"Signal-On" electrochemical biosensor based on a competitive immunoassay format for the sensitive determination of oxytetracycline

被引:38
|
作者
Jampasa, Sakda [1 ]
Pummoree, Jirachaya [2 ]
Siangproh, Weena [3 ]
Khongchareonporn, Nanthika [1 ,4 ]
Ngamrojanavanich, Nattaya [1 ,5 ]
Chailapakul, Orawon [5 ]
Chaiyo, Sudkate [1 ,4 ,5 ]
机构
[1] Chulalongkorn Univ, Inst Biotechnol & Genet Engn, Bangkok 10330, Thailand
[2] Srinakharinwirot Univ, Fac Agr Prod Technol & Innovat, Dept Biol & Agr Prod, Bangkok 10110, Thailand
[3] Srinakharinwirot Univ, Fac Sci, Dept Chem, Bangkok 10110, Thailand
[4] Chulalongkorn Univ, Food Risk Hub, Res Unit, Bangkok 10330, Thailand
[5] Chulalongkorn Univ, Electrochem & Opt Spect Ctr Excellence EOSCE, Bangkok 10330, Thailand
关键词
Signal-on electrochemical biosensor; Paper-based analytical device; Competitive immunoassay; Oxytetracycline; LINKED-IMMUNOSORBENT-ASSAY; REDUCED GRAPHENE OXIDE; CARBON NANOTUBE; PRUSSIAN BLUE; DNA SENSOR; TETRACYCLINE; APTASENSOR; RESIDUES; ANTIBODY; ELECTRODES;
D O I
10.1016/j.snb.2020.128389
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we describe a new "signal-on" electrochemical biosensor based on a competitive immunoassay with a label-free format for the facile, sensitive and cost-effective determination of oxytetracycline (OTC). The device pattern was designed and printed on low-cost filter paper to construct a disposable paper-based analytical device (PAD) using a wax printing technique. The sensor consisted of a capture anti-OTC antibody (anti-OTC) and OTC-conjugated bovine serum albumin (OTC-BSA). Anti-OTC was first anchored onto the functionalized PAD, followed by the competitive binding of the OTC target and OTC-BSA. The amount of the captured OTC was examined by observing the signal response of the redox [Fe(CN)(6)]3(-)/4(-). In the presence of OTC, the current response was significantly increased with increasing OTC concentration, whereas the signal response was negligible in the absence thereof. The detected OTC concentration was linear over a range of 1-200 ng mL(-1), and the corresponding values of 0.33 and 1.1 ng mL(-1) were obtained for the limit of detection (LOD) and limit of quantitation (LOQ), respectively. This introduced sensor displayed high sensitivity and specificity, and the amounts of OTC were successfully quantified in agricultural products. This developed signal-on sensor may be an alternative tool for determining OTC residues and broader antibiotic targets.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Proximity-based electrochemical biosensor for highly sensitive determination of methyltransferase activity using gold nanoparticle-based cooperative signal amplification
    Zhang Zhang
    Shangchun Sheng
    Xianqing Cao
    Yiyan Li
    Juan Yao
    Ting Wang
    Guoming Xie
    [J]. Microchimica Acta, 2015, 182 : 2329 - 2336
  • [42] Competitive Chemiluminescent Immunoassay for the Sensitive Point-of-Care Determination of Metoprolol
    Zhang, Lisha
    Long, Hao
    Song, Pei
    Li, Xiaogang
    Xu, Kun
    Meng, Meng
    Yin, Yongmei
    Xi, Rimo
    [J]. ANALYTICAL LETTERS, 2017, 50 (03) : 470 - 481
  • [43] A sensitive electrochemical biosensor for quinolones detection based on Cu2+-modulated signal amplification
    Yan, Yuting
    Zhou, Fangfang
    Wang, Qian
    Huang, Yue
    [J]. MICROCHEMICAL JOURNAL, 2023, 190
  • [44] Peptide-conjugated hemin/G-quadruplex as a versatile probe for "signal-on" electrochemical peptide biosensor
    Ye, Zhuo
    Li, Gaiping
    Xu, Lingling
    Yu, Qian
    Yue, Xiaoyue
    Wu, Yongmei
    Ye, Baoxian
    [J]. TALANTA, 2020, 209
  • [45] Highly Sensitive Electrochemical Immunoassay Using Signal Amplification of the Coagulation Cascade
    Ito, Kentaro
    Inoue, Kumi Y.
    Ino, Kosuke
    Shiku, Hitoshi
    [J]. ANALYTICAL CHEMISTRY, 2022, 94 (36) : 12427 - 12434
  • [46] A universal electrochemical biosensor for the highly sensitive determination of microRNAs based on isothermal target recycling amplification and a DNA signal transducer triggered reaction
    Lili Zhou
    Jian Wang
    Zhongping Chen
    Junlong Li
    Ting Wang
    Zhang Zhang
    Guoming Xie
    [J]. Microchimica Acta, 2017, 184 : 1305 - 1313
  • [47] A universal electrochemical biosensor for the highly sensitive determination of microRNAs based on isothermal target recycling amplification and a DNA signal transducer triggered reaction
    Zhou, Lili
    Wang, Jian
    Chen, Zhongping
    Li, Junlong
    Wang, Ting
    Zhang, Zhang
    Xie, Guoming
    [J]. MICROCHIMICA ACTA, 2017, 184 (05) : 1305 - 1313
  • [48] A signal-on electrochemiluminescence aptamer biosensor for the detection of ultratrace thrombin based on junction-probe
    Zhang, Jing
    Chen, Pingping
    Wu, XiaoYan
    Chen, JingHua
    Xu, LiangJun
    Chen, GuoNan
    Fu, FengFu
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2645 - 2650
  • [49] A signal-on magnetic electrochemical immunosensor for ultra-sensitive detection of saxitoxin using palladium-doped graphitic carbon nitride-based non-competitive strategy
    Jin, Xin
    Chen, Jianlang
    Zeng, Xiaoxue
    Xu, LiangJun
    Wu, Yongning
    Fu, FengFu
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 128 : 45 - 51
  • [50] Signal-On Fluorescence Biosensor for Highly Sensitive Detection of miRNA-21 Based on DNAzyme Assisted Double-Hairpin Molecular Beacon
    Fang, Chenxin
    Yang, Yuxing
    Zou, Shuhao
    Ouyang, Ping
    Qing, Yang
    Han, Jialun
    Li, Haiyu
    Wang, Zhencui
    Du, Jie
    [J]. BIOSENSORS-BASEL, 2022, 12 (05):