Cardiac implantable electronic device-related endocarditis: A 12-year single-centre experience

被引:5
|
作者
Whitaker, John
Williams, Steven
Arujuna, Aruna
Rinaldi, C. Aldo
Chambers, John
Klein, John L. [1 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Directorate Infect, St Thomas Hosp, London SE1 7EH, England
关键词
Pacemaker; endocarditis; UK; management; PACEMAKER-RELATED ENDOCARDITIS; INFECTIVE ENDOCARDITIS; CLINICAL PRESENTATION; MANAGEMENT;
D O I
10.3109/00365548.2012.701015
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: The incidence of cardiac implantable electrical device endocarditis (CIEDE) is increasing, but CIEDE remains a relatively poorly described infection. This case series describes our experience of the condition at a tertiary referral centre in London over a 12-y period. Methods: We identified cases using an endocarditis database containing prospectively collected clinical and microbiological information. We also used data recorded in an electronic database of all cardiac implantable electrical device-related procedures. Results: Thirty cases of CIEDE were treated at our institution during the study period. Presentation was most commonly with fever, and 93% of our patients had positive blood cultures. Vegetations were identified on echocardiography in only 70% of patients, although a transoesophageal echocardiogram (TOE) was performed in only half of the cases. Sixty-seven percent of our cases were defined as definite endocarditis according to the modified Duke criteria for infective endocarditis. Twenty-three patients underwent percutaneous explantation of their infected CIED (including 6 patients with vegetations greater than 10 mm in diameter), while 5 underwent surgical explantation. The overall in-hospital mortality was 17%. Conclusions: Our data confirm the life-threatening nature of CIEDE in a UK population. In addition, our experience suggests that percutaneous extraction of devices with large adherent vegetations may be safe, and that the selective use of TOE may not compromise outcomes. Lastly, we show that the modified Duke criteria do not perform very well with this condition, suggesting a need for specific, validated criteria for diagnosing CIEDE.
引用
收藏
页码:922 / 926
页数:5
相关论文
共 50 条
  • [1] A 6-year analysis of cardiovascular implantable electronic device-related endocarditis Lead endocarditis
    Erdem, Hasan
    Kaya, Sibel Dogan
    [J]. ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2023, 14
  • [2] The Natural History and Treatment of Cardiac Implantable Electronic Device Associated PneumothoraxdA 10-Year Single-Centre Experience
    Thomas, Garry R.
    Kumar, Sharath K.
    Turner, Suzette
    Moussa, Fuad
    Singh, Sheldon M.
    [J]. CJC OPEN, 2021, 3 (02) : 176 - 181
  • [3] High-Dose Daptomycin for Cardiac Implantable Electronic Device-Related Infective Endocarditis
    Durante-Mangoni, Emanuele
    Casillo, Roberta
    Bernardo, Mariano
    Caianiello, Cristina
    Mattucci, Irene
    Pinto, Daniela
    Agrusta, Federica
    Caprioli, Roberta
    Albisinni, Rosina
    Ragone, Enrico
    Utili, Riccardo
    [J]. CLINICAL INFECTIOUS DISEASES, 2012, 54 (03) : 347 - 354
  • [4] Tricuspid valve surgery in implantable cardiac electronic device-related endocarditis: Repair or replace?
    Cakici, Mehmet
    Ozcinar, Evren
    Baran, Cagdas
    Gumus, Fatih
    Durdu, Mustafa Serkan
    Inan, Mustafa Bahadir
    Eryilmaz, Sadik
    Akar, Ahmet Ruchan
    [J]. TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 26 (02): : 183 - 191
  • [5] Cardiac implantable electronic device implantation and device-related infection
    Modi, Vivek
    Shah, Kashyap
    Ferraro, Bruce
    Gasimli-Gamache, Leyla
    Nanda, Sudip
    Stevens, Steven
    Shirani, Jamshid
    [J]. EUROPACE, 2023, 25 (09):
  • [6] Multiple osteochondromas (MO) in the forearm: a 12-year single-centre experience
    Ham, John
    Flipsen, Mark
    Koolen, Marianne
    van der Zwan, Arnard
    Mader, Konrad
    [J]. STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2016, 11 (03): : 169 - 175
  • [7] Outcomes in cardiac implantable electronic device-related infective endocarditis: a systematic review of current literature
    Sanghavi, Ria
    Ravikumar, Nidhruv
    Sarodaya, Varun
    Haq, Mawiyah
    Sherif, Mohamed
    Harky, Amer
    [J]. FUTURE CARDIOLOGY, 2022, 18 (11) : 891 - 899
  • [8] A single centre retrospective analysis of the management and outcomes of cardiac device-related infective endocarditis
    Shanks, G.
    Butt, H.
    Jennings, R.
    Waddingham, P.
    Bvekerwa, I.
    Bhattacharyya, S.
    Davies, C.
    Menezes, L.
    Ambekar, S.
    Uppal, R.
    Suarez, C.
    Das, S.
    Woldman, S.
    Chow, A.
    Primus, C.
    [J]. EUROPEAN HEART JOURNAL, 2023, 44
  • [9] Clinical Predictors of Cardiovascular Implantable Electronic Device-Related Infective Endocarditis
    Le, Katherine Y.
    Sohail, Muhammad R.
    Friedman, Paul A.
    Uslan, Daniel Z.
    Cha, Stephen S.
    Hayes, David L.
    Wilson, Walter R.
    Steckelberg, James M.
    Baddour, Larry M.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (04): : 450 - 459
  • [10] Cardiac device-related endocarditis: 31-Years' experience
    Osmonov, Damirbek
    Ozcan, Kazim Serhan
    Erdinler, Izzet
    Altay, Servet
    Yildirim, Ersin
    Turkkan, Ceyhan
    Ekmekci, Ahmet
    Gungor, Baris
    Gurkan, Kadir
    [J]. JOURNAL OF CARDIOLOGY, 2013, 61 (1-2) : 175 - 180