Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals

被引:2
|
作者
Uccelli, Licia [1 ,2 ]
Boschi, Alessandra [1 ]
Martini, Petra [3 ,4 ]
Cittanti, Corrado [1 ,2 ]
Bertelli, Stefania [2 ]
Bortolotti, Doretta [2 ]
Govoni, Elena [2 ]
Lodi, Luca [2 ]
Romani, Simona [2 ]
Zaccaria, Samanta [2 ]
Zappaterra, Elisa [2 ]
Farina, Donatella [2 ]
Rizzo, Carlotta [1 ]
Giganti, Melchiore [1 ]
Bartolomei, Mirco [2 ]
机构
[1] Univ Ferrara, Morphol Surg & Expt Med Dept, Via L Borsari 46, I-44121 Ferrara, FE, Italy
[2] Univ Hosp, Nucl Med Unit, Via Aldo Moro 8, I-44124 Ferrara, FE, Italy
[3] Univ Ferrara, Phys & Heart Sci Dept, Via Giuseppe Saragat 1, I-44122 Ferrara, FE, Italy
[4] Italian Natl Inst Nucl Phys LNL INFN, Legnaro Natl Labs, Viale Univ 2, I-35020 Legnaro, PD, Italy
来源
MOLECULES | 2018年 / 23卷 / 03期
关键词
Tc-; 99m-radiopharmaceuticals; radiochemical purity; radiopharmaceuticals quality control;
D O I
10.3390/molecules23030661
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The influence of effective room temperature on the radiochemical purity of Tc-99m-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the Tc-99m-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the work area, the presence of instruments for heating, the continuous activation of air filtration, in addition to the fact that the environment of the isolator used for the Tc-99m-radiopharmaceuticals preparation and storage is completely isolated and not conditioned. A total of 244 Tc-99m-radiopharmaceutical preparations (seven different types) have been tested and the radiochemical purity was checked at the end of preparation and until the expiry time. Moreover, we found that the mean temperature into the isolator was significantly higher than 25 degrees C, the temperature, in general, required for the preparation and storage of( 99m) Tc-radiopharmaceuticals. Results confirmed the radiochemical stability of radiopharmaceutical products. However, as required in the field of quality assurance, the impact that different conditions than those required by the manufacturer on the radiopharmaceuticals quality have to be verified before human administration.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Single UHPLC-SEC method for the determination of radiochemical purity of 99mTc-radiopharmaceuticals
    Fouque, J.
    Gerard, C.
    Huguet, S.
    Branquinho, E. Da Costa
    Gomes, S. Blondeel
    Rezai, K.
    Madar, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S668 - S669
  • [2] Practices in radiopharmacy: Is the use of a breathing needle a concern on the radiochemical purity of 99mTc-radiopharmaceuticals?
    Oliveira, M.
    Oliveira, T.
    Rebelo, A.
    Sousa, C.
    Silva, A.
    Nery, J.
    Amorim, I.
    Castro, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S517 - S517
  • [3] CELLULOSE-ACETATE ELECTROPHORESIS AS A TECHNIQUE FOR THE RADIOCHEMICAL ANALYSIS OF 99MTC-RADIOPHARMACEUTICALS
    BELLEN, JC
    CAMPBELL, J
    BAKER, RJ
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1984, 14 (06): : 945 - 946
  • [4] Effect of 99Tc on the radiochemical purity of 99mTc radiopharmaceuticals
    Waight, Lynn A.
    Cunnane, Caroline M.
    O'Brien, Lesley M.
    Millar, Alistair M.
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (08) : 752 - 756
  • [5] Current Approach in Radiochemical Quality Control of the 99mTc-Radiopharmaceuticals: a mini-review
    Camargo Miranda, Ana Claudia
    Ranucci Durante, Ana Claudia
    Fuscaldi, Leonardo Lima
    de Barboza, Marycel Figols
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2019, 62 : 1 - 7
  • [6] Radical scavengers and the stability of 99mTc-radiopharmaceuticals
    Berger, R.
    1600, (33):
  • [7] Influence of the Generator in-Growth Time on the Final Radiochemical Purity and Stability of 99mTc Radiopharmaceuticals
    Uccelli, L.
    Boschi, A.
    Pasquali, M.
    Duatti, A.
    Di Domenico, G.
    Pupillo, G.
    Esposito, J.
    Giganti, M.
    Taibi, A.
    Gambaccini, M.
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2013, 2013
  • [8] Radiochemical purity testing of 99mTc-labelled radiopharmaceuticals: how much is enough?
    Ballinger, James R.
    Blower, Philip J.
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (09) : 761 - 763
  • [9] Study of the influence of the first elution from generators 99Mo/99mTc in the radiochemical purity of radiopharmaceuticals preparations
    Diaz Alarcon, J. P.
    Palacios Gerona, H.
    Urena Lara, M. J.
    Cepedello Boiso, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S415 - S415
  • [10] Influence of humidity on radiochemical purity of 99mTc-ECD and 99mTc-Sestamibi
    dos Santos, Elaine Vasconcelos
    de Oliveira, Mercia Liane
    do Nascimento, Joao Eudes
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 306 (03) : 751 - 755