Evaluation of Intracochlear Trauma Caused by Insertion of Cochlear Implant Electrode Arrays through Different Quadrants of the Round Window

被引:15
|
作者
Queiroz Martins, Graziela de Souza [1 ,2 ]
Brito Neto, Rubens Vuono [2 ]
Tsuji, Robinson Koji [2 ]
Mello Santiago Gebrim, Eloisa Maria [3 ]
Bento, Ricardo Ferreira [2 ]
机构
[1] Univ Sao Paulo, Fac Med, Dept Med, BR-05403000 Sao Paulo, SP, Brazil
[2] FMUSP, Clin Hosp, Dept Otorhinolaryngol, BR-05403000 Sao Paulo, SP, Brazil
[3] FMUSP, Clin Hosp, Dept Radiol, BR-05403000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
RESIDUAL HEARING; INNER-EAR; PRESERVATION; ANATOMY; COCHLEOSTOMY;
D O I
10.1155/2015/236364
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Hypothesis. This study aimed to evaluate whether there is a difference in the degree of intracochlear trauma when the cochlear implant electrode arrays is inserted through different quadrants of the round window membrane. Background. The benefits of residual hearing preservation in cochlear implant recipients have promoted the development of atraumatic surgeries. Minimal trauma during electrode insertion is crucial for residual hearing preservation. Methods. In total, 25 fresh human temporal bones were subjected to mastoidectomy and posterior tympanotomy. The cochlear implant electrode array was inserted through the anterosuperior quadrant of the round window membrane in 50% of the bones and through the anteroinferior quadrant in the remaining 50%. The temporal bones were dehydrated, embedded in epoxy, serially polished, stained, viewed through a stereomicroscope, and photographed with the electrode arrays in situ. The resulting images were analyzed for signs of intracochlear trauma. Results. Histological examinations revealed varying degrees of damage to the intracochlear structures, although the incidence and severity of intracochlear trauma were not influenced by the quadrant of insertion. Conclusions. The incidence and severity of intracochlear trauma were similar in all samples, irrespective of electrode array insertion through the anterosuperior or anteroinferior quadrant of the round window membrane.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Patterns Seen During Electrode Insertion Using Intracochlear Electrocochleography Obtained Directly Through a Cochlear Implant
    Harris, Michael S.
    Riggs, William J.
    Giardina, Christopher K.
    O'Connell, Brendan P.
    Holder, Jourdan T.
    Dwyer, Robert T.
    Koka, Kanthaiah
    Labadie, Robert F.
    Fitzpatrick, Douglas C.
    Adunka, Oliver F.
    OTOLOGY & NEUROTOLOGY, 2017, 38 (10) : 1415 - 1420
  • [22] The perceived angle of the round window affects electrode insertion trauma in round window insertion - an anatomical study
    Shapira, Yisgav
    Eshraghi, Adrien A.
    Balkany, Thomas J.
    ACTA OTO-LARYNGOLOGICA, 2011, 131 (03) : 284 - 289
  • [23] Landmarks for Proper Round Window Electrode Insertion in Cochlear Implantation
    El Fiky, Lobna
    Mostafa, Badr Eldin
    Ibrahim, Samer Ahmed
    Teaima, Ahmed Abdelmoneim
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2022, 18 (03): : 210 - 213
  • [24] Cochlear implantation outcomes with round window electrode insertion versus cochleostomy insertion
    Elafandi, Haytham
    Khalifa, Mohamed Adel
    Elguindy, Ahmed S.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2020, 138
  • [25] Imaging evaluation of electrode placement and effect on electrode discrimination on different cochlear implant electrode arrays
    Ramos de Miguel, Angel
    Argudo, Andrea A.
    Borkoski Barreiro, Silvia A.
    Falcon Gonzalez, Juan Carlos
    Ramos Macias, Angel
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2018, 275 (06) : 1385 - 1394
  • [26] Imaging evaluation of electrode placement and effect on electrode discrimination on different cochlear implant electrode arrays
    Ángel Ramos de Miguel
    Andrea A. Argudo
    Silvia A. Borkoski Barreiro
    Juan Carlos Falcón González
    Angel Ramos Macías
    European Archives of Oto-Rhino-Laryngology, 2018, 275 : 1385 - 1394
  • [27] Insertion trauma of a cochlear implant electrode array with Nitinol inlay
    Rau, Thomas S.
    Harbach, Lenka
    Pawsey, Nick
    Kluge, Marcel
    Erfurt, Peter
    Lenarz, Thomas
    Majdani, Omid
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (11) : 3573 - 3585
  • [28] Cochlear implant deep electrode insertion: Extent of insertional trauma
    Gstoettner, W
    Plenk, H
    Franz, P
    Hamzavi, J
    Baumgartner, W
    Czerny, C
    Ehrenberger, K
    ACTA OTO-LARYNGOLOGICA, 1997, 117 (02) : 274 - 277
  • [29] Insertion trauma of a cochlear implant electrode array with Nitinol inlay
    Thomas S. Rau
    Lenka Harbach
    Nick Pawsey
    Marcel Kluge
    Peter Erfurt
    Thomas Lenarz
    Omid Majdani
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 3573 - 3585
  • [30] PREOPERATIVE COCHLEAR IMPLANT ASSESSMENT USING A ROUND WINDOW BALL ELECTRODE
    RYAN, RM
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1989, : 11 - 13