Analysis of serous body fluids using the CELL-DYN Sapphire hematology analyzer

被引:16
|
作者
Keuren, Jeffrey F. W. [1 ]
Hoffmann, Johannes J. M. L. [2 ]
Leers, Mathie P. G. [1 ]
机构
[1] Atrium Med Ctr, Dept Clin Chem & Hematol, NL-6401 CX Heerlen, Netherlands
[2] Abbott Diagnost Div, Wiesbaden, Germany
关键词
pleural effusion; mesothelial cells; microscopy;
D O I
10.1515/cclm-2012-0549
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Correct cell enumeration and differential analysis of body fluids are important in the diagnosis and management of several diseases. Currently, microscopic analysis is still considered the "gold standard". The aim of the present study was to evaluate the analytical performance of the CELL-DYN Sapphire hematology analyzer for automated differentiation of cells in serous fluids and to explore whether manual analysis of the raw data files could improve the differential count compared with reference microscopy. Methods: A total of 105 serous fluids (39 peritoneal and 66 pleural effusions) were analyzed by the CELL-DYN Sapphire using standard whole-blood algorithm. Additionally, we performed optimized manual gating of the Sapphire raw data file using standard flow cytometry software. Results: The standard Sapphire algorithm showed substantial deviations from the reference microscopic differentiation: polymorphonuclear cell counts were too high because they contained some monocytic cells. However, when optimized manual gating strategy is used, a good correlation and negligible bias were found. Conclusions: We have demonstrated that with a modified algorithm, CELL-DYN Sapphire will provide reliable identification and enumeration of blood cells in peritoneal and pleural fluids
引用
收藏
页码:1285 / 1290
页数:6
相关论文
共 50 条
  • [1] Use of the Cell-Dyn Sapphire Hematology Analyzer for Automated Counting of Blood Cells in Body Fluids
    De Smet, Dieter
    Van Moer, Guy
    Martens, Geert A.
    Nanos, Nikolaos
    Smet, Lutgarde
    Jochmans, Kristin
    De Waele, Marc
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2010, 133 (02) : 291 - 299
  • [2] Evaluation of the Abbott Cell-Dyn Sapphire hematology analyzer
    Park, Younhee
    Song, Jaewoo
    Song, Sungwook
    Song, Kyung Soon
    Ahn, Mee Suk
    Yang, Mi-Sook
    Kim, Il
    Choi, Jong Rak
    [J]. KOREAN JOURNAL OF LABORATORY MEDICINE, 2007, 27 (03): : 162 - 168
  • [3] Detection of imported malaria with the Cell-Dyn Sapphire ™ hematology analyzer
    Chesney, Alden
    Cardoso-Vouzoukos, Fatima
    Phillips, Ann-Marie
    Reis, Marciano
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2007, 29 : 49 - 49
  • [4] HEREDITARY SPHEROCYTOSIS SCREENING IN CHILDREN USING THE CELL-DYN SAPPHIRE HEMATOLOGY ANALYZER
    Rooney, Sean
    Cormack, Orla
    McMahon, Corrina
    Hoffmann, Johannes
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 : 123 - 123
  • [5] Immunophenotypic diagnosis of lymphoproliferative disorders using the Abbott CELL-DYN sapphire hematology analyzer.
    Settegrana, Catherine
    Maloum, Karim
    Souni, Fadila
    Septier, Isabelle
    Vinet, Sandrine
    Bonnemye, Patrick
    Merle-Beral, Helene
    [J]. BLOOD, 2006, 108 (11) : 183B - 183B
  • [6] Immunological screening for tumor cells in serous body fluids has added value with the CELL-DYN Sapphire
    Keuren, Jeffrey F. W.
    Hoffmann, Johannes J. M. L.
    Leers, Mathie P. G.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (02) : 253 - 258
  • [7] Evaluation of the Abbott CELL-DYN 4000 hematology analyzer
    Grimaldi, E
    Scopacasa, F
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2000, 113 (04) : 497 - 505
  • [8] EVALUATION OF THE CELL-DYN EMERALD 22 HEMATOLOGY ANALYZER
    Crespo, Santiago
    Antonio Royo, Jose
    Hoffmann, Johannes
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 30 - 30
  • [9] CELL-DYN SAPHIRE HEMATOLOGY ANALYZER AND SLIDES REVISION
    Molero, Teresa
    de la Iglesia, Silvia
    Lemes, Angelina
    Torres, Melissa
    Rodriguez, Carlos
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 : 55 - 55
  • [10] Detection of imported malaria with the Cell-Dyn 4000 hematology analyzer
    Wever, PC
    Henskens, YMC
    Kager, PA
    Dankert, J
    van Gool, T
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (12) : 4729 - 4731