Simultaneous T1 and T2 measurements using inversion recovery TrueFISP with principle component-based reconstruction, off-resonance correction, and multicomponent analysis

被引:10
|
作者
Pfister, Julian [1 ,2 ,3 ]
Blaimer, Martin [1 ]
Kullmann, Walter H. [3 ]
Bartsch, Andreas J. [4 ,5 ,6 ,7 ]
Jakob, Peter M. [2 ]
Breuer, Felix A. [1 ]
机构
[1] Fraunhofer Dev Ctr Xray Technol EZRT, Magnet Resonance & Xray Imaging Dept, D-97074 Wurzburg, Germany
[2] Univ Wurzburg, Dept Expt Phys 5, Wurzburg, Germany
[3] Univ Appl Sci Wurzburg Schweinfurt, Inst Med Engn Schweinfurt, Schweinfurt, Germany
[4] Heidelberg Univ, Dept Neuroradiol, Heidelberg, Germany
[5] Univ Hosp Wurzburg, Dept Neuroradiol, Wurzburg, Germany
[6] Univ Oxford, Dept Clin Neurol, WIN FMRIB Ctr, Oxford, England
[7] Radiol Bamberg, Bamberg, Germany
关键词
STEADY-STATE; GOLDEN-RATIO; TRANSIENT; QUANTIFICATION; BRAIN; TIME; OPTIMIZATION; SIGNAL;
D O I
10.1002/mrm.27657
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To improve the reconstruction quality for quantitative T-1 and T-2 measurements using the inversion recovery (IR) TrueFISP sequence and to demonstrate the potential for multicomponent analysis. Methods: The iterative reconstruction method takes advantage of the high redundancy in the smooth exponential signals using principle component analysis (PCA). Multicomponent information is preserved and allows voxel-by-voxel computation of relaxation time spectra with an inverse Laplace transform. Off-resonance effects are analytically and numerically investigated and a correction approach is presented. Results: Single-shot IR TrueFISP in vivo measurements on healthy volunteers demonstrate the improved reconstruction performance compared to a view sharing (k-space weighted image contrast [KWIC]) reconstruction. Especially, tissue components with short apparent relaxation times T-1(*) are not filtered out and can be identified in the relaxation time spectra. These components include myelin in the human brain (T-1(*) approximate to 130 ms) and extra cranial subcutaneous fat. Conclusion: The PCA-based reconstruction method improves the temporal accuracy and preserves multicomponent information. Spatially resolved relaxation time spectra can be obtained and allow the identification of tissue types with short, apparent relaxation times.
引用
收藏
页码:3488 / 3502
页数:15
相关论文
共 42 条
  • [21] Transverse Relaxation Time (T2) Mapping in the Brain With Off-Resonance Correction Using Phase-Cycled Steady-State Free Precession Imaging
    Deoni, Sean C. L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (02) : 411 - 417
  • [22] Identifying etiologies of heart failure using non-contrast cardiac magnetic resonance imaging: cine imaging, T1 and T2 mapping, and texture analysis for T1 mapping
    Amano, Yasuo
    Suzuki, Yasuyuki
    Tang, Xiaoyan
    Ando, Chisato
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2025, 11
  • [23] Validation of a T1 and T2* Leakage Correction Method Based on Multiecho Dynamic Susceptibility Contrast MRI Using MION as a Reference Standard
    Stokes, Ashley M.
    Semmineh, Natenael
    Quarles, C. Chad
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (02) : 613 - 625
  • [24] Robust motion correction for myocardial T1 and extracellular volume mapping by principle component analysis-based groupwise image registration
    Tao, Qian
    van der Tol, Pieternel
    Berendsen, Floris F.
    Paiman, Elisabeth H. M.
    Lamb, Hildo J.
    van der Geest, Rob J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (05) : 1397 - 1405
  • [25] Fast in vivo quantification of T1 and T2 MRI relaxation times in the myocardium based on inversion recovery SSFP with in vitro validation post Gd-based contrast administration
    Karmonik, Christof
    Malaty, Adam
    Bikram, Malavosklish
    Schmitt, Peter
    Partovi, Sasan
    Shah, Dipan J.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (02) : 88 - 96
  • [26] Direct determination of the heteronuclear T1/T2 ratio by off-resonance steady-state magnetization measurement: Investigation of the possible application to fast exchange characterization of 15N-labeled proteins
    Marc Guenneugues
    Patrick Berthault
    Hervé Desvaux
    Maurice Goldman
    Journal of Biomolecular NMR, 1999, 15 : 295 - 307
  • [27] Direct determination of the heteronuclear T1/T2 ratio by off-resonance steady-state magnetization measurement:: Investigation of the possible application to fast exchange characterization of 15N-labeled proteins
    Guenneugues, M
    Berthault, P
    Desvaux, H
    Goldman, M
    JOURNAL OF BIOMOLECULAR NMR, 1999, 15 (04) : 295 - 307
  • [28] Longitudinal Changes in Medial Meniscal Extrusion After ACL Injury and Reconstruction and Its Relationship With Cartilage Degeneration Assessed Using MRI-Based T1ρ and T2 Analysis
    Watanabe, Shotaro
    Joseph, Gabby B.
    Sato, Dai
    Lansdown, Drew A.
    Brandao Guimaraes, Julio
    Link, Thomas M.
    Ma, Chunbong Benjamin
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2025, 53 (02): : 350 - 359
  • [29] Improvement in the contrast-to-noise ratio and quantitative measurement of T1 and T2* values for carotid atherosclerotic plaque using multi-echo phase-sensitive inversion recovery
    Yasuhiro Fujiwara
    Motohira Mio
    Radiological Physics and Technology, 2021, 14 : 186 - 192
  • [30] Improvement in the contrast-to-noise ratio and quantitative measurement of T1 and T2* values for carotid atherosclerotic plaque using multi-echo phase-sensitive inversion recovery
    Fujiwara, Yasuhiro
    Mio, Motohira
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (02) : 186 - 192