2D-finite element analyses and histomorphology of lag screws with and without a biconcave washer

被引:13
|
作者
Schuller-Götzburg, P
Krenkel, C
Reiter, TJ
Plenk, H
机构
[1] Univ Vienna, Inst Histol Embryol, Bone Biomat Res Lab, LKA Salzburg, Austria
[2] Dept Oral & Maxillofacial Surg, LKA Salzburg, Austria
[3] Vienna Univ Technol, Inst Lightweight Struct & Aerosp Engn, Vienna, Austria
关键词
lag screw osteosynthesis; 2D-FE-analyses; histomorphology;
D O I
10.1016/S0021-9290(98)00156-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
For osteosynthesis and for bone transplant fixation in particular, a lag screw with a biconcave washer, the so called "Anchor Screw" (AS) has been introduced in maxillo-facial surgery. Using 2D-finite element analysis (FEA), the v.Mises and the circumferential stresses induced in underlying bone by this AS are analysed and compared to those under a conventional lag screw. The stress distributions below the biconcave washer of the AS were correlated with histomorphological bone reactions after AS osteosynthesis in two tumor patients. retrieved 12 weeks and 19 months after tumor surgery, respectively. Depending on the thickness of cortical bone, the v.Mises stress concentrations below the biconcave washer were lower than under the head of the conventional lag screw (CLS), but with a higher stress maximum concentrated around the rim of the washer. The circumferential stresses were only half as high around the AS, and thus the deformation of bone was reduced. As predicted by FEA, histology showed microcrack formation, but then after minimal resorptionl remodelling of bone below the biconcave washer. Stable osteosynthesis could be demonstrated by bony union already after 12 weeks, and, while bone remodelling continued in the healed osteotomy, it had decreased around the screws after 19 months. It can be concluded from the biomechanical principles and the histomorphological findings that the AS appears superior to the CLS. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:511 / 520
页数:10
相关论文
共 50 条
  • [1] 2D-Finite Element Model of a CIGS Module
    Janssen, G. J. M.
    Slooff, L. H.
    Bende, E. E.
    2012 38TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2012, : 1481 - 1485
  • [2] 2D-finite element models of the TMJ in three different mandible positions, simulation of clenching
    Aoun, M.
    Mesnard, M.
    Ramos, A.
    Morlier, J.
    Puel, F.
    Cid, M.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 : 15 - 17
  • [3] The self adapting washer for lag screw fixation of mandibular fractures:: finite element analysis and preclinical evaluation
    Terheyden, H
    Mühlendyck, C
    Feldmann, H
    Ludwig, K
    Härle, F
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1999, 27 (01) : 58 - 67
  • [4] A Bridge between Finite Element and Shear Lag Analyses for Fiber Pull Out
    Avery, G.
    Riddell, W. T.
    PROCEEDINGS OF THE AMERICAN SOCIETY FOR COMPOSITES: THIRTIETH TECHNICAL CONFERENCE, 2015, : 1438 - 1450
  • [5] Increasing bending strength of tibial locking screws: Mechanical tests and finite element analyses
    Chao, Ching-Kong
    Hsu, Ching-Chi
    Wang, Jaw-Lin
    Lin, Jinn
    CLINICAL BIOMECHANICS, 2007, 22 (01) : 59 - 66
  • [6] 2D and 3D finite element analyses of overlapping tunnels
    Chen, Xian-Guo
    Wang, Xian-Jun
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2003, 38 (06):
  • [7] A unified finite element method for the simulation of hydraulic fracturing with and without fluid lag
    Bao, J. Q.
    Fathi, E.
    Ameri, S.
    ENGINEERING FRACTURE MECHANICS, 2016, 162 : 164 - 178
  • [8] High-speed predictions of post-burn contraction using a neural network trained on 2D-finite element simulations
    Egberts, Ginger
    Vermolen, Fred
    van Zuijlen, Paul
    FRONTIERS IN APPLIED MATHEMATICS AND STATISTICS, 2023, 9
  • [9] Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses
    Hsu, CC
    Chao, CK
    Wang, JL
    Hou, SM
    Tsai, YT
    Lin, J
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (04) : 788 - 794
  • [10] Increasing bending strength and pullout strength in conical pedicle screws: Biomechanical tests and finite element analyses
    Chao, Ching-Kong
    Hsu, Ching-Chi
    Wang, Jaw-Lin
    Lin, Jinn
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (02): : 130 - 138