A high-resolution gas-source isotope ratio mass spectrometer

被引:76
|
作者
Eiler, John M. [1 ]
Clog, Matthieu [1 ]
Magyar, Paul [1 ]
Piasecki, Alison [1 ]
Sessions, Alex [1 ]
Stolper, Daniel [1 ]
Deerberg, Michael
Schlueter, Hans-Juergen
Schwieters, Johannes
机构
[1] CALTECH, Div Geol & Planetary Sci, Pasadena, CA 91125 USA
基金
美国国家科学基金会;
关键词
Stable isotope; Geochemistry; Hydrocarbon; STABLE-ISOTOPES; OXYGEN; CARBON; ARGON;
D O I
10.1016/j.ijms.2012.10.014
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
We describe a new high-resolution, multi-collector gas source mass spectrometer designed for isotopic analysis of volatile and semi-volatile molecules: the Thermo Scientific MAT253-Ultra, a prototype double-focusing isotope ratio mass spectrometer installed in the Caltech laboratories for stable isotope geochemistry. This instrument achieves mass resolving power of up to similar to 27,000 (M/Delta M) and can analyze diverse gases and semi-volatile compounds using a conventional dual inlet and/or a carrier gas. It has a multi-collector array comprised of 7 detector positions with adjustable spacing, all of which can register ions through an SEM or Faraday cup and spanning up to a 10(13) range in signal strength. Abundance sensitivity in the He mass range is as good as 10(-12), and precision commonly approaches the counting statistics limit down to 0.1 parts per thousand (SEM) or 0.01 parts per thousand (Faraday) for a range of analytes. This instrument permits resolution of isobaric interferences arising from both contaminants and multiple isotopologues of an analyte that share a cardinal mass, enabling direct isotopic analysis of molecules with complex mass spectra such as hydrocarbons. This ability should enable the measurement of position-specific isotopic compositions, including multiple substitutions, by comparing isotope ratios of molecular ions with those of daughter fragment ions (assuming products of recombination and other source reactions are recognized and corrected for). The combination of high mass resolution with stable multicollection will provide a wide range of potential new tools for isotope geochemistry, including (but not limited to): singly and multiply substituted methane and larger hydrocarbons; position-specific C-13 analysis of propane and larger hydrocarbons; precise analysis of O-17/O-16 and O-18/O-16 on fragment ions from CO2 and other molecules; analysis of a variety of N2O isotopologues (including O-18,O-17, position-specific N-15, and various 'clumped' species); and high precision and abundance sensitivity noble gas analyses. These capabilities greatly extend the scope of stable isotope variations that can be utilized for problems in forensics, environmental geochemistry, biochemistry, and Earth and planetary sciences. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 56
页数:12
相关论文
共 50 条
  • [21] Stable Nitrogen Isotope Analysis of Amino Acids by Gas Chromatography-Combustion-Isotope Ratio Mass Spectrometry for High-Resolution Trophic Level Estimation
    Zhao Jing-Jing
    Zhang Zhong-Yi
    Zheng Neng-Jian
    Tian Jing
    Zhu Guang-Xu
    Xiao Hua-Yun
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (03) : 309 - 315
  • [22] The use of a high-resolution quadrupole gas mass spectrometer system for selective detection of helium and deuterium
    Day, C
    [J]. VACUUM, 1998, 51 (01) : 21 - 30
  • [23] A new gas inlet system for an isotope ratio mass spectrometer improves reproducibility
    Leuenberger, M
    Nyfeler, P
    Moret, HP
    Sturm, P
    Huber, C
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (16) : 1543 - 1551
  • [24] Isotope dilution high-resolution gas chromatography/high-resolution mass spectrometry method for analysis of selected acidic herbicides in surface water
    Woudneh, Million B.
    Sekela, Mark
    Tuominen, Taina
    Gledhill, Melissa
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1133 (1-2) : 293 - 299
  • [25] Determination of atmospheric organochlorine pesticides using isotope dilution high resolution gas chromatography/high-resolution mass spectrometry
    Zhang Jingxing
    Zheng Xiaoyan
    Li, Tan
    Liu Jinbin
    Yu Haibin
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (05) : 541 - 551
  • [26] DESIGN OF A HIGH-RESOLUTION MASS SPECTROMETER FOR STUDYING THE PHOTODISSOCIATION OF ORGANIC IONS IN THE GAS PHASE.
    Harris, F.M.
    Mukhtar, E.S.
    Griffiths, I.W.
    Beynon, J.H.
    [J]. Proceedings of The Royal Society of London, Series A: Mathematical and Physical Sciences, 1981, 374 (1759) : 461 - 473
  • [27] Use of a high-resolution quadrupole gas mass spectrometer system for selective detection of helium and deuterium
    Forschungszentrum Karlsruhe, Karlsruhe, Germany
    [J]. Vacuum, 1 (21-30):
  • [28] A modified procedure for gas-source isotope ratio mass spectrometry: the long-integration dual-inlet (LIDI) methodology and implications for clumped isotope measurements
    Hu, Bin
    Radke, Jens
    Schlueter, Hans-Juergen
    Heine, Frank Torsten
    Zhou, Liping
    Bernasconi, Stefano M.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (13) : 1413 - 1425
  • [29] A MASS SPECTROMETER FOR ISOTOPE AND GAS ANALYSIS
    NIER, AO
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1947, 18 (06): : 398 - 411
  • [30] Background effects on Faraday collectors in gas-source mass spectrometry and implications for clumped isotope measurements
    Bernasconi, Stefano M.
    Hu, Bin
    Wacker, Ulrike
    Fiebig, Jens
    Breitenbach, Sebastian F. M.
    Rutz, Tanja
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (05) : 603 - 612