Ultrahigh resolution optical coherence tomography using a superluminescent light source

被引:70
|
作者
Kowalevicz, AM [1 ]
Ko, T
Hartl, I
Fujimoto, JG
Pollnau, M
Salathé, RP
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] Swiss Fed Inst Technol, Inst Appl Opt, Dept Microtech, CH-1015 Lausanne, Switzerland
[4] Harvard Univ, Div Engn & Appl Sci, Cambridge, MA 02138 USA
来源
OPTICS EXPRESS | 2002年 / 10卷 / 07期
关键词
D O I
10.1364/OE.10.000349
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A superluminescent Ti: Al2O3 crystal is demonstrated as a light source for ultrahigh resolution optical coherence tomography (OCT). Single spatial mode, fiber coupled output powers of similar to40 muW can be generated with 138 nm bandwidth using a 5 W frequency doubled, diode pumped laser, pumping a thin Ti: Al2O3 crystal. Ultrahigh resolution OCT imaging is demonstrated with 2.2 mum axial resolution in air, or 1.7 mum in tissue, with >86 dB sensitivity. This light source provides a simple and robust alternative to femtosecond lasers for ultrahigh resolution OCT imaging. (C) 2002 Optical Society of America.
引用
收藏
页码:349 / 353
页数:5
相关论文
共 50 条
  • [1] Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source
    Ko, TH
    Adler, DC
    Fujimoto, JG
    Mamedov, D
    Prokhorov, V
    Shidlovski, V
    Yakubovich, S
    [J]. OPTICS EXPRESS, 2004, 12 (10): : 2112 - 2119
  • [2] Ultrahigh resolution spectral-domain optical coherence tomography at 1.3 μm using a broadband superluminescent diode light source
    Bayleyegn, Masreshaw D.
    Makhlouf, Houssine
    Crotti, Caroline
    Plamann, Karsten
    Dubois, Arnaud
    [J]. OPTICS COMMUNICATIONS, 2012, 285 (24) : 5564 - 5569
  • [3] Ultrahigh resolution optical coherence tomography at two infrared wavelength regions using a single light source
    Spoeler, Felix
    Kray, Stefan
    Grychtol, Patrik
    Hermes, Barbara
    Bornemann, Joerg
    Foerst, Michael
    Kurz, Heinrich
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES III, 2007, 6627
  • [4] Broadband superluminescent diode-based ultrahigh resolution optical coherence tomography for ophthalmic imaging
    Zhu, Dexi
    Shen, Meixiao
    Jiang, Hong
    Li, Ming
    Wang, Michael R.
    Wang, Yuhong
    Ge, Lili
    Qu, Jia
    Wang, Jianhua
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (12)
  • [5] Broadband light source based on quantum-well superluminescent diodes for high-resolution optical coherence tomography
    Adler, DS
    Ko, TH
    Konorev, AK
    Mamedov, DS
    Prokhorov, VV
    Fujimoto, JJ
    Yakubovich, SD
    [J]. QUANTUM ELECTRONICS, 2004, 34 (10) : 915 - 918
  • [6] Optimization of dual-band continuum light source for ultrahigh-resolution optical coherence tomography
    Wang, Hui
    Rollins, Andrew M.
    [J]. APPLIED OPTICS, 2007, 46 (10) : 1787 - 1794
  • [7] All-fiber, CW Raman continuum light source for ultrahigh resolution optical coherence tomography
    Hsiung, PL
    Chen, Y
    Nishizawa, N
    Ko, TH
    Fujimoto, JG
    de Matos, CJS
    Popov, SV
    Taylor, JR
    Broeng, J
    Gapontsev, VP
    [J]. FIBER LASERS II: TECHNOLOGY, SYSTEMS, AND APPLICATIONS, 2005, 5709 : 214 - 221
  • [8] Improvement of axial resolution for optical coherence tomography using a synthesized light source
    Sato, M
    Wakaki, I
    Watanabe, Y
    Tanno, N
    [J]. ROMOPTO 2003: SEVENTH CONFERENCE ON OPTICS, 2004, 5581 : 662 - 669
  • [9] Ultrahigh-Resolution Optical Coherence Tomography with LED-Phosphor-Based Broadband Light Source
    Tsai, Meng-Tsan
    Hung, Jeng-Jie
    Chan, Ming-Che
    [J]. APPLIED PHYSICS EXPRESS, 2013, 6 (12)
  • [10] Ultrahigh-resolution optical coherence tomography
    Drexler, W
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 47 - 74