Subzero-temperature liquid-liquid extraction of benzodiazepines for high performance liquid chromatography

被引:55
|
作者
Yoshida, M [1 ]
Akane, A [1 ]
机构
[1] Kansai Med Univ, Dept Legal Med, Moriguchi, Osaka 5708506, Japan
关键词
D O I
10.1021/ac981276g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On the basis of the phenomenon that hydrophilic acetonitrile is separated from the aqueous phase at -20 degrees C, we employed a novel extraction method, "subzero-temperature liquid-liquid extraction", to extract benzodiazepines (estazolam and triazolam) from serum or aqueous solution for liquid chromatography. A 1:1 mixture of acetonitrile and the specimen was cooled at -20 degrees C for 20 min to separate the acetonitrile and aqueous phases. The acetonitrile phase was directly injected into a highperformance liquid chromatograph. Recovery rates of the drugs following the first subzero-temperature liquid-liquid extraction were 50.3 +/- 0.6 - 54.0 +/- 0.9%, which were lower than those (73.9 +/- 3.3 - 80.6 +/- 0.6% and 81.6 +/- 4.7 - 96.1 +/- 2.6%) of the first conventional liquid-liquid extraction using diethyl ether and solid-phase extraction using a Sep-Pak C18 column, respectively. However, three to four repeated subzero-temperature liquid-liquid extractions and conventional liquid-liquid extractions resulted in recovery of almost 100% of the drugs. In the chromatogram of the benzodiazepines recovered from serum by the subzero-temperature extraction, no coextracted component interfered with determination of the drugs. Detection limits of the drugs were 0.02 - 0.08 mu g/mL, land coefficients of variance were 1.14 - 2.17% suggesting high reproducibility.
引用
收藏
页码:1918 / 1921
页数:4
相关论文
共 50 条
  • [41] Determination of Biogenic Amines in Wine Using Modified Liquid-Liquid Extraction with High Performance Liquid Chromatography-Fluorescence Detector
    Liu, Yang
    Han, Fuliang
    Liu, Yangjie
    Wang, Wanni
    FOOD ANALYTICAL METHODS, 2020, 13 (04) : 911 - 922
  • [42] Sensitive determination of docetaxel in human plasma by liquid-liquid extraction and reversed-phase high-performance liquid chromatography
    Loos, WJ
    Verweij, J
    Nooter, K
    Stoter, G
    Sparreboom, A
    JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (02): : 437 - 441
  • [43] Determination of Biogenic Amines in Wine Using Modified Liquid-Liquid Extraction with High Performance Liquid Chromatography-Fluorescence Detector
    Yang Liu
    Fuliang Han
    Yangjie Liu
    Wanni Wang
    Food Analytical Methods, 2020, 13 : 911 - 922
  • [44] Sensitive determination of nitrophenol isomers by reverse-phase high-performance liquid chromatography in conjunction with liquid-liquid extraction
    Boddu, Veera
    Kim, Sanghoon
    Adkins, Jason
    Weimer, Ellyn
    Paul, Tias
    Damavarapu, Reddy
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (11) : 1053 - 1064
  • [45] CHROMATOGRAPHY BY LIQUID-LIQUID PARTITION AND LIQUID-LIQUID INTERFACE ADSORPTION
    VANDUIN, H
    NATURE, 1957, 180 (4600) : 1473 - 1473
  • [46] Determination of neonicotinoid insecticide residues in edible oils by water-induced homogeneous liquid-liquid extraction and dispersive liquid-liquid extraction followed by high performance liquid chromatography-diode array detection
    Farajzadeh, Mir Ali
    Mogaddam, Mohammad Reza Afshar
    Alizadeh, Ali Akbar
    RSC ADVANCES, 2015, 5 (95) : 77501 - 77507
  • [47] Extraction and determination of three benzodiazepines in aqueous and biological samples by air-assisted liquid–liquid microextraction and high-performance liquid chromatography
    Mehdi Ghadi
    Mohammad Reza Hadjmohammadi
    Journal of the Iranian Chemical Society, 2019, 16 : 1147 - 1155
  • [48] Determination of triazines in honey by dispersive liquid-liquid microextraction high-performance liquid chromatography
    Wang, Ying
    You, Jingyan
    Ren, Ruibing
    Xiao, Yao
    Gao, Shiqian
    Zhang, Hanqi
    Yu, Aimin
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (26) : 4241 - 4246
  • [49] Determination of Trace Bisphenol A in Water by High Performance Liquid Chromatography with Dispersive Liquid-liquid Microextraction
    Li Yu
    Liu Jian-Lin
    Wang Xiao-Li
    Jian Ying-Hong
    Dong De-Ming
    Li Na
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2008, 29 (11): : 2142 - 2148
  • [50] Determination of trace bisphenol A in water by high performance liquid chromatography with dispersive liquid-liquid microextraction
    Energy and Environment Research Centre, North China Electric Power University, Beijing 102206, China
    不详
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao, 2008, 11 (2142-2148): : 2142 - 2148