Surface-alkylated polystyrene monolithic columns for peptide analysis in capillary liquid chromatography-electrospray ionization mass spectrometry

被引:88
|
作者
Huang, XA [1 ]
Zhang, S [1 ]
Schultz, GA [1 ]
Henion, J [1 ]
机构
[1] Advion Biosci Inc, Ithaca, NY 14850 USA
关键词
D O I
10.1021/ac011202w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Macroporous poly(styrene-divinylbenzene) (PS-DVB) monoliths were prepared by in situ polymerization in PEEK, fused silica, or stainless steel tubing having an inner diameter of 75 or 125 mum. A process is described for subsequent alkylation of the flow-contacting surfaces of the monoliths. The process treats all the surfaces including through-pore surfaces of the rigid macroporous monolith with a solution containing a dissolved Friedel-Crafts catalyst, an alkyl halide (1-chloroocyadecane), and an organic solvent. This process produces an improved reversed-phase liquid chromatographic separation of peptides compared to an unmodified monolithic PS-DVB column. The surface octadecylation is not necessary for a reversed-phase separation of proteins since both unmodified and modified columns provide comparable results. Tryptic protein digests, standard proteins, and standard peptides were used to evaluate the monolithic columns by employing electrospray mass spectrometry detection. Potential applications in proteomics studies by mass spectrometry, which use the alkylated monolithic column engaged onto the nanofabricated electrospray ionization chip, are also discussed.
引用
收藏
页码:2336 / 2344
页数:9
相关论文
共 50 条
  • [1] Monolithic capillary columns for liquid chromatography-electrospray ionization mass spectrometry in proteomic and genomic research
    Walcher, W
    Oberacher, H
    Troiani, S
    Hölzl, G
    Oefner, P
    Zolla, L
    Huber, CG
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 782 (1-2): : 111 - 125
  • [2] Polystyrene/divinylbenzene based monolithic and encapsulated capillary columns for the analysis of nucleic acids by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Huck, CW
    Bakry, R
    Bonn, GK
    [J]. ENGINEERING IN LIFE SCIENCES, 2005, 5 (05): : 431 - 435
  • [3] Capillary high-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic columns and carbon fiber electrospray ionization emitters
    Ro, KW
    Liu, H
    Busman, M
    Knapp, DR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1047 (01) : 49 - 57
  • [4] High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies
    Premstaller, A
    Oberacher, H
    Walcher, W
    Timperio, AM
    Zolla, L
    Chervet, JP
    Cavusoglu, N
    van Dorsselaer, A
    Huber, CG
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (11) : 2390 - +
  • [5] Optimization and Evaluation of a Sheathless Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry Platform for Peptide Analysis: Comparison to Liquid Chromatography-Electrospray Ionization Mass Spectrometry
    Faserl, Klaus
    Sarg, Bettina
    Kremser, Leopold
    Lindner, Herbert
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (19) : 7297 - 7305
  • [6] Analysis of corticosteroids in hair by Liquid chromatography-electrospray ionization mass spectrometry
    Bévalot, F
    Gaillard, Y
    Lhermitte, MA
    Pépin, G
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02): : 227 - 236
  • [7] Evaluation of capillary liquid chromatography-electrospray ionization ion mobility spectrometry with mass spectrometry detection
    Matz, LM
    Dion, HM
    Hill, HH
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) : 59 - 68
  • [8] Quantification of cardiolipin by liquid chromatography-electrospray ionization mass spectrometry
    Garrett, Teresa A.
    Kordestani, Reza
    Raetz, Christian R. H.
    [J]. LIPIDOMICS AND BIOACTIVE LIPIDS: SPECIALIZED ANALYTICAL METHODS AND LIPIDS IN DISEASE, 2007, 433 : 213 - 230
  • [9] High-performance liquid chromatography-electrospray ionization mass spectrometry of single- and double-stranded nucleic acids using monolithic capillary columns
    Premstaller, A
    Oberacher, H
    Huber, CG
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (18) : 4386 - 4393
  • [10] Capillary monoliths for the analysis of nucleic acids by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Oberacher, H
    Huber, CG
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (03) : 166 - 174