MR imaging of the fetus by a in HASTE sequence

被引:158
|
作者
Yamashita, Y [1 ]
Namimoto, T [1 ]
Abe, Y [1 ]
Takahashi, M [1 ]
Iwamasa, J [1 ]
Miyazaki, K [1 ]
Okamura, H [1 ]
机构
[1] KUMAMOTO UNIV,SCH MED,DEPT OBSTET & GYNECOL,KUMAMOTO 860,JAPAN
关键词
D O I
10.2214/ajr.168.2.9016238
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The value of a half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence, in which high-resolution heavily T2-weighted images can be obtained within 2 sec, was evaluated in the imaging of the fetus during the second or third trimester. MATERIALS AND METHODS. Eighteen women with complicated pregnancies as revealed on a sonogram during the second and third trimesters (16-36 weeks' gestation) were studied with a 1.5-T superconductive MR imaging unit that used a body phased-array coil. After informed consent, T1-weighted fast low-angle shot images, T2-weighted turbo spin-echo images, and HASTE images were obtained without any premedication. Images were analyzed with regard to image quality, degree of blurring, visualization of the normal fetal organs, and visualization of fetal and maternal abnormalities. RESULTS. On HASTE sequences, visualization of the fetal brain, Visceral organs (lung, heart, liver, kidney, and bladder), extremities, and umbilical cord were significantly better than on fast low-angle shot or turbo spin-echo sequences (p < .01). In the brain, the white matter-gray matter distinction, gyrus formation, and myelination of the brain were clearly revealed by the HASTE sequence. Pathologic processes including fetal abnormalities (anomalies of the central nervous systems [n = 5], placenta previa [n = 2], ascites [n = 1], and transverse lie in the third trimester [n = 1]) and maternal abnormalities (leiomyoma [n = 5], ovarian tumors [n = 3], and hydronephrosis [n = 1]) were clearly seen on HASTE imaging. The peak specific absorption rate for RF exposure in these studies was less than 1.5 W/kg. CONCLUSION. In situations when sonography is suggestive but not definitive, MR imaging with a HASTE sequence allows clear fetal imaging with high T2-weighted contrast.
引用
收藏
页码:513 / 519
页数:7
相关论文
共 50 条
  • [41] Cerebral perfusion MR imaging using FAIR-HASTE in chronic carotid occlusive disease: Comparison with dynamic susceptibility contrast-perfusion MR imaging
    Ida, Kentaro
    Akaki, Shiro
    Sei, Tetsuro
    Tsunoda, Masatoshi
    Kanazawa, Susumu
    ACTA MEDICA OKAYAMA, 2006, 60 (04) : 215 - 221
  • [42] MRI of bowel obstruction using the HASTE sequence
    Beall, DP
    Regan, F
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) : 823 - 825
  • [43] Fast MR imaging of focal hepatic lesions: Comparison of breath-hold turbo SE, breath-hold HASTE, and breath-hold HASTE STIR versus conventional T2-weighted SE sequence
    Lee, M
    Jeong, YK
    Han, D
    Seo, DJ
    Auh, YH
    Chien, D
    RADIOLOGY, 1996, 201 : 435 - 435
  • [44] Targeted-HASTE imaging with automated device tracking for MR-guided needle interventions in closed-bore MR systems
    Zimmermann, H.
    Mueller, S.
    Gutmann, B.
    Bardenheuer, H.
    Melzer, A.
    Umathum, R.
    Nitz, W.
    Semmler, W.
    Bock, M.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (03) : 481 - 488
  • [45] Value of HASTE MR urography in urinary tract disorders
    Tang, Y
    Yamashita, Y
    Namimoto, T
    Abe, Y
    Nishiharu, T
    Takahashi, M
    RADIOLOGY, 1996, 201 : 210 - 210
  • [46] Imaging with octreoscan: Haste makes waste
    van Uden, A
    Steinmeijer, MVJ
    de Swart, J
    Vink, M
    Kwekkeboom, DJ
    Valkema, R
    Krenning, EP
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1022 - 1022
  • [47] Quantitative MR Imaging: Physical Principles and Sequence Design in Abdominal Imaging
    Shah, Bhavya
    Anderson, Stephan W.
    Scalera, Jonathan
    Jara, Hernan
    Soto, Jorge A.
    RADIOGRAPHICS, 2011, 31 (03) : 867 - 880
  • [48] CLINICAL USE OF A NEW MR IMAGING PULSE SEQUENCE FOR BREAST IMAGING
    HARMS, SE
    HESLEY, KL
    FLAMIG, DP
    EVANS, WP
    CHEEK, JH
    PETERS, GN
    RADIOLOGY, 1992, 185 : 245 - 245
  • [49] BOLD fMRI using a modified HASTE sequence
    Ye, Yongquan
    Zhuo, Yan
    Xue, Rong
    Zhou, Xiaohong Joe
    NEUROIMAGE, 2010, 49 (01) : 457 - 466
  • [50] MR Imaging of the Extracranial Facial Nerve with the CISS Sequence
    Guenette, J. P.
    Ben-Shlomo, N.
    Jayender, J.
    Seethamraju, R. T.
    Kimbrell, V
    Tran, N-A
    Huang, R. Y.
    Kim, C. J.
    Kass, J., I
    Corrales, C. E.
    Lee, T. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (11) : 1954 - 1959