Cardiac implantable electronic device implantation and device-related infection

被引:5
|
作者
Modi, Vivek [1 ]
Shah, Kashyap [1 ]
Ferraro, Bruce [1 ]
Gasimli-Gamache, Leyla [1 ]
Nanda, Sudip [1 ]
Stevens, Steven [1 ]
Shirani, Jamshid [1 ]
机构
[1] St Lukes Univ Hlth Network, Heart & Vasc Ctr, Dept Cardiol, 801 Ostrum St, Bethlehem, PA 18015 USA
来源
EUROPACE | 2023年 / 25卷 / 09期
关键词
Cardiac implantable electronic device; Device-related infection; Prognosis; Mortality; Cost; Length of stay; UNITED-STATES; CARDIOVERTER-DEFIBRILLATORS; RESYNCHRONIZATION THERAPY; EUROPEAN-SOCIETY; LEAD EXTRACTION; TASK-FORCE; TRENDS; ASSOCIATION; GUIDELINES; MANAGEMENT;
D O I
10.1093/europace/euad208
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Cardiac implantable electronic devices (CIED) are important tools for managing arrhythmias, improving hemodynamics, and preventing sudden cardiac death. Device-related infections (DRI) remain a significant complication of CIED and are associated with major adverse outcomes. We aimed to assess the trend in CIED implantations, and the burden and morbidity associated with DRI. Methods and results The 2011-2018 National Inpatient Sample database was searched for admissions for CIED implantation and DRI. A total of 1 604 173 admissions for CIED implantations and 71 007 (4.4%) admissions for DRI were reported. There was no significant change in annual admission rates for DRI (3.96-4.59%, P value for trend = 0.98). Those with DRI were more likely to be male (69.3 vs. 57%, P < 0.001) and have a Charlson comorbidity index score & GE;3 (46.6 vs. 36.8%, P < 0.001). The prevalence of congestive heart failure (CHF) increased in those admitted with DRI over the observation period. Pulmonary embolism, deep vein thrombosis, and post-procedural hematoma were the most common complications in those with DRI (4.1, 3.6, and 2.90%, respectively). Annual in-hospital mortality for those with DRI ranged from 3.9 to 5.8% (mean 4.4%, P value for trend = 0.07). Multivariate analysis identified CHF [odds ratio (OR) = 1.67; 95% confidence interval (CI) = 1.35-2.07], end-stage renal disease (OR = 1.90; 95% CI = 1.46-2.48), coagulopathy (OR = 2.94; 95% CI = 2.40-3.61), and malnutrition (OR = 2.50; 95% CI = 1.99-3.15) as the predictors of in-hospital mortality for patients admitted with DRI. Conclusion Device-related infection is relatively common and continues to be associated with high morbidity and mortality. The prevalence of DRI has not changed significantly despite technical and technological advances in cardiac devices and their implantation.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Cardiac Implantable Electronic Device-Related Infection Due to Granulicatella adiacens
    Sendi, Parham
    Wustmann, Keratin
    Buechi, Annina E.
    Noti, Fabian
    Klaeser, Bernd
    Sonderegger, Beat
    der Maur, Christoph Auf
    Mercier, Thomas
    Schwerzmann, Markus
    Ruppen, Corinne
    [J]. OPEN FORUM INFECTIOUS DISEASES, 2019, 6 (04):
  • [2] Cardiac Implantable Electronic Device-Related Infection and Extraction Trends in the US
    Sridhar, Arun Raghav Mahankali
    Lavu, Madhav
    Yarlagadda, Vivek
    Reddy, Madhu
    Gunda, Sampath
    Afzal, Rizwan
    Atkins, Donita
    Gopinathanair, Rakesh
    Dawn, Buddhadeb
    Lakkireddy, Dhanunjaya R.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (03): : 286 - 293
  • [3] IMPLANTABLE DEVICE-RELATED INFECTION
    VanEpps, J. Scott
    Younger, John G.
    [J]. SHOCK, 2016, 46 (06): : 597 - 608
  • [4] Clinical Profile and Outcome of Patients with Cardiac Implantable Electronic Device-Related Infection
    Maciel, Alessandra de Souza
    Ferreira Lisboa da Silva, Rose Mary
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2021, 116 (06) : 1080 - 1088
  • [5] New guidelines for prevention and management of implantable cardiac electronic device-related infection
    Sandoe, Jonathan A. T.
    Barlow, Gavin
    Chambers, John B.
    Gammage, Michael
    Guleri, Achyut
    Howard, Philip
    Olson, Ewan
    Perry, John D.
    Prendergast, Bernard D.
    Spry, Michael J.
    Steeds, Richard P.
    Tayebjee, Muzahir H.
    Watkin, Richard
    [J]. LANCET, 2015, 385 (9984): : 2225 - 2226
  • [6] Bundled preparation of skin antisepsis decreases the risk of cardiac implantable electronic device-related infection
    Chen, Huang-Chung
    Chen, Mien-Cheng
    Chen, Yung-Lung
    Tsai, Tzu-Hsien
    Pan, Kuo-Li
    Lin, Yu-Sheng
    [J]. EUROPACE, 2016, 18 (06): : 858 - 867
  • [7] Review of cardiac implantable electronic device related infection
    Saliba, Emile
    Massie, Emmanuelle
    Sia, Ying Tung
    [J]. RESEARCH REPORTS IN CLINICAL CARDIOLOGY, 2016, 7 : 137 - 146
  • [8] Imaging of Cardiac Device-Related Infection
    Aguilera, Jose
    Hutt, Erika
    Jaber, Wael A.
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [9] Cardiac implantable electronic device infection
    Lambert, Cameron T.
    Tarakji, Khaldoun G.
    [J]. CLEVELAND CLINIC JOURNAL OF MEDICINE, 2017, 84 : 47 - 53
  • [10] High-Dose Daptomycin for Cardiac Implantable Electronic Device-Related Infective Endocarditis
    Durante-Mangoni, Emanuele
    Casillo, Roberta
    Bernardo, Mariano
    Caianiello, Cristina
    Mattucci, Irene
    Pinto, Daniela
    Agrusta, Federica
    Caprioli, Roberta
    Albisinni, Rosina
    Ragone, Enrico
    Utili, Riccardo
    [J]. CLINICAL INFECTIOUS DISEASES, 2012, 54 (03) : 347 - 354