Application of Dynamic Models to predict Switching Impulse Withstand Voltages of Long Air Gaps

被引:17
|
作者
Fofana, I. [1 ]
Beroual, A. [2 ]
Rakotonandrasana, J-H. [2 ]
机构
[1] Univ Quebec Chicoutimi, ISOLIME, Chicoutimi, PQ, Canada
[2] Ecole Cent Lyon, AMPERE Lab, CNRS UMR 5005, F-69134 Ecully, France
关键词
Long air gap discharge; mathematical modeling; computer simulation; critical flashover voltage (CFOV); DISCHARGE;
D O I
10.1109/TDEI.2013.6451345
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this paper is to study the critical breakdown voltage or U-50 - corresponding to the 50% probability of breakdown for a single impulse application - of long air-gaps under positive and negative switching impulse voltages, using predictive dynamic models. The knowledge of this important parameter is of practical interest to the design engineer. The models previously developed by the authors are based on equivalent electrical network, gas discharge theories and physical laws. Various gap geometry and atmospheric conditions were considered. The U-50, determined using the up and down method along with other important parameters, were compared to experimental data. Good agreements were found between simulated and experimental results. The results obtained indicate that U-50 prediction is possible, using the proposed models. Knowledge of the gap factor and weather conditions might help applying corrections to determine the breakdown strength under various conditions. These dynamic models might therefore be useful to estimate the required clearances of air gaps in the preliminary design phase over a wide range of geometry and some atmospheric factors; therefore reducing the required full-scale testing.
引用
收藏
页码:89 / 97
页数:9
相关论文
共 50 条
  • [21] Behaviour of positive conductor-rod gaps stressed by impulse voltages in atmospheric air
    Gourgoulis, DE
    Mikropoulos, PN
    Stassinopoulos, CA
    Yakinthos, CG
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1997, 144 (05) : 209 - 214
  • [22] INFLUENCE OF DESERT POLLUTION ON THE LIGHTNING IMPULSE BREAKDOWN VOLTAGES OF ROD TO PLANE AIR GAPS
    ALARAINY, AA
    MALIK, NH
    QURESHI, MI
    IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (01) : 421 - 428
  • [23] BEHAVIOR OF AIR INSULATING GAPS OF DC SYSTEMS UNDER IMPULSE, DC AND COMPOSITE VOLTAGES
    MENEMENLIS, C
    HARBEC, G
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (06): : 2065 - 2075
  • [24] ANALYSIS OF SWITCHING IMPULSE STRENGTH OF PHASE-TO-PHASE AIR GAPS
    GALLET, G
    HUTZLER, B
    RIU, JP
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (02): : 485 - 494
  • [25] Switching impulse discharge characteristics of UHV transmission line air gaps
    Gao, Jiachen
    Wang, Linong
    Zhang, Qiushi
    Song, Bin
    Liu, Kai
    Xiao, Bin
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 14 (05) : 735 - 741
  • [26] IMPULSE FLASHOVER CHARACTERISTICS OF LONG AIR GAPS AND ATMOSPHERIC CORRECTION
    AIHARA, Y
    HARADA, T
    AOSHIMA, Y
    ITO, Y
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (02): : 342 - 348
  • [27] Optimization of Corona Onset and Breakdown Voltage of Small Air Gaps Stressed by DC and Impulse Voltages
    Maglaras, Athanasios
    Kousiouris, Trifon
    Topalis, Frangiskos
    Maglaras, Leandros A.
    Giannakopoulou, Konstantina
    2013 IEEE EUROCON, 2013, : 1206 - 1213
  • [28] Critical switching impulse breakdown of long bundle-conductor gaps
    Rizk, FAM
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) : 373 - 383
  • [29] FACTORS INFLUENCING SPARKOVER OF LARGE GAPS IN AIR WHEN STRESSED WITH IMPULSE VOLTAGES EFFECTS OF RADIATION
    ALLIBONE, TE
    DRING, D
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1974, PA93 (06): : 1730 - 1730
  • [30] Switching surge breakdown voltage of long air gaps
    Chen, Daohui
    Bianyaqi/Transformer, 34 (10): : 1 - 4