Comparison of Low Frequency and High Frequency PD Measurements on Rotating Machine Stator Windings

被引:0
|
作者
Stone, G. C. [1 ]
Sedding, H. G. [1 ]
Chan, C. [1 ]
Wendel, C. [2 ]
机构
[1] Iris Power Qualitrol, Toronto, ON, Canada
[2] Iris Power Qualitrol, Brugg, Switzerland
关键词
partial discharge; measurement frequency; stator winding; electrical insulation; PARTIAL-DISCHARGE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) testing has been used for over 60 years primarily as a method to detect aging of the stator winding insulation in motors and generators rated 6 kV and above. More recently it has also been used by some machine manufacturers as a means of assuring the quality of the insulation. The PD measuring systems in use work either in the low frequency regime (less than about 1 MHz) or in the very high frequency (30-300 MHz) range. By reference to several international standards, published work as well as some experiments described here, the advantages and disadvantages of the two approaches are reviewed. In most circumstances it is now clear that off-line PD tests should be done in the low frequency range. For on-line tests, either frequency range can be used, but with different advantages.
引用
收藏
页码:349 / 352
页数:4
相关论文
共 50 条
  • [41] Induction Motor Stator Windings Asymmetry Influence on Frequency Converter Autonomous Voltage Inverter
    Zagirnyak, Mykhaylo
    Kalinov, Andrii
    Kostenko, Anna
    [J]. 2016 2ND INTERNATIONAL CONFERENCE ON INTELLIGENT ENERGY AND POWER SYSTEMS (IEPS), 2016,
  • [42] AC Losses in High Frequency Electrical Machine Windings formed from Large Section Conductors
    Mellor, Phil
    Wrobel, Rafal
    Simpson, Nick
    [J]. 2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 5563 - 5570
  • [43] Failure diagnosis of rotating machine by frequency modulation
    Goto, K
    Ishii, R
    [J]. PROCEEDINGS OF IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY 2000, VOLS 1 AND 2, 2000, : 376 - 381
  • [44] Stochastic analysis of partial discharges signals for diagnosis of insulation systems of AC rotating machine stator windings
    Contin, A
    Montanari, GC
    Cavallini, A
    Pasini, G
    Puletti, F
    [J]. IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 359 - 366
  • [45] Identification of slot discharges in rotating machine insulation system using variable frequency PD measurement
    Nair, Ramesh P.
    Vishwanath, Sumangala B.
    Rao, Nageshwar B.
    [J]. HIGH VOLTAGE, 2018, 3 (03): : 179 - 186
  • [46] Low frequency excess noise measurements in high frequency polysilicon emitter bipolar transistors
    Routoure, JM
    Lepaisant, J
    Bloyet, D
    Bardy, S
    Biard, C
    Gambus, L
    Lebailly, J
    [J]. SOLID-STATE ELECTRONICS, 1999, 43 (04) : 729 - 740
  • [47] Low frequency excess noise measurements in high frequency polysilicon emitter bipolar transistors
    Groupement de Rech. en Informatique, Intell. Artificielle Instrum. C., Caen, France
    不详
    [J]. Solid-State Electron, 4 (729-740):
  • [48] Statistical Deviation of High-Frequency Lumped Model Parameters for Stator Windings in Three-Phase Electrical Machines
    Hoffmann, Alexander
    Ponick, Bernd
    [J]. 2020 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM 2020), 2020, : 85 - 90
  • [49] A Novel Double Stator Flux Modulation Machine With Low-Temperature Superconducting Windings
    Gao, Yuting
    Li, Dawei
    Qu, Ronghai
    Ding, Han
    Kong, Wubin
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)
  • [50] High-frequency EMTP model of transformer windings
    Liang, Guishu
    Dong, Huaying
    Wang, Xiaohui
    Zhang, Xile
    Sun, Haifeng
    Cui, Xiang
    [J]. 2006 17TH INTERNATIONAL ZURICH SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, 2006, : 662 - +