Clinical investigation of G-Bond resin-based adhesive to non-carious cervical lesions over five years

被引:8
|
作者
Burrow, M. F. [1 ,2 ]
Tyas, M. J. [2 ]
机构
[1] Univ Hong Kong, Prince Philip Dent Hosp, Fac Dent, Hong Kong, Hong Kong, Peoples R China
[2] Univ Melbourne, Melbourne Dent Sch, Carlton, Vic 3053, Australia
关键词
Resin-based adhesive; clinical trial; non-carious cervical lesions; dentine bonding; IN-ONE ADHESIVE; SELF-ETCH ADHESIVE; ONE-STEP ADHESIVES; HEMA-FREE; DENTIN; TRIAL; STRENGTH; ENAMEL; DEGRADATION; PERFORMANCE;
D O I
10.1111/j.1834-7819.2012.01729.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The aim of this study was to evaluate the clinical performance of G-Bond all-in-one adhesive with Gradia Direct resin composite placed in non-carious cervical lesions (NCCLs) over a five-year period. Methods: Forty-seven restorations were placed in NCCLs in 10 subjects (age 4575 years) after written informed consent was obtained. Institutional ethical approval for the trial was obtained before recruitment. Restorations were placed according to the manufacturers instructions and using 50% phosphoric acid to etch uncut enamel margins. Patients were recalled annually for five years and restorations reviewed for presence and marginal staining. Photographic records were obtained prior to restoration, immediately after placement and at each recall. Results: At five years, 6 of the original 10 subjects were available for recall, meaning 27 restoration sites could be evaluated. All restorations remained intact apart for one partial failure at four years. This resulted in a cumulative retention rate of 97.5% of restorations at five years. Marginal staining occurred around seven restorations during the study. Staining tended to be isolated to a few patients. Conclusions: It was concluded that G-Bond with Gradia Direct resin composite showed excellent results over the five years of the study. This material combination seems very suitable for the restoration of NCCLs.
引用
收藏
页码:458 / 463
页数:6
相关论文
共 50 条
  • [1] Clinical trial of G-Bond all-in-one adhesive and Gradia Direct resin composite in non-carious cervical lesions - Results at 1 year
    Burrow, M. F.
    Tyas, M. J.
    [J]. JOURNAL OF DENTISTRY, 2007, 35 (07) : 623 - 625
  • [2] Clinical evaluation of a universal adhesive in non-carious cervical lesions
    Rouse, Matthew A.
    May, Jaren T.
    Platt, Jeffrey A.
    Cook, N. Blaine
    Capin, Oriana R.
    Adams, Brooke N.
    Kirkup, Michele L.
    Diefenderfer, Kim E.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (07) : 691 - 698
  • [3] Five-year clinical evaluation of two adhesive systems in non-carious cervical lesions
    Kubo, S
    Kawasaki, K
    Yokota, H
    Hayashi, Y
    [J]. JOURNAL OF DENTISTRY, 2006, 34 (02) : 97 - 105
  • [4] Clinical evaluation of a self-etch adhesive in non-carious cervical lesions
    Abdalla, Ali I.
    El Sayed, Hussein Y.
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2008, 21 (05): : 327 - 330
  • [5] Clinical evaluation of three adhesive systems for the restoration of non-carious cervical lesions
    Burrow, M. F.
    Tyas, M. J.
    [J]. OPERATIVE DENTISTRY, 2007, 32 (01) : 11 - 15
  • [6] Five-year clinical evaluation of One-Up Bond F in non-carious cervical lesions
    Burrow, Michael F.
    Tyas, Martin J.
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2007, 20 (06): : 361 - 364
  • [7] Flowable composites for restoration of non-carious cervical lesions: Results after five years
    Cieplik, Fabian
    Scholz, Konstantin J.
    Tabenski, Isabelle
    May, Sabine
    Hiller, Karl-Anton
    Schmalz, Gottfried
    Buchalla, Wolfgang
    Federlin, Marianne
    [J]. DENTAL MATERIALS, 2017, 33 (12) : E428 - E437
  • [8] Clinical effectiveness of a one-step self-etch adhesive in non-carious cervical lesions at 2 years
    Ermis, R. Banu
    Van Landuyt, Kirsten L.
    Cardoso, Marcio Vivan
    De Munck, Jan
    Van Meerbeek, Bart
    Peumans, Marleen
    [J]. CLINICAL ORAL INVESTIGATIONS, 2012, 16 (03) : 889 - 897
  • [9] Two-year clinical evaluation of three adhesive systems in non-carious cervical lesions
    Dalkilic, Evrim Eliguzeloglu
    Omurlu, Huma
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (02) : 192 - 199
  • [10] Clinical effectiveness of a one-step self-etch adhesive in non-carious cervical lesions at 2 years
    R. Banu Ermis
    Kirsten L. Van Landuyt
    Marcio Vivan Cardoso
    Jan De Munck
    Bart Van Meerbeek
    Marleen Peumans
    [J]. Clinical Oral Investigations, 2012, 16 : 889 - 897