Non-Contact Axial Work piece Diameter Size Measuring System

被引:0
|
作者
Zheng, Hong [1 ]
Lu, Qi [1 ]
机构
[1] Univ Technol, Jinan 250353, Peoples R China
关键词
laser sensor; automatic scan; servo motor;
D O I
暂无
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
This article designs a non-contact axial work piece diameter size measuring system. It uses high accuracy laser sensor and precision linear module. This paper introduced working principle of the system, mechanical structure and measuring range. The characteristics include non-contact, high precision, automatic scanning and measuring range can be adjusted easily. The system is simple to adjust, easy to operate, especially suitable for plant operations or inspection as an important way of enterprise internal quality control. In addition, non-contact measurement is also significantly enhance the adaptability to environment and suitable for continuous measurement of work piece in production line.
引用
收藏
页码:909 / 912
页数:4
相关论文
共 50 条
  • [31] Diameter Measurement of Cylindrical Objects by Non-Contact Method
    Im, Bok Ryoung
    Kim, Sok Won
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2005, 16 (03) : 177 - 181
  • [32] DEVELOPMENTS IN ACCURATE NON-CONTACT MEASURING TECHNIQUES
    WALTON, H
    JOURNAL OF THE BRITISH NUCLEAR ENERGY SOCIETY, 1975, 14 (04): : 341 - 345
  • [33] Study of a non-contact position measuring method
    Wang, Zhi-Qian
    Xie, Mu-Jun
    Qiao, Yan-Feng
    Guangxue Jishu/Optical Technique, 2003, 29 (04): : 431 - 433
  • [34] Non-contact measuring - A comparison of position sensors
    Dorißen, Hans Theo
    Dürkopp, Klaus
    Irle, Henning
    AutoTechnology, 2005, 5 (APR.): : 68 - 71
  • [35] Non-contact transport system
    Morishita, M
    JOURNAL OF JAPANESE SOCIETY OF TRIBOLOGISTS, 1997, 42 (11) : 859 - 864
  • [36] INDUCTIVE NON-CONTACT METHOD FOR MEASURING A VELOCITY
    GAJEWSKI, JB
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (07): : 622 - 624
  • [37] Non-Contact Measuring of Manufacturing Technology.
    Pfeifer, Tilo
    Steger, Hans-Werner
    VDI-Z, 1986, 128 (17): : 629 - 634
  • [38] A mechanically non-contact axial flow blood pump
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 878 - 878
  • [39] Non-Contact Measurement of Blade Vibration in an Axial Compressor
    Przysowa, Radoslaw
    Russhard, Peter
    SENSORS, 2020, 20 (01)
  • [40] THE EFFECTIVENESS OF FISH LENGTH MEASUREMENT SYSTEM USING NON-CONTACT MEASURING APPROACH
    Jamaluddin, Muhammad Herman
    Seng, Chong Siong
    Shukor, Ahmad Zaki
    Ibrahim, Fariz Ali
    Miskon, Muhammad Fahmi
    Aras, Mohd Shahrieel Mohd
    Ghazaly, Mariam Md
    Ranom, Rahifa
    JURNAL TEKNOLOGI, 2015, 77 (20): : 67 - 74