Simultaneous measurement of refractive index and thickness of multilayer systems using Fourier domain optical coherence tomography, part 1: theory

被引:4
|
作者
Rajai, Payman [1 ]
Schriemer, Henry [1 ,2 ]
Amjadi, Ahmad [3 ]
Munger, Rejean [1 ]
机构
[1] Univ Ottawa, Dept Phys, 150 Louis Pasteur, Ottawa, ON K1N 6N5, Canada
[2] Univ Ottawa, Sch Elect Engn & Comp Sci, Ottawa, ON K1N 6N5, Canada
[3] Sharif Univ Technol, Dept Phys, POB 11155-9161, Tehran, Iran
关键词
optical coherence tomography; Fourier domain; refractive index; multilayer systems; TRANSPARENT PLATES; MULTIPLE LAYERS; INTERFEROMETRY; TISSUE; SEGMENTATION; DISPERSION;
D O I
10.1117/1.JBO.22.1.015002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We introduce a theoretical framework for simultaneous refractive index and thickness measurement of multilayer systems using the Fourier domain optical coherence tomography (FD-OCT) system without any previous information about the item under investigation. The input data to the new formalism are the FD-OCT measured optical path lengths and properly selected spectral components of the FD-OCT interference spectrum. No additional arrangement, reference reflector, or mechanical scanning is needed in this approach. Simulation results show that the accuracy of the extracted parameters depends on the index contrast of the sample while it is insensitive to the sample's thickness profile. For transparent biological samples with smooth interfaces, when the object is in an aqueous medium and has indices <1.55, this method can extract indices and thicknesses with the absolute error <= 0.001. (C) 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Simultaneous measurement of refractive index and thickness of multilayer systems using Fourier domain optical coherence tomography, part 2: implementation
    Rajai, Payman
    Schriemer, Henry
    Amjadi, Ahmad
    Munger, Rejean
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (01)
  • [2] Simultaneous analysis of refractive index and physical thickness by Fourier domain optical coherence tomography
    Tomlins, P. H.
    Wang, R. K.
    [J]. IEE PROCEEDINGS-OPTOELECTRONICS, 2006, 153 (05): : 222 - 228
  • [3] Developing a New Dimension for Fourier Domain Optical Coherence Tomography Images by Simultaneous Measurement of the Refractive Index and Thickness
    Amjadi, Ahmad
    Ghodsi, Hamed
    Khandani, Salile
    Khishkhah, Bahareh
    Rajai, Payman
    Razzaghi, Mohammadreza
    [J]. JOURNAL OF LASERS IN MEDICAL SCIENCES, 2021, 12
  • [4] Simultaneous measurement of group refractive index and thickness of optical samples using optical coherence tomography
    Cheng, Hsu-Chih
    Liu, Yi-Cheng
    [J]. APPLIED OPTICS, 2010, 49 (05) : 790 - 797
  • [5] Layer dependent refractive index measurement by Fourier domain optical coherence tomography
    Tomlins, Peter H.
    Wang, Ruikang K.
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [6] Simultaneous refractive index and thickness measurements of bio tissue by optical coherence tomography
    Wang, XY
    Zhang, CP
    Zhang, LS
    Xue, LL
    Tian, JG
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (04) : 628 - 632
  • [7] The measurements of refractive index and physical thickness using optical coherence tomography
    Song, GJ
    Wang, XZ
    Ren, HW
    Zhang, WZ
    Zhang, LY
    Fang, ZJ
    [J]. INTERNATIONAL CONFERENCE ON SENSORS AND CONTROL TECHNIQUES (ICSC 2000), 2000, 4077 : 171 - 174
  • [8] Matrix approach to quantitative refractive index analysis by Fourier domain optical coherence tomography
    Tomlins, Peter H.
    Wang, Ruikang K.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2006, 23 (08) : 1897 - 1907
  • [9] Simultaneous measurements of the thickness and refractive index of microstructures in obscure specimen by optical coherence tomography
    Song, GJ
    Wang, XZ
    Ren, HW
    Zhang, WZ
    Zhang, LY
    Fang, ZJ
    [J]. OPTIK, 2000, 111 (12): : 541 - 543
  • [10] Effects of Refractive Power on Macular Thickness Measurement Using Spectral-Domain Optical Coherence Tomography
    Lee, Sung Bok
    Shin, Il Hwan
    Shin, Kyung Sup
    Jo, Young Joon
    Kim, Jung Yeul
    [J]. OPHTHALMOLOGICA, 2015, 234 (03) : 172 - 176