Can the use of an inclinometer improve acetabular cup inclination in total hip arthroplasty? A review of the literature

被引:9
|
作者
van Duren, Bernard H. [1 ]
Royeca, Joseph M. [2 ]
Cunningham, Conor M. [3 ]
Lamb, Jonathan N. [1 ]
Brew, Chris J. [2 ]
Pandit, Hemant [1 ]
机构
[1] Univ Leeds, Leeds Inst Rheumat & Musculoskeletal Med, Leeds Orthopaed & Trauma Sci, Leeds, W Yorkshire, England
[2] Bradford Royal Infirm, Bradford, W Yorkshire, England
[3] Indiana Univ Sch Med, W Lafayette, IN USA
关键词
Acetabular component orientation; inclinometer; operative inclination; radiographic inclination; total hip arthroplasty; COMPONENT POSITION; SAFE ZONE; REPLACEMENT; ORIENTATION; DISLOCATION; PLACEMENT; REVISION; OFFSET; RISK; WEAR;
D O I
10.1177/1120700020946716
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: The angle of acetabular (cup) radiographic inclination is an important measurement in total hip arthroplasty (THA) procedures. Abnormal radiographic inclination is associated with dislocation, edge loading and higher failure rates. Consistently achieving a satisfactory radiographic inclination remains a challenge. Inclinometers have been increasingly used over the last decade. This paper reviews the literature to determine whether using an inclinometer improves the accuracy of acetabular cup inclination in THA. Methods: A systematic literature search was performed. The following search terms were used: ('hip' OR 'hip replacement' OR 'hip arthroplasty' OR 'primary hip replacement' OR 'THR' OR 'THA' OR 'Acetabular cup Inclination') AND ('Inclinometer'). Titles and abstracts were screened for relevance. Both radiographic and operative inclination comparisons were included. Results: 7 studies met the inclusion criteria. 2 were randomised control trials with level I evidence, and the remaining studies were cohort studies with level III/IV evidence. 5 were clinical and 2 experimental. In total there were 16 cohorts: 7 using an inclinometer, 6 freehand, and 3 using MAG techniques. All studies comparing radiographic inclination and 1 of 2 studies comparing operative inclination showed an improvement in the attainment of the optimal inclination. Similarly, the use of an inclinometer showed a reduction in the number of outliers when compared to MAG and freehand techniques. Discussion: This review demonstrates that using an inclinometer improved the surgeon's ability to achieve their intended inclination (both operative and radiographic) and reduced the incidence of positioning outside the safe-zone. However, only 2 of the studies were randomised control trials and these resulted in opposing conclusions. Therefore, further studies looking at the use of inclinometers would prove useful in understanding their true benefit.
引用
收藏
页码:609 / 617
页数:9
相关论文
共 50 条
  • [21] Effects of acetabular abduction on cup wear rates in total hip arthroplasty
    Del Schutte, H
    Lipman, AJ
    Bannar, SM
    Livermore, JT
    Ilstrup, D
    Morrey, BF
    JOURNAL OF ARTHROPLASTY, 1998, 13 (06): : 621 - 626
  • [22] Effect of acetabular cup position and orientation in cemented total hip arthroplasty
    Hirakawa, K
    Mitsugi, N
    Koshino, T
    Saito, T
    Hirasawa, Y
    Kubo, T
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 135 - 142
  • [23] Precision of acetabular cup placement in robotic integrated total hip arthroplasty
    Elson, Leah
    Dounchis, Jon
    Illgen, Richard
    Marchand, Robert C.
    Padgett, Douglas E.
    Bragdon, Charles R.
    Malchau, Henrik
    HIP INTERNATIONAL, 2015, 25 (06) : 531 - 536
  • [24] Oblong Acetabular Cup, Type TC, for Revision Total Hip Arthroplasty
    Trc, T.
    Stastny, E.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (06) : 506 - 511
  • [25] Research Synthesis of Recommended Acetabular Cup Orientations for Total Hip Arthroplasty
    Harrison, Claire L.
    Thomson, Avril I.
    Cutts, Steven
    Rowe, Philip J.
    Riches, Philip E.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 377 - 382
  • [26] Biomechanical Evaluation of Acetabular Cup Implantation in Cementless Total Hip Arthroplasty
    Margalit, Kate A.
    Hayashi, Kei
    Jackson, Josh
    Kim, Sun Young
    Garcia, Tanya C.
    Wiggans, K. Tomo
    Aiken, Sean
    Stover, Susan M.
    VETERINARY SURGERY, 2010, 39 (07) : 818 - 823
  • [27] Acetabular Cup Design Influences Deformational Response in Total Hip Arthroplasty
    Meding, John B.
    Small, Scott R.
    Jones, Mary E.
    Berend, Michael E.
    Ritter, Merrill A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (02) : 403 - 409
  • [28] ACETABULAR CUP-SITING DEVICE FOR TOTAL HIP-ARTHROPLASTY
    DOYLE, J
    MURRAY, P
    MAHONY, PO
    FARMER, M
    HOOPER, AC
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1989, 108 (05) : 317 - 321
  • [29] Acetabular cup positioning in primary routine total hip arthroplasty—a review of current concepts and technologies
    Aravind Sai Sathikumar
    George Jacob
    Appu Benny Thomas
    Jacob Varghese
    Venugopal Menon
    Arthroplasty, 5
  • [30] Total hip arthroplasty: to cement or not to cement the acetabular socket? A critical review of the literature
    Clement, N. D.
    Biant, L. C.
    Breusch, S. J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (03) : 411 - 427