Short-Acting Gas Tamponade with Strict Face-Down Posturing for the Treatment of Idiopathic Macular Hole

被引:3
|
作者
Gotzaridis, Stratos [1 ]
Liazos, Efstathios [1 ]
Petrou, Petros [2 ]
Georgalas, Ilias [2 ]
机构
[1] Athens Retina Inst, Athens, Greece
[2] G Genimatas Univ Hosp, Dept Ophthalmol 1, Athens, Greece
关键词
Internal limited membrane; intravitreal gas tamponade; macular hole; pars plana vitrectomy; short-acting gas; INTERNAL-LIMITING MEMBRANE; OPTICAL COHERENCE TOMOGRAPHY; RANDOMIZED CLINICAL-TRIAL; INDOCYANINE GREEN; SULFUR-HEXAFLUORIDE; SURGERY; VITRECTOMY; OUTCOMES; REPAIR;
D O I
10.3109/08820538.2015.1132333
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: A retrospective consecutive case series to evaluate the safety and efficacy of 25 gauge pars plana vitrectomy, ILM peeling, 20% SF6 gas tamponade and strict posturing for the treatment of idiopathic full-thickness macular holes. Methods: We report the results of 106 consecutive eyes that underwent standard 25-gauge pars plana vitrectomy, brilliant peel-assisted internal limiting membrane peel, fluid: gas exchange with 20% SF6 and strict posturing for one week. All patients were followed up at one week, one month, three months, and nine months postoperatively. Biomicroscopy at day 1 and biomicroscopy and OCT at week 1, months 1, 3, and 9 were used to assess macular hole status postoperatively. Pre- and postoperative logMAR visual acuity was compared. Results: The macular hole was closed in 102/106 eyes postoperatively (96.2%). Four eyes showed unclosed macular holes and underwent additional SF6 intravitreal injection and strict posturing for 10 days. All macular holes were eventually closed without the need of a second surgical procedure. Mean visual acuity improved from 0.63 logMAR preoperatively to 0.39 logMAR postoperatively. One case of retinal toxicity was reported due to accidental intravitreal injection of antibiotic. Conclusions: 25-gauge vitrectomy, ILM peel, and short-acting gas tamponade are highly effective for the treatment of macular holes. Additional intravitreal gas injection followed by strict posturing seems to be a simple and effective treatment for unclosed holes.
引用
收藏
页码:597 / 601
页数:5
相关论文
共 50 条
  • [21] Significance of face-down positioning after macular hole surgery with long-acting gas - consecutive case control study
    Szurman, P
    Di Tizio, FM
    Lafaut, B
    Aisenbrey, S
    Grisanti, S
    Roters, S
    Bartz-Schmidt, KU
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2000, 217 (06) : 351 - 355
  • [22] Macular hole surgery with air tamponade and optical coherence tomography-based duration of face-down positioning
    Eckardt, Claus
    Eckert, Tillmann
    Eckardt, Ute
    Porkert, Ute
    Gesser, Caroline
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (08): : 1087 - 1096
  • [23] Surgical results regarding the correction of macular hole with and without face-down posturing using 25% SF6 gas: a retrospective case series
    Carvalho de Moura Bastos, Andre Luis
    de Avila, Marcos Pereira
    Cruvinel Isaac, David Leonardo
    Aguiar, Levy Paz
    Aguiar, Aline Guerreiro
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2020, 83 (05) : 361 - 365
  • [24] Long-term outcome of idiopathic macular hole vitrectomy without postoperative face-down positioning
    Yagi, Fumihiko
    Takumi, Tetsuro
    Tomita, Goji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [25] Comparison of face-down and seated position after idiopathic macular hole surgery: A randomized clinical trial
    Guillaubey, Alexandre
    Malvitte, Laure
    Lafontaine, Pierre Olivier
    Jay, Nicolas
    Hubert, Isabelle
    Bron, Alain
    Berrod, Jean Paul
    Creuzot-Garcher, Catherine
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (01) : 128 - 134
  • [26] Macular hole surgery without face-down positioning - A pilot study
    Tornambe, PE
    Poliner, LS
    Grote, K
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1997, 17 (03): : 179 - 185
  • [27] NO FACE-DOWN POSITIONING SURGERY FOR THE REPAIR OF CHRONIC IDIOPATHIC MACULAR HOLES
    Elborgy, Ebrahim S.
    Starr, Matthew R.
    Kotowski, Jacek G.
    Abou Chehade, Jackson E.
    Iezzi, Raymond
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (02): : 282 - 289
  • [28] Treatment of idiopathic macular hole with silicone oil tamponade
    Ivanovska-Adjievska, Biljana
    Boskurt, Salih
    Semiz, Faruk
    Yuzer, Hakan
    Dimovska-Jordanova, Vesna
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 1449 - 1454
  • [29] A COMPARISON OF STRICT FACE-DOWN POSITIONING WITH ADJUSTABLE POSITIONING AFTER PARS PLANA VITRECTOMY AND GAS TAMPONADE FOR RHEGMATOGENOUS RETINAL DETACHMENT
    Chen, Xiao
    Yan, Ying
    Hong, Ling
    Zhu, Li
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (05): : 892 - 898
  • [30] Intraocular pressure change with face-down positioning after macular hole surgery
    Choi, Sung Won
    Lee, Chong Eun
    Kim, Yu Cheol
    PLOS ONE, 2020, 15 (11):