionova, Natalia S.
    Roesch, Frank
    APPLIED RADIATION AND ISOTOPES, 2013, 82 : 45 - 48
  • [24] Instantaneous quantitative determination of 68Ge breakthrough of 68Ge/68Ga generators
    Roesch, Frank
    Loktionova, Natalia
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [25] 68Ge/68Ga generators and tracer production
    Velikyan, I.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56
  • [26] Preparation of 68Ge/68Ga generator with a binary Ga/Ag electrodepositions as solid target
    Cheng, WL
    Jao, Y
    Lee, CS
    Lo, AR
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 245 (01) : 25 - 30
  • [27] Preparation of 68Ge/68Ga Generator with a Binary Ga/Ag Electrodepositions as Solid Target
    Wu-Long Cheng
    Yun Jao
    Chung-Shin Lee
    Ai-Ren Lo
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 245 : 25 - 30
  • [28] PROCESSING OF 68Ge/68Ga GENERATOR ELUATES FOR LABELING OF BIOMOLECULES VIA BIFUNCTIONAL CHELATORS
    Zhernosekov, K. P.
    Filosofov, D. V.
    Jahn, M.
    Jennewein, M.
    Roesch, F.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2005, 48 : S188 - S188
  • [29] Development of adsorption/desorption material for novel 68Ge/68Ga generator
    Lee, J.
    Park, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S121 - S121
  • [30] A new 68Ge/68Ga generator based on CeO2
    Institute of Nuclear Research, Academia Sinica, Shanghai 201800, China
    J. Radioanal. Nucl. Chem., 4 (233-238):