Simultaneous intracranial EEG-fMRI in humans: Protocol considerations and data quality

被引:51
|
作者
Carmichael, D. W. [1 ,2 ]
Vulliemoz, S. [2 ,3 ,4 ]
Rodionov, R. [2 ]
Thornton, J. S. [5 ]
McEvoy, A. W. [6 ]
Lemieux, L. [2 ]
机构
[1] UCL Inst Child Hlth, Imaging & Biophys Unit, London WC1N 1EH, England
[2] UCL Inst Neurol, Dept Clin & Expt Epilepsy, London WC1E 6BT, England
[3] Univ Hosp, Dept Neurol, Epilepsy Unit, CH-1211 Geneva 14, Switzerland
[4] Univ Geneva, CH-1211 Geneva 14, Switzerland
[5] Natl Hosp Neurol & Neurosurg, Lysholm Dept Neuroradiol, London WC1N 3BG, England
[6] Natl Hosp Neurol & Neurosurg, Victor Horsley Dept Neurosurg, London WC1N 3BG, England
基金
瑞士国家科学基金会; 英国医学研究理事会;
关键词
EEG-fMRI; Intracranial EEG; Functional MRI; fMRI; Data quality; icEEG-fMRI; Electrophysiology; BOLD; Simultaneous EEG and fMRI; BOLD SENSITIVITY LOSSES; FUNCTIONAL MRI; ARTIFACT; SAFETY;
D O I
10.1016/j.neuroimage.2012.05.056
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We have recently performed simultaneous intracranial EEG and fMRI recordings (icEEG-fMRI) in patients with epilepsy. In this technical note, we examine limited thermometric data for potential electrode heating during our protocol and found that heating was <= 0.1 degrees C in-vitro at least 10 fold less than in-vivo limits. We quantify EEG quality, which can be degraded by MRI scanner-induced artefacts, and fMRI image (gradient echo echo-planar imaging: GE-EPI) signal quality around the electrodes, which can be degraded by electrode interactions with B1 (radiofrequency) and B0 (static) magnetic fields. We recorded EEG outside and within the MRI scanner with and without scanning. EEG quality was largely preserved during scanning and in particular heartbeat-related artefacts were small compared to epileptic events. To assess the GE-EPI signal reduction around the electrodes, we compared image signal intensity along paths into the brain normal to its surface originating from the individual platinum-iridium electrode contacts. GE-EPI images were obtained at 1.5 T with an echo time (TE) of 40 ms and repetition time (TR) of 3000 ms and a slice thickness of 2.5 mm. We found that GE-EPI signal intensity reduction was confined to a 10 mm radius and that it was reduced on average by less than 50% at 5 mm from the electrode contacts. The GE-EPI image signal reduction also varied with electrode orientation relative to the MRI scanner axes; in particular, cortical grid contacts with a normal along the scanner's main magnetic field (Be) axis have higher artefact levels relative to those with a normal perpendicular to the z-axis. This suggests that the artefacts were predominantly susceptibility-related rather than due to B1 interactions. This information can be used to guide interpretation of results of icEEG-fMRI experiments proximal to the electrodes, and to optimise artefact reduction strategies. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 50 条
  • [41] Preservation of EEG spectral power features during simultaneous EEG-fMRI
    Gallego-Rudolf, Jonathan
    Corsi-Cabrera, Maria
    Concha, Luis
    Ricardo-Garcell, Josefina
    Pasaye-Alcaraz, Erick
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [42] Causality within the epileptic network: an EEG-fMRI study validated by intracranial EEG
    Vaudano, Anna Elisabetta
    Avanzini, Pietro
    Tassi, Laura
    Ruggieri, Andrea
    Cantalupo, Gaetano
    Benuzzi, Francesca
    Nichelli, Paolo
    Lemieux, Louis
    Meletti, Stefano
    FRONTIERS IN NEUROLOGY, 2013, 4
  • [43] Sources of non-physiologic noise in simultaneous EEG-fMRI data: a phantom study
    Politte, David
    Prior, Fred
    Ponton, Curtis
    Nolan, Tracy
    Larson-Prior, Linda
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5129 - 5132
  • [44] A Novel Method To Map Interictal Epileptiform Discharges from Simultaneous EEG-fMRI Data
    Liu, Junjie
    Jobst, Barbara
    Darcey, Terrance
    Kobylarz, Erik
    NEUROLOGY, 2013, 80
  • [45] Correlated coupled matrix tensor factorization method for simultaneous EEG-fMRI data fusion
    Mosayebi, Raziyeh
    Hossein-Zadeh, Gholam-Ali
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 62
  • [46] Real-Time Filtering of Gradient Artifacts from Simultaneous EEG-fMRI Data
    Shaw, Saurabh Bhaskar
    2017 INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION IN NEUROIMAGING (PRNI), 2017,
  • [47] Design and Development of Simultaneous EEG-fMRI Data Acquisition Setup to Observe Brain Activity
    Ahmad, Rana Fayyaz
    Malik, Aamir Saeed
    Kamel, Nidal
    Reza, Faruque
    2014 IEEE INTERNATIONAL CONFERENCE ON CONTROL SYSTEM COMPUTING AND ENGINEERING, 2014, : 622 - 625
  • [48] SEMANTIC WORD-PICTURE-PRIMING IN SIMULTANEOUS EEG-FMRI
    Geukes, Sebastian
    Huster, Rene J.
    Wollbrink, Andreas
    Zwitserlood, Pienie
    Dobel, Christian
    PSYCHOPHYSIOLOGY, 2010, 47 : S25 - S25
  • [49] Reduction of the ballistocardiogram artifact in simultaneous EEG-fMRI using ICA
    Huiskamp, G. J. M.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3691 - 3694
  • [50] Simultaneous EEG-fMRI brain signatures of auditory cue utilization
    Scharinger, Mathias
    Herrmann, Bjoern
    Nierhaus, Till
    Obleser, Jonas
    FRONTIERS IN NEUROSCIENCE, 2014, 8