Surface analysis and corrosion resistance of a new titanium base alloy in simulated body fluids

被引:111
|
作者
Vasilescu, C. [1 ]
Drob, S. I. [1 ]
Neacsu, E. I. [1 ]
Mirza Rosca, J. C. [2 ]
机构
[1] Romanian Acad, Inst Phys Chem Ilie Murgulescu, Bucharest 060021, Romania
[2] Las Palmas de Gran Canaria Univ, Tafira 35017, Spain
关键词
Alloy; Cyclic voltammetry; EIS; XPS; Passive films; RINGERS LACTATE SOLUTION; ELECTROCHEMICAL CORROSION; IMPEDANCE SPECTROSCOPY; TI-15ZR-4NB-4TA ALLOY; CALCIUM-PHOSPHATE; FATIGUE STRENGTH; BEHAVIOR; TI-6AL-4V; TI; TI-13NB-13ZR;
D O I
10.1016/j.corsci.2012.08.042
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new quaternary Ti-20Nb-10Zr-5Ta alloy with 3-near microstructure was obtained. Its native passive film composition and its modification and corrosion resistance after 2000 immersion hours in simulated biofluids were studied. The native film on the alloy surface contains TiO2, Nb2O5, ZrO2, Ta2O5 protective oxides as was demonstrated by XPS. After 2000 h, XPS revealed the presence of same oxides and calcium, phosphorous ions deposited from physiological solutions as hydroxyapatite. In Ringer and Ringer-Brown solutions, the new alloy presented low corrosion rates. Impedance data exhibited a passive film with two layers: an inner, barrier layer and an outer, porous layer. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:431 / 440
页数:10
相关论文
共 50 条
  • [31] Corrosion resistance and biocompatibility of a new porous surface for titanium implants
    Simon, M
    Lagneau, C
    Moreno, J
    Lissac, M
    Dalard, F
    Grosgogeat, B
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2005, 113 (06) : 537 - 545
  • [32] New chemical treatment for bioactive titanium alloy with high corrosion resistance
    S. Spriano
    M. Bronzoni
    F. Rosalbino
    E. Vernè
    Journal of Materials Science: Materials in Medicine, 2005, 16 : 203 - 211
  • [33] Surface Properties and Erosion–Corrosion Behavior of Nanostructured Pure Titanium in Simulated Body Fluid
    Osama M. Irfan
    Fahad A. Al-Mufadi
    F. Djavanroodi
    Metallurgical and Materials Transactions A, 2018, 49 : 5695 - 5704
  • [34] Influence of Tantalum Addition on the Corrosion Passivation of Titanium-Zirconium Alloy in Simulated Body Fluid
    Sherif, El-Sayed M.
    Bahri, Yassir A. A.
    Alharbi, Hamad F. F.
    Ijaz, Muhammad Farzik
    Alnaser, Ibrahim A. A.
    MATERIALS, 2022, 15 (24)
  • [35] New chemical treatment for bioactive titanium alloy with high corrosion resistance
    Spriano, S
    Bronzoni, M
    Rosalbino, F
    Vernè, E
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2005, 16 (03) : 203 - 211
  • [36] Corrosion behavior of plasma electrolytically oxidized gamma titanium aluminide alloy in simulated body fluid
    Rodriguez, L. Lara
    Sundaram, P. A.
    MATERIALS CHEMISTRY AND PHYSICS, 2016, 181 : 67 - 77
  • [37] In Vitro Corrosion Resistance of Ta2N Nanocrystalline Coating in Simulated Body Fluids
    Xu Jiang
    Bao Xike
    Jiang Shuyun
    ACTA METALLURGICA SINICA, 2018, 54 (03) : 443 - 456
  • [38] Corrosion Resistance of Passivated NiTi After Long-Term Exposure to Simulated Body Fluids
    Kaczmarek, Marcin
    Kurtyka, Przemyslaw
    Paszenda, Zbigniew
    INNOVATIONS IN BIOMEDICAL ENGINEERING, 2019, 925 : 301 - 311
  • [39] CORROSION RESISTANCE IMPROVEMENT OF TITANIUM BASE ALLOYS
    Popa, Mihai V.
    Vasilescu, Ecaterina
    Drob, Paula
    Vasilescu, Cora
    Drob, Silviu I.
    Mareci, Daniel
    Mirza Rosca, Julia C.
    QUIMICA NOVA, 2010, 33 (09): : 1892 - 1896
  • [40] Investigation on the Corrosion Resistance of T4C Titanium Alloy in Simulated Oilfield Solution
    Lu, Xiang-hong
    Zhang, Xin-xin
    Li, Hong-fu
    Chen, Long
    Wang, Chen
    Li, Jian
    Liu, Yan-ming
    Li, Ning
    Deng, Jing-yu
    Zheng, Wen -long
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (12):