Initial experience of occluding special type patent ductus arterioses using the Amplatzer vascular plug

被引:0
|
作者
Zhang Po [1 ]
Zhu Xian-yang [1 ]
Wang Qi-guang [1 ]
Zhang Duan-zhen [1 ]
Han Xiu-min [1 ]
机构
[1] Shenyang Mil Command, Peoples Liberat Army Gen Hosp, Cardiovasc Res Inst, Dept Congenital Heart Dis, Shenyang 110016, Liaoning, Peoples R China
关键词
patent ductus arteriosus; heart catheterization; intervention studies; therapeutic occlusion; Amplatzer vascular plug I; TRANSCATHETER CLOSURE; OCCLUSION; EMBOLIZATION;
D O I
10.3760/cma.j.issn.0366-6999.20123318
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Occluders licensed for clinical use are not fit for some special Krichenko E patent ductus arterioses. The Amplatzer vascular plug I (AVP1) has not been licensed for use for closure of patent ductus arteriose. We report our initial experience to occluding special type patent ductus arterioses with the AVP1 a single lobe device of single layer Nitinol mesh for short vessel landing zones. Methods Patients referred with small and long Krichenko E patent ductus arterioses 1 mm to 3 mm in diameter underwent occlusion using AVP1. All cases underwent pre-, intra- and post-procedural echocardiography and chest X-ray at the completion of the procedure, the next day and at a 30-day, 3-month and 6-month follow-up visits. Device sizing for device waist diameter and length was based on aortography. Results From April 2008 to June 2012, 26 patients with a mean age of (7.6 +/- 8.0) years (range 6 months-32 years) and a mean weight of (23.8 +/- 14.8) kg (range 7-67 kg) underwent successful patent ductus arteriose closure. The mean ductus diameter was (2.1 +/- 0.7) mm (range 1-3 mm). Transpulmonary (22/26) and transaortic approaches (4/26) were used. No persistent patency was observed after 24 hours and after one month. No device displacement, residual flow and iatrogenic coarctation of the aorta were observed after three months and six months. Conclusions The AVP1 makes it easy to close some Krichenko E patent ductus arterioses. Smaller delivery catheter profile and symmetric cylindrical device shape allow for use for small and long Krichenko E patent ductus arterioses 1 mm to 3 mm in diameter and small patients through transaortic approaches. Broader experience is required to further delineate device and patient selection as well as to document its long-term efficacy and safety.
引用
收藏
页码:3456 / 3459
页数:4
相关论文
共 50 条
  • [31] The use of Amplatzer vascular plug II in 32 consecutive dogs for transvenous occlusion of patent ductus arteriosus
    Belachsen, O.
    Sargent, J.
    Koffas, H.
    Schneider, M.
    Wagner, T.
    [J]. JOURNAL OF VETERINARY CARDIOLOGY, 2022, 41 : 88 - 98
  • [32] Transcatheter occlusion of patent ductus arteriosus using a new angled Amplatzer duct occluder: Initial clinical experience
    Masura, J
    Gavora, P
    Podnar, T
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) : 261 - 267
  • [33] Use of the Amplatzer Vascular Plug II Device to Occlude Different Types of Patent Ductus Arteriosus in Pediatric Patients
    Garay, Francisco J.
    Aguirre, Daniel
    Cardenas, Luis
    Springmuller, Daniel
    Heusser, Felipe
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2015, 28 (02) : 198 - 204
  • [34] The AMPLATZER Vascular Plug 4: Preliminary Experience
    Carlo Ferro
    Umberto G. Rossi
    Giulio Bovio
    Francesco Petrocelli
    Sara Seitun
    [J]. CardioVascular and Interventional Radiology, 2010, 33 : 844 - 848
  • [35] The AMPLATZER Vascular Plug 4: Preliminary Experience
    Ferro, Carlo
    Rossi, Umberto G.
    Bovio, Giulio
    Petrocelli, Francesco
    Seitun, Sara
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (04) : 844 - 848
  • [36] Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder
    Thanopoulos, BD
    Hakim, FA
    Hiari, A
    Goussous, Y
    Basta, E
    Zarayelyan, AA
    Tsaousis, GS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (04) : 1016 - 1021
  • [37] Neuroapplication of Amplatzer Vascular Plug for Therapeutic Sacrifice of Major Craniocerebral Arteries: An Initial Clinical Experience
    Ong, Cheng Kang
    Lam, Dang V.
    Ong, Michelle T.
    Power, Mark A.
    Parkinson, Richard J.
    Wenderoth, Jason D.
    [J]. ANNALS ACADEMY OF MEDICINE SINGAPORE, 2009, 38 (09) : 763 - 768
  • [38] Acute Aortic Dissection as a Rare Complication of Percutaneous Closure Using the Amplatzer Vascular Plug II for a Tubular and Enlarged Patent Ductus Arteriosus in an Elderly Patient
    Yamamoto, Hiroyuki
    Otake, Hiromasa
    Akagi, Teiji
    Matsumoto, Kensuke
    Henmi, Soichiro
    Inoue, Takeshi
    Tanaka, Hiroshi
    Hirata, Ken-ichi
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (01) : E5 - E7
  • [39] Transcatheter closure of patent ductus arteriosus using occluding spring coils
    Stokhof, AA
    Sreeram, N
    Wolvekamp, WTC
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2000, 14 (04) : 452 - 455
  • [40] Transcatheter closure with a "single lobe" Amplatzer Vascular Plug of a tubular patent ductus arteriosus in a neonate with transposition of the great arteries and heart failure
    Sharma, Shiv-Raj
    Michielon, Guido
    Fraisse, Alain
    [J]. CARDIOLOGY IN THE YOUNG, 2023, 33 (08) : 1453 - 1455