Parameter Screening of PVDF/PVP Multi-Channel Capillary Membranes

被引:8
|
作者
Back, Jan O. [1 ]
Brandstaetter, Rupert [1 ]
Spruck, Martin [1 ]
Koch, Marc [1 ]
Penner, Simon [2 ]
Rupprich, Marco [1 ]
机构
[1] MCI Entrepreneurial Sch, Dept Environm Proc & Energy Engn, Maximilianstr 2, A-6020 Innsbruck, Austria
[2] Univ Innsbruck, Inst Phys Chem, Innrain 52c, A-6020 Innsbruck, Austria
关键词
multi-channel membrane; PVDF; PVP membrane; phase inversion process; design of experiments; HOLLOW-FIBER MEMBRANES; ULTRAFILTRATION MEMBRANES; EXPERIMENTAL-DESIGN; COAGULATION BATH; MOLECULAR-WEIGHT; SPINNING PROCESS; PHASE INVERSION; PORE-SIZE; MORPHOLOGY; PERFORMANCE;
D O I
10.3390/polym11030463
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The increasing research in the field of polymeric multi-channel membranes has shown that their mechanical stability is beneficial for a wide range of applications. The more complex interplay of formation process parameters compared to a single-channel geometry makes an investigation using Design of Experiments (DoE) appealing. In this study, seven-channel capillary membranes were fabricated in a steam-dry-wet spinning process, while varying the composition of the polymer solution and the process temperatures in a three-level fractional factorial linear screening design. The polymers polyvinylidene flouride (PVDF) was the chemically resistant main polymer and polyvinylpyrrolidone (PVP) was added as hydrophilic co-polymer. Scanning electron microscopy and atomic force microscopy were applied to study the membrane morphology. Fabrication process conditions were established to yield PVDF/PVP multi-channel membranes, which reached from high flux (permeability P = 321.4 L/m2/h/bar, dextran 500 kDa retention R = 18.3%) to high retention (P = 66.8 L/m2/h/bar, R = 80.0%). The concentration of the main polymer PVDF and the molecular weight of the co-polymer PVP showed linear relations with both P and R. The permeability could be increased using sodium hypochlorite post-treatment, although retention was slightly compromised. The obtained membranes may be suitable for micro- or ultra-filtration and, at the same time, demonstrate the merits and limitations of DoE for multi-channel membrane screening.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Joint routing and scheduling in multi-channel capillary machine-to-machine networks
    Kim, E.-J. (euijik.kim@kt.com), 1600, Springer International Publishing (2013):
  • [22] Multi-channel protocols
    Wong, Ford-Long
    Stajano, Frank
    SECURITY PROTOCOLS, 2007, 4631 : 112 - +
  • [23] Multi-channel protocols
    Wong, Ford-Long
    SECURITY PROTOCOLS, 2007, 4631 : 128 - 132
  • [24] Multi-channel attacks
    Agrawal, D
    Rao, JR
    Rohatgi, P
    CRYPTOGRAPHIC HARDWARE AND EMBEDDED SYSTEMS CHES 2003, PROCEEDINGS, 2003, 2779 : 2 - 16
  • [25] MULTI-CHANNEL SPECTROMETRY
    FELLGETT, PB
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1952, 42 (11) : 872 - 872
  • [26] Multi-channel cochlear
    Zhu, JM
    Zhu, LQ
    ISTM/2001: 4TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2001, : 1623 - 1624
  • [27] Treatment of oily waste water by PVP grafted PVDF ultrafiltration membranes
    Huang, Xin
    Wang, Weiping
    Liu, Yaodong
    Wang, Hui
    Zhang, Zhibing
    Fan, Wenling
    Li, Lei
    CHEMICAL ENGINEERING JOURNAL, 2015, 273 : 421 - 429
  • [28] SYPHILIS SCREENING USING MULTI-CHANNEL BLOOD-GROUPING MACHINE
    LOCKYER, JW
    BRITISH JOURNAL OF VENEREAL DISEASES, 1970, 46 (04): : 290 - &
  • [29] A multi-channel electrophoresis microchip platform for rapid chiral selector screening
    Gao, Yan
    Luo, Yong
    Qin, Jian-Hua
    Lin, Bing-Cheng
    PROCEEDINGS OF THE FIRST SHENYANG INTERNATIONAL COLLOQUIUM ON MICROFLUIDICS, 2007, : 264 - 265
  • [30] Preparation of PVDF-PVP Composite Membranes for Oily Wastewater Treatment
    Kartohardjono, Sutrasno
    Salsabila, Ghofira Muna Khansa
    Ramadhani, Azzahra
    Purnawan, Irfan
    Lau, Woei Jye
    MEMBRANES, 2023, 13 (06)