摘要
It is generally acknowledged that harmonic distortion levels on distribution networks are steadily increasing due to the proliferation of non-linear loads. While customer complaints relating to harmonic distortion levels are relatively uncommon, and measured levels are typically well within the limits specified by national regulations and international standards, the increasing trend may mean that more active management by utilities will soon be required. Effective management of harmonic distortion levels will require knowledge not only of the level of disturbance, but also of how the disturbance levels vary with time, location, and the connected load. Accepted methods for assessing harmonic levels that rely on cumulative probability statistics are inadequate for this level of insight. In this paper voltage total harmonic distortion levels (THDv) from a distribution network power quality survey are analysed in terms of variation with time, system load and the physical characteristics of the monitored sites.
引用
收藏
页码:128 / +
页数:3
相关论文
共 50 条
  • [31] Analysis of Harmonic Characteristics in Distribution Network with Distributed PV
    Liao, Senlin
    Tian, Ye
    Gu, Taiyu
    Wang, Zhe
    Shang, Lei
    Liu, Fei
    2024 IEEE 19TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, ICIEA 2024, 2024,
  • [32] Analysis of Elevated Neutral-to-Earth Voltage in Distribution Systems With Harmonic Distortion
    Collins, Edward R.
    Jiang, Jian
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) : 1696 - 1702
  • [33] Analysis and Effect of Switching Frequency and Voltage Levels on Total Harmonic Distortion in Multilevel Inverters
    Rao, A. Purna Chandra
    Obulesh, Y. P.
    Babu, Ch. Sai
    2012 INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ELECTRICAL ENGINEERING AND ENERGY MANAGEMENT (ICETEEEM - 2012), 2012,
  • [34] Total harmonic distortion analysis simulation
    Abbas, MH
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 1631 - 1634
  • [35] Analysis of harmonic distortion in the colpitts oscillator
    Palumbo, Gaetano
    Pennisi, Melita
    Pennisi, Salvatore
    2006 13TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-3, 2006, : 196 - 199
  • [36] Operator o and analysis of harmonic distortion
    Borys, Andrzej
    INTERNATIONAL JOURNAL OF ELECTRONICS AND TELECOMMUNICATIONS, 2016, 62 (03) : 261 - 265
  • [37] ANALYSIS OF HARMONIC DISTORTION IN ELECTROACOUSTIC TRANSDUCERS
    SHERMAN, CH
    BUTLER, JL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (03): : 1596 - 1611
  • [38] A FAULT-INDUCED TRANSIENT ANALYSIS OF UNBALANCED DISTRIBUTION-SYSTEMS WITH HARMONIC DISTORTION
    MAKRAM, EB
    GIRGIS, AA
    ELECTRIC POWER SYSTEMS RESEARCH, 1989, 17 (02) : 89 - 99
  • [39] POWER QUALITY AND HARMONIC DISTORTION ON DISTRIBUTION-SYSTEMS
    PHIPPS, JK
    NELSON, JP
    SEN, PK
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (02) : 476 - 484
  • [40] Indices for Harmonic Distortion Monitoring of Power Distribution Systems
    Vlahinic, Sasa
    Brnobic, Dalibor
    Stojkovic, Nino
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 421 - 425