Bolus timing in high-pitch CT angiography of the aorta

被引:13
|
作者
Beeres, Martin [1 ]
Loch, Matthias [1 ]
Schulz, Boris [1 ]
Kerl, Matthias [1 ]
Al-Butmeh, Firas [1 ]
Bodelle, Boris [1 ]
Herrmann, Eva [2 ]
Gruber-Rouh, Tatjana [1 ]
Lee, Clara [1 ]
Jacobi, Volkmar [1 ]
Vogl, Thomas J. [1 ]
Bauer, Ralf W. [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Clin Goethe Univ, Dept Biostat, D-60590 Frankfurt, Germany
关键词
CT angiography; Aorta; High-pitch CT; Dual-source CT; Bolus geometry; IMAGE QUALITY; INJECTION; PROTOCOLS;
D O I
10.1016/j.ejrad.2013.01.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1028 / 1033
页数:6
相关论文
共 50 条
  • [21] Contrast medium application in pediatric high-pitch cardiovascular CT angiography: Manual or power injection?
    Saake, Marc
    Lell, Michael M.
    Rompel, Oliver
    Gloeckler, Martin
    May, Matthias
    Eller, Achim
    Achenbach, Stephan
    Uder, Michael
    Wuest, Wolfgang
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (04) : 315 - 322
  • [22] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Lembcke, Alexander
    Schwenke, Carsten
    Hein, Patrick A.
    Knobloch, Gesine
    Durmus, Tahir
    Hamm, Bernd
    Huppertz, Alexander
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (01) : 120 - 127
  • [23] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Gordic, Sonja
    Husarik, Daniela B.
    Desbiolles, Lotus
    Leschka, Sebastian
    Frauenfelder, Thomas
    Alkadhi, Hatem
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (06): : 1173 - 1179
  • [24] High-pitch Dual-source CT Angiography before TAVI - the Value of ECG Gating
    Bucher, Andreas Michael
    Albrecht, Moritz Hans
    Scholtz, Jan Erik
    Herrmann, Eva
    Kaup, Moritz
    Gruber-Rouh, Tatjana
    Jacobi, Volkmar
    Vogl, Thomas Josef
    Beeres, Martin
    [J]. CURRENT MEDICAL IMAGING REVIEWS, 2019, 15 (04) : 373 - 379
  • [25] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Sonja Gordic
    Daniela B. Husarik
    Lotus Desbiolles
    Sebastian Leschka
    Thomas Frauenfelder
    Hatem Alkadhi
    [J]. The International Journal of Cardiovascular Imaging, 2014, 30 : 1173 - 1179
  • [26] Systolic High-Pitch Coronary CT Angiography for Evaluation of the Coronary Arteries in Heart Transplant Recipients
    Bastarrika, Gorka
    Calvo, Marta
    Ezponda, Ana
    Garcia-Baizan, Alejandra
    Caballeros, Meylin
    Rabago, Gregorio
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (04) : 828 - 833
  • [27] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Alexander Lembcke
    Carsten Schwenke
    Patrick A. Hein
    Gesine Knobloch
    Tahir Durmus
    Bernd Hamm
    Alexander Huppertz
    [J]. European Radiology, 2014, 24 : 120 - 127
  • [28] Highly accelerated, Dixon-based non-contrast MR angiography versus high-pitch CT angiography
    Zeilinger, Martin Georg
    Giese, Daniel
    Schmidt, Michaela
    May, Matthias Stefan
    Janka, Rolf
    Heiss, Rafael
    Ammon, Fabian
    Achenbach, Stephan
    Uder, Michael
    Treutlein, Christoph
    [J]. RADIOLOGIA MEDICA, 2024, 129 (02): : 268 - 279
  • [29] Non-ECG-gated high-pitch CT angiography versus hybrid ECG-gated CT angiography for aorta using 512-slice CT: comparison of image quality and radiation dose
    Lee, Jimin
    Jeong, Yeon Joo
    Lee, Geewon
    Kim, Chang Won
    Kim, Jin You
    Lee, Nam Kyung
    Lee, Han Cheol
    Lee, Ji Won
    [J]. ACTA RADIOLOGICA, 2023, 64 (02) : 515 - 523
  • [30] Highly accelerated, Dixon-based non-contrast MR angiography versus high-pitch CT angiography
    Martin Georg Zeilinger
    Daniel Giese
    Michaela Schmidt
    Matthias Stefan May
    Rolf Janka
    Rafael Heiss
    Fabian Ammon
    Stephan Achenbach
    Michael Uder
    Christoph Treutlein
    [J]. La radiologia medica, 2024, 129 : 268 - 279