Validation of a bone loading estimation algorithm for patient-specific bone remodelling simulations

被引:29
|
作者
Christen, Patrik [1 ]
Ito, Keita [1 ]
dos Santos, Andreia Andrade [1 ]
Mueller, Ralph [2 ]
van Rietbergen, Bert [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[2] ETH, Inst Biomech, Zurich, Switzerland
关键词
Bone loading estimation; Patient-specific bone remodelling simulation; Bone adaptation; TRABECULAR BONE; CANCELLOUS BONE; COMPUTED-TOMOGRAPHY; PROXIMAL FEMUR; ADAPTATION; STRAIN; MICROARCHITECTURE; MAINTENANCE; MICRODAMAGE; PROPOSAL;
D O I
10.1016/j.jbiomech.2012.12.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Patient-specific simulations of bone remodelling could enable predicting how bone micro-structural integrity would be affected by bone diseases, drugs or other factors, and, ultimately could help clinicians to improve their prognoses. To simulate load-adaptive remodelling, however, knowledge about the physiological external loading acting on the bone is required. Assuming that load adaptation leads to homogeneous tissue loading, we previously developed a method to estimate the physiological loading history from bone micro-structural morphology. We were able to reconstruct the loading history of a simple load case that was applied in an animal experiment. However, we found considerable inhomogeneity in tissue loading suggesting that the bones were not fully adapted. Also, we noted differences in bone micro-architecture between animals despite common loading history, possibly due to differences caused by the stochastic nature of the bone remodelling process. In the present study, we aim at validating the load estimation algorithm in a well-controlled environment in which more complicated loading conditions are applied. Specifically, we want to test its accuracy for partially and fully developed bone structures and for differences in bone micro-architectures as they can occur due to stochastic events, even for bones with a common loading history. This was possible by using synthetic micro-architectures obtained from bone remodelling simulations as the basis for our load estimation algorithm. Loading histories based on fully adapted structures were predicted with a maximum error of 4.4% and predictions were not affected by differences in bone micro-architecture. These results show that our load estimation algorithm produces reasonable predictions and might be a suitable tool to define in vivo loading for patient-specific bone remodelling studies. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 50 条
  • [41] Fabrication of individual scaffolds based on a patient-specific alveolar bone defect model
    Li, Jinghui
    Zhang, Lei
    Lv, Shengyi
    Li, Shengjie
    Wang, Na
    Zhang, Zhenting
    JOURNAL OF BIOTECHNOLOGY, 2011, 151 (01) : 87 - 93
  • [42] Intraoperative template-molded bone flap reconstruction for patient-specific cranioplasty
    Marbacher, Serge
    Andereggen, Lukas
    Erhardt, Salome
    Fathi, Ali-Reza
    Fandino, Javier
    Raabe, Andreas
    Beck, Juergen
    NEUROSURGICAL REVIEW, 2012, 35 (04) : 527 - 535
  • [43] On-chip recapitulation of clinical bone marrow toxicities and patient-specific pathophysiology
    David B. Chou
    Viktoras Frismantas
    Yuka Milton
    Rhiannon David
    Petar Pop-Damkov
    Douglas Ferguson
    Alexander MacDonald
    Özge Vargel Bölükbaşı
    Cailin E. Joyce
    Liliana S. Moreira Teixeira
    Arianna Rech
    Amanda Jiang
    Elizabeth Calamari
    Sasan Jalili-Firoozinezhad
    Brooke A. Furlong
    Lucy R. O’Sullivan
    Carlos F. Ng
    Youngjae Choe
    Susan Marquez
    Kasiani C. Myers
    Olga K. Weinberg
    Robert P. Hasserjian
    Richard Novak
    Oren Levy
    Rachelle Prantil-Baun
    Carl D. Novina
    Akiko Shimamura
    Lorna Ewart
    Donald E. Ingber
    Nature Biomedical Engineering, 2020, 4 : 394 - 406
  • [44] Patient-specific bone modeling and analysis: The role of integration and automation in clinical adoption
    Zadpoor, Amir A.
    Weinans, Harrie
    JOURNAL OF BIOMECHANICS, 2015, 48 (05) : 750 - 760
  • [45] Synthetic skull bone defects for automatic patient-specific craniofacial implant design
    Jianning Li
    Christina Gsaxner
    Antonio Pepe
    Ana Morais
    Victor Alves
    Gord von Campe
    Jürgen Wallner
    Jan Egger
    Scientific Data, 8
  • [46] Multi-Criteria Evaluation of Design Complexity for Patient-Specific Bone Graft
    Agarski, Boris
    Sokac, Mario
    Santosi, Zeljko
    Vukelic, Djordje
    Budak, Igor
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2020, 27 (03): : 803 - 811
  • [47] The Effectiveness of Percutaneous Vertebroplasty Is Determined by the Patient-Specific Bone Condition and the Treatment Strategy
    Soyka, Rene P. Widmer
    Helgason, Benedikt
    Marangalou, Javad Hazrati
    van den Bergh, Joop P.
    van Rietbergen, Bert
    Ferguson, Stephen J.
    PLOS ONE, 2016, 11 (04):
  • [48] Patient-Specific Phantomless Estimation of Bone Mineral Density and Its Effects on Finite Element Analysis Results: A Feasibility Study
    Lee, Young Han
    Kim, Jung Jin
    Jang, In Gwun
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2019, 2019
  • [49] The effect of muscle loading on the simulation of bone remodelling in the proximal femur
    Bitsakos, C
    Kerner, J
    Fisher, I
    Amis, AA
    JOURNAL OF BIOMECHANICS, 2005, 38 (01) : 133 - 139
  • [50] Modular design workflow for 3D printable bioresorbable patient-specific bone scaffolds: extended features and clinical validation
    Herath, Buddhi
    Laubach, Markus
    Suresh, Sinduja
    Schmutz, Beat
    Little, J. Paige
    Yarlagadda, Prasad K. D. V.
    Delbrueck, Heide
    Hildebrand, Frank
    Hutmacher, Dietmar W.
    Wille, Marie-Luise
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12