Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals

被引:2
|
作者
Uccelli, Licia [1 ,2 ]
Boschi, Alessandra [1 ]
Martini, Petra [3 ,4 ]
Cittanti, Corrado [1 ,2 ]
Bertelli, Stefania [2 ]
Bortolotti, Doretta [2 ]
Govoni, Elena [2 ]
Lodi, Luca [2 ]
Romani, Simona [2 ]
Zaccaria, Samanta [2 ]
Zappaterra, Elisa [2 ]
Farina, Donatella [2 ]
Rizzo, Carlotta [1 ]
Giganti, Melchiore [1 ]
Bartolomei, Mirco [2 ]
机构
[1] Univ Ferrara, Morphol Surg & Expt Med Dept, Via L Borsari 46, I-44121 Ferrara, FE, Italy
[2] Univ Hosp, Nucl Med Unit, Via Aldo Moro 8, I-44124 Ferrara, FE, Italy
[3] Univ Ferrara, Phys & Heart Sci Dept, Via Giuseppe Saragat 1, I-44122 Ferrara, FE, Italy
[4] Italian Natl Inst Nucl Phys LNL INFN, Legnaro Natl Labs, Viale Univ 2, I-35020 Legnaro, PD, Italy
来源
MOLECULES | 2018年 / 23卷 / 03期
关键词
Tc-; 99m-radiopharmaceuticals; radiochemical purity; radiopharmaceuticals quality control;
D O I
10.3390/molecules23030661
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The influence of effective room temperature on the radiochemical purity of Tc-99m-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the Tc-99m-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the work area, the presence of instruments for heating, the continuous activation of air filtration, in addition to the fact that the environment of the isolator used for the Tc-99m-radiopharmaceuticals preparation and storage is completely isolated and not conditioned. A total of 244 Tc-99m-radiopharmaceutical preparations (seven different types) have been tested and the radiochemical purity was checked at the end of preparation and until the expiry time. Moreover, we found that the mean temperature into the isolator was significantly higher than 25 degrees C, the temperature, in general, required for the preparation and storage of( 99m) Tc-radiopharmaceuticals. Results confirmed the radiochemical stability of radiopharmaceutical products. However, as required in the field of quality assurance, the impact that different conditions than those required by the manufacturer on the radiopharmaceuticals quality have to be verified before human administration.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Evaluation of different counting methods for use in radiochemical purity testing procedures for 99mTc-labelled radiopharmaceuticals
    Maloli, Claudio
    Bestetti, Alberto
    Milani, Franco
    Cornalba, Gian Paolo
    Tagliabue, Luca
    Di Benedetto, Domenica
    Rognoni, Ilaria
    Tarolo, Gian Luigi
    Paroni, Rita
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (04) : 556 - 559
  • [22] Influence of temperature on the radiochemical purity of 99mTc-colloidal rhenium sulfide for use in sentinel node localization
    Bensimhon, Lyza
    Metaye, Thierry
    Guilhot, Joelle
    Perdrisot, Remy
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (11) : 1015 - 1020
  • [23] Can the way of 99mTc-radiopharmaceuticals withdrawal from the vials affect their quality for administration?
    Komarek, P.
    Komarkova, I.
    Polivkova, L.
    Staskova, J.
    Kupcova, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S259 - S260
  • [24] Optimizing the Assessment of [99mTc]-SestaMIBI Radiochemical Purity: A Study on Stability in Syringe Storage
    Hashemizadeh, Haleh
    Hassanzadeh, Leila
    Azizian, Homa
    Paydar, Reza
    Ahmadvand, Davoud
    IRANIAN HEART JOURNAL, 2025, 26 (01): : 67 - 80
  • [25] HPLC investigation of the radiochemical purity of 99mTc-MIBI
    Tasdelen, Betul
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 290 (02) : 283 - 287
  • [26] A RAPID METHOD OF RADIOCHEMICAL PURITY FOR TC-99M RADIOPHARMACEUTICALS
    COHEN, YIC
    BESNARD, MR
    JOURNAL OF NUCLEAR MEDICINE, 1981, 22 (06) : P74 - P74
  • [27] Radiochemical purity of 99mTc radio-pharmaceuticals
    Vucina, J. L.
    Vuga, D. A.
    Vukicevic-Nikolic, N. S.
    Journal of Radioanalytical and Nuclear Chemistry, 1995, 199 (02)
  • [28] HPLC investigation of the radiochemical purity of 99mTc-MIBI
    Betül Taşdelen
    Journal of Radioanalytical and Nuclear Chemistry, 2011, 290 : 283 - 287
  • [29] Radiochemical purity and stability of generic 99mTc Tetrofosmin
    Albarnawi, Emam
    Zimmer, Mike
    Voll, Bruce
    Riehle, Lisa
    Spies, Stewart
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [30] Test of Radiochemical Purity in 99mTc-labeled Pharmaceuticals
    Mathiasen, S. K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S453 - S453