Atrial fibrillation in elderly patients with implantable loop recorders for unexplained syncope

被引:6
|
作者
Arcinas, Liane A. [1 ]
McIntyre, William F. [2 ]
Hayes, Christopher J. [3 ]
Ibrahim, Omar A. [4 ]
Baranchuk, Adrian M. [4 ]
Seifer, Colette M. [3 ]
机构
[1] Univ Manitoba, Dept Internal Med, Winnipeg, MB, Canada
[2] McMaster Univ, Populat Hlth Res Inst, Hamilton, ON, Canada
[3] Univ Manitoba, Cardiol Sect, Dept Internal Med, Winnipeg, MB, Canada
[4] Queens Univ, Kingston Gen Hosp, Dept Cardiol, Kingston, ON, Canada
关键词
RISK;
D O I
10.1111/anec.12630
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background An implantable loop recorder (ILR) assists in the diagnosis of unexplained syncope and atrial fibrillation (AF). Both become prevalent with age. Limited data exist describing the incidence of AF as the diagnostic rhythm underlying syncope in the elderly. This study aims to report the incidence of AF in older adults with ILRs for unexplained syncope and identify clinical characteristics associated with AF in this population. Methods Retrospective observational study on patients with unexplained syncope seen in syncope clinics from two Canadian centers. Participants were >= 65 years old, without a history of AF, and received an ILR for unexplained syncope. Data were collected from patient's clinic charts. Arrhythmia diagnosis was based on ILR electrocardiogram reading during syncope (symptom-rhythm correlation). Fisher's exact test and the Student's t test were used to compare participants with and without AF. Results In our cohort of 222 patients, 124 were females and 98 were males. Mean age at implant was 80 +/- 8 years. Arrhythmia was diagnosed in 98 patients (44.1%). Median time to diagnosis was 18 months. AF was diagnosed in 17 (7.7%) participants. There were fewer males in the AF group than the no AF group (11.8%, 46.8%, p = 0.01). Age, baseline EKG, and prevalence of hypertension, diabetes, stroke, or ischemic heart disease were not statistically different between patients with AF and without AF. Conclusions Atrial fibrillation was a common diagnostic rhythm in this cohort of adults, aged 65 and older, with ILRs for unexplained syncope. It was observed more frequently in females.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Detection of atrial fibrillation in patients with embolic stroke of undetermined source by prolonged monitoring with implantable loop recorders
    Israel, Carsten
    Kitsiou, Alkisti
    Kalyani, Malik
    Deelawar, Sameera
    Ejangue, Lucy Ekosso
    Rogalewski, Andreas
    Hagemeister, Christoph
    Minnerup, Jens
    Schaebitz, Wolf-Ruediger
    [J]. THROMBOSIS AND HAEMOSTASIS, 2017, 117 (10) : 1962 - 1969
  • [42] Implantable Loop Recorders in Contemporary Practice: Can Clinical or Ecg Findings Predict an Arrhythmic Origin for Unexplained Syncope?
    Ho, Rady
    Marks, Daniel
    Russo, Andrea M.
    Andriulli, John
    Ortman, Matthew
    [J]. CIRCULATION, 2019, 140
  • [43] Atrial Fibrillation Detection (Incidence And Accuracy) By Implantable Loop Recorders For The Indications: Cryptogenic Stroke, Syncope, Or Palpitations: A Real World Cohort Study
    Klinkhammer, Brent
    Gayed, Noha
    Jamal, Sameer
    Glotzer, Taya V.
    [J]. CIRCULATION, 2022, 146
  • [44] POTENTIAL COST-SAVINGS USING IMPLANTABLE LOOP RECORDERS (ILRS) FOR UNEXPLAINED SYNCOPE DIAGNOSTICS: THE CASE FOR THE NETHERLANDS
    Van Genugten, M.
    Tsintzos, S.
    [J]. VALUE IN HEALTH, 2009, 12 (07) : A254 - A254
  • [45] Paroxysmal bradyarrhythmias are frequent among heart transplant recipients with unexplained syncope: a study based on implantable loop recorders
    Martinez-Paz, Emilse
    Barge-Caballero, Eduardo
    Alvarez-Roy, Laura
    Barge-Caballero, Gonzalo
    Couto-Mallon, David
    Paniagua-Martin, Maria J.
    Mosquera-Perez, Ignacio
    Perez-Alvarez, Luisa
    Muniz, Javier
    Cuenca-Castillo, Jose J.
    Manuel Vazquez-Rodriguez, Jose
    Crespo-Leiro, Maria G.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 (03) : 616 - +
  • [46] Value of Implantable Loop Recorders in Monitoring Efficacy of Radiofrequency Catheter Ablation in Atrial Fibrillation
    Yang, Ping
    Pu, Lijin
    Yang, Liuqing
    Li, Fang
    Luo, Zhiling
    Guo, Tao
    Hua, Baotong
    Li, Shumin
    [J]. MEDICAL SCIENCE MONITOR, 2016, 22 : 2846 - 2851
  • [47] Paroxysmal atrial fibrillation as a cause of unexplained syncope
    Hemmi, Heisuke
    Kataoka, Naoya
    Imamura, Teruhiko
    [J]. JOURNAL OF CARDIOLOGY, 2022, 80 (04) : 373 - 373
  • [48] Atrial fibrillation post central retinal artery occlusion: Role of implantable loop recorders
    Watson, Ryan A.
    Wellings, Jennifer
    Hingorani, Rittu
    Zhan, Tingting
    Frisch, Daniel R.
    Ho, Reginald T.
    Pavri, Behzad B.
    Sergott, Robert C.
    Greenspon, Arnold J.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (09): : 992 - 999
  • [49] The Implantable Loop Recorder in a Case of Recurrent Unexplained Syncope
    Lau, Clement
    Redgrave, Lisa
    Kayan, Karthik
    [J]. JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2012, 60 (02) : 369 - 370
  • [50] Remote monitoring of implantable loop recorders reduces time to diagnosis in patients with unexplained syncope: a multicenter propensity score-matched study
    Russo, Vincenzo
    Rago, Anna
    Grimaldi, Nicola
    Chianese, Raffaele
    Viggiano, Aniello
    D'Alterio, Giuliano
    Colonna, Diego
    Mattera Iacono, Agostino
    Papa, Andrea Antonio
    Spadaro Guerra, Andrea
    Gargaro, Alessio
    Rapacciuolo, Antonio
    Sarubbi, Berardo
    D'Onofrio, Antonio
    Nigro, Gerardo
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10