Analysis of harmonic distortion levels on a distribution network

被引:0
|
作者
Nicholson, Glenn [1 ]
Gosbell, V. J. [2 ]
Parsotam, Ashok [3 ]
机构
[1] Manukau Inst Technol, Dept Elect & Comp Engn, Auckland, New Zealand
[2] Univ Wollongong, Integral Energy Power Qual & Reliabil Ctr, Wollongong, NSW 2522, Australia
[3] Vector NZ Ltd, Tauranga, New Zealand
关键词
harmonic distortion; power quality;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
It is generally acknowledged that harmonic distortion levels on distribution networks are steadily increasing due to the proliferation of non-linear loads. While customer complaints relating to harmonic distortion levels are relatively uncommon, and measured levels are typically well within the limits specified by national regulations and international standards, the increasing trend may mean that more active management by utilities will soon be required. Effective management of harmonic distortion levels will require knowledge not only of the level of disturbance, but also of how the disturbance levels vary with time, location, and the connected load. Accepted methods for assessing harmonic levels that rely on cumulative probability statistics are inadequate for this level of insight. In this paper voltage total harmonic distortion levels (THDv) from a distribution network power quality survey are analysed in terms of variation with time, system load and the physical characteristics of the monitored sites.
引用
收藏
页码:128 / +
页数:3
相关论文
共 50 条
  • [1] Synthesis of harmonic distortion levels in an LV distribution network
    Dyśko, A.
    Burt, G.M.
    McDonald, J.R.
    Clark, J.
    IEEE Power Engineering Review, 2001, 21 (05): : 58 - 60
  • [2] Third harmonic voltage distortion levels in an urban distribution network in El Salvador
    Ramos, Jose
    Pocasangre, Carlos
    Chevez, Luis
    Martinez, Armando
    Osorto, Josue
    Escobar, Diego
    PROCEEDINGS OF THE 2022 IEEE 40TH CENTRAL AMERICA AND PANAMA CONVENTION (CONCAPAN), 2022,
  • [3] PROCEDURE FOR DETERMINATION OF HARMONIC DISTORTION ALONG THE DISTRIBUTION NETWORK
    Stojkov, Marinko
    Trupinic, Kruno
    Nikolovski, Srete
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2009, 16 (04): : 19 - 26
  • [4] Unbalance and harmonic distortion assessment in an experimental distribution network
    Martin, Aranzazu D.
    Herrera, Reyes S.
    Vazquez, Jesus R.
    Crolla, Paul
    Burt, Graeme M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 127 : 271 - 279
  • [5] A new method for evaluation of harmonic distortion in reconfiguration of distribution network
    Amini, MohamadAli
    Jalilian, Alireza
    Behbahani, Milad Rahimi Pour
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (06)
  • [6] Distribution Network Capacity Assessment: Incorporating Harmonic Distortion Limits
    Sun, Wei
    Harrison, Gareth P.
    Djokic, Sasa Z.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [7] Analysis and Evaluating the Effect of Harmonic Distortion Levels in Industry
    Riaz, Muhammad Tanveer
    Afzal, Muhammad Muneeb
    Aaqib, Sheikh Muhammad
    Ali, Haider
    2021 4TH INTERNATIONAL CONFERENCE ON ENERGY CONSERVATION AND EFFICIENCY (ICECE 2021), 2021, : 52 - 58
  • [8] Measurement and analysis of harmonic distortion in power distribution systems
    Vlahinic, Sasa
    Brnobic, Dalibor
    Vucetic, Dubravko
    ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (07) : 1121 - 1126
  • [9] A method for a sensitivity analysis of the distribution system to harmonic distortion
    Bachry, A
    Styczynski, ZA
    10TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, VOLS I AND II, PROCEEDINGS, 2002, : 149 - 154
  • [10] Impact of EV Chargers on Total Harmonic Distortion in the Distribution System Network
    Bosak, Andrii
    Bosak, Alla
    Kulakovskyi, Leonid
    Oboronov, Taras
    2019 IEEE 6TH INTERNATIONAL CONFERENCE ON ENERGY SMART SYSTEMS (2019 IEEE ESS), 2019, : 329 - 333