Clinical significance of the mixing test in laboratory diagnoses of lupus anticoagulant: the fate of the mixing test in integrated lupus anticoagulant test systems

被引:15
|
作者
Hong, Sung Kuk [1 ]
Hwang, Sang Mee [1 ]
Kim, Ji-Eun [2 ]
Kim, Hyun Kyung [1 ,2 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Lab Med, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Canc Res, Seoul 110744, South Korea
基金
新加坡国家研究基金会;
关键词
lupus anticoagulant; mixing test; thrombosis; ANTIPHOSPHOLIPID SYNDROME; GUIDELINES; CRITERIA; UPDATE;
D O I
10.1097/MBC.0b013e328358e899
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The mixing test is used to determine the presence of inhibitors in laboratory diagnoses of lupus anticoagulant. Updated international guidelines state that an integrated lupus anticoagulant test system does not require the mixing test; an appraisal of the mixing tests in integrated lupus anticoagulant test systems is, therefore, required. We investigated the clinical relevance of mixing tests by using the best cutoff value of the mixing test through thrombotic risk analysis. A retrospective analysis was performed on 525 specimens with positive screening tests by using two integrated lupus anticoagulant tests: diluted Russell's Viper venom (dRVVT) and silica clotting time. The diagnostic performance of two interpretation formulas (percentage correction, Rosner index) was assessed, and the thrombotic risk of a subgroup based on the mixing results was investigated. Finally, the thrombotic risk of lupus anticoagulant positivity based on the integrated lupus anticoagulant test system procedures was assessed for the appraisal of mixing test exclusion in integrated lupus anticoagulant test systems. The best cutoff values of mixing test interpretation methods based on dRVVT were as follows: 60.1% for percentage correction and 15.7 for Rosner index. There was no substantial difference in the thrombotic risk between percentage correction and the Rosner index. The mixing-positive group showed a higher lupus anticoagulant titer and higher thrombotic risk than the mixing-negative group. However, even the mixing-negative group carried a significant risk of thrombosis. Finally, lupus anticoagulant positivity determined by the updated two-step procedure (screening and confirmation tests) showed higher thrombotic risk than that determined by the traditional three-step procedure (screening, mixing, and confirmation tests). Although a positive mixing result can predict a high risk of thrombosis, negative mixing results are also associated with a substantial thrombotic risk. The updated two-step procedure without the mixing test is relevant for lupus anticoagulant detection in the context of thrombotic risk estimation. Blood Coagul Fibrinolysis 23: 739-744 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:739 / 744
页数:6
相关论文
共 50 条
  • [21] THE LUPUS ANTICOAGULANT - CLINICAL AND LABORATORY ASSOCIATIONS
    COLACO, CB
    ELKON, KB
    GHARAVI, AE
    HUGHES, GRV
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1983, 42 (02) : 228 - 228
  • [22] Performance characteristics of 5 numerical indexes in mixing test interpretation under coexistence of lupus anticoagulant and coagulation factor deficiency
    Matsuda, Masato
    Hoshiyama, Yoshiki
    Ogawa, Kazuei
    Emmi, Mari
    Terai, Shuji
    Moriyama, Masato
    [J]. RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2023, 7 (02)
  • [23] A SENSITIVE APTT TEST AS A PREDICTOR OF A NEGATIVE LUPUS ANTICOAGULANT (LAC)
    Schuijt, T. J.
    de Groot, M.
    Westerink, J.
    Limper, M.
    Urbanus, R.
    Huisman, A.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 129 - 129
  • [24] SENSITIVE TEST DEMONSTRATING LUPUS ANTICOAGULANT AND ITS BEHAVIORAL PATTERNS
    EXNER, T
    RICKARD, KA
    KRONENBERG, H
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1978, 40 (01) : 143 - 151
  • [25] SOYBEAN PHOSPHOLIPIDS APTT AS A CONFIRMATORY TEST FOR THE DETECTION OF LUPUS ANTICOAGULANT
    BRANCACCIO, V
    CIAMPA, A
    ADNREA, D
    IANNACCONE, L
    CIMINO, R
    [J]. THROMBOSIS RESEARCH, 1993, 70 : S125 - S125
  • [26] Mixing test specific cut-off is more sensitive at detecting lupus anticoagulants than index of circulating anticoagulant
    Moore, Gary W.
    Culhane, Aidan P.
    Daw, Christopher R.
    Noronha, Charlotte P.
    Kumano, Osamu
    [J]. THROMBOSIS RESEARCH, 2016, 139 : 98 - 101
  • [27] THROMBIN-THROMBOMODULIN INHIBITION TEST IN PATIENTS WITH LUPUS ANTICOAGULANT
    UCHMAN, BI
    TRIPLETT, DA
    PARKINSON, JF
    BANG, NU
    [J]. THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 673 - 673
  • [28] AN EVALUATION OF 2 COMMERCIAL TEST PROCEDURES FOR THE DETECTION OF LUPUS ANTICOAGULANT
    SCHJETLEIN, R
    WISLOFF, F
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 103 (01) : 108 - 111
  • [29] A STUDY OF THE INTERRELATIONSHIP OF THE ANTICARDIOLIPIN ANTIBODY-TEST TO THE LUPUS ANTICOAGULANT
    SAHUD, MA
    PALKUTI, H
    [J]. THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 1259 - 1259
  • [30] A new lupus anticoagulant test based on dilute prothrombin time
    Mackie, IJ
    Lawrie, AS
    Greenfield, RS
    Guinto, ER
    Machin, SJ
    [J]. THROMBOSIS RESEARCH, 2004, 114 (5-6) : 673 - 674