Dynamic Responses of Sliding Isolation Concrete Liquid Storage Tank under Far-Field Long-Period Earthquake

被引:10
|
作者
Jing, W. [1 ,2 ]
Cheng, X. [1 ,2 ]
机构
[1] Lanzhou Univ Technol, Key Lab Disaster Prevent & Mitigat Civil Engn Gan, Lanzhou 730050, Gansu, Peoples R China
[2] Lanzhou Univ Technol, Western Engn Res Ctr Disaster Mitigat Civil Engn, Minist Educ, Lanzhou 730050, Gansu, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Sliding isolation; Concrete rectangular liquid storage tank (CRLST); Far-field long-period ground motion; Fluid-structure interaction; Liquid sloshing; FLUID-STRUCTURE-INTERACTION; BEHAVIOR;
D O I
10.29252/jafm.12.03.29180
中图分类号
O414.1 [热力学];
学科分类号
摘要
Under far-field long-period earthquake, liquid storage tanks are easy to be failure because of large amplitude liquid sloshing. In this paper, nonlinear contact is used to simulate behavior of sliding isolation bearing, nonlinear dynamic equation is used to solve fluid-structure interaction, bilinear material model is used to simulate limiting-device, and 3-D calculation model of sliding isolation concrete rectangular liquid storage tank (CRLST) with limiting-devices is established. Firstly, artificial far-field long-period earthquake waves are synthesized based on the existing seismic records. Secondly, dynamic responses of sliding isolation CRLST under the action of short-period and far-field long-period earthquakes are studied. Thirdly, effects of bidirectional earthquake and structure size on dynamic responses are investigated. Lastly, displacement control measures are discussed. Results show that far-field long-period earthquakes mainly affect horizontal displacement of structure and liquid sloshing wave height, and sliding isolation has obvious control effect on liquid sloshing wave height. Besides, horizontal displacement of structure and liquid sloshing wave height are increased with increase of seismic dimension and structure size. The reasonable designs of sliding isolation bearing and limiting-device can solve the problem that the maximum horizontal displacement of sliding isolation CRLST may exceed the limit under far-field long-period earthquake.
引用
收藏
页码:907 / 919
页数:13
相关论文
共 35 条
  • [31] Response analysis of large-span spatial seismic isolation structures under three-dimensional long-period earthquake actions
    Li, Xiaopeng
    He, Qing
    Ling, Kangjie
    Zhou, Jiayu
    Liu, Dewen
    STRUCTURES, 2025, 73
  • [32] Dynamic responses of base-isolated concrete liquid storage structure under two types of resonances
    Jing, Wei
    Wang, Jingxuan
    JOURNAL OF VIBROENGINEERING, 2019, 21 (06) : 1574 - 1586
  • [33] Dynamic Responses of Liquid Storage Tank Under Near Fault Pulse-Like Earthquakes With Different Focal Mechanisms
    Jing, Wei
    Shen, Jian
    Cheng, Xuansheng
    INTERNATIONAL JOURNAL OF ACOUSTICS AND VIBRATION, 2022, 27 (02): : 151 - 161
  • [34] Optimization of Seismic Isolation Bearing Scheme of RC Long-Span Soft Arch Bridge under Near-Field and Far-Field Ground Motions
    Shao C.
    Cui H.
    Qi Q.
    Wei W.
    Zhuang W.
    Huang H.
    Yuan D.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2024, 59 (03): : 615 - 626
  • [35] Seismic fragility and damage assessment of reinforced concrete bridge pier under long-duration, near-fault, and far-field ground motions
    Todorov, Borislav
    Billah, A. H. M. Muntasir