Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments

被引:486
|
作者
McEwen, CN [1 ]
McKay, RG [1 ]
Larsen, BS [1 ]
机构
[1] DuPont Corp Ctr Analyt Sci, Wilmington, DE 19880 USA
关键词
D O I
10.1021/ac051470k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct analysis of samples using atmospheric pressure ionization (API) provides a more rapid method for analysis of volatile and semivolatile compounds than vacuum solids probe methods and can be accomplished on commercial API mass spectrometers. With only a simple modification to either an electrospray (ESI) or atmospheric pressure chemical ionization (APCI) source, solid as well as liquid samples can be analyzed in seconds. The method acts as a fast solids/liquid probe introduction as well as an alternative to the new direct analysis in real time (DART) and desorption electrospray ionization (DESI) methods for many compound types. Vaporization of materials occurs in the hot nitrogen gas stream flowing from an ESI or APCI probe. Ionization of the thermally induced vapors occurs by corona discharge under standard APCI conditions. Accurate mass and mass-selected fragmentation are demonstrated as is the ability to obtain ions from biological tissue, currency, and other objects placed in the path of the hot nitrogen stream.
引用
收藏
页码:7826 / 7831
页数:6
相关论文
共 49 条
  • [31] Rapid and accurate detection of cinnamon oil adulteration in perilla leaf oil using atmospheric solids analysis probe-mass spectrometry
    Wu, Yanpei
    Huang, Lieyan
    Xu, Yan
    Zhang, Yi
    Nie, Lixing
    Kang, Shuai
    Wei, Feng
    Ma, Shuangcheng
    FOOD CHEMISTRY, 2025, 462
  • [32] Rapid determination of the skin irritant p-phenylenediamine (PPD) in henna products using atmospheric solids analysis probe mass spectrometry
    Chen, W.
    Nkosi, T. A. N.
    Combrinck, S.
    Viljoen, A. M.
    Cartwright-Jones, C.
    PLANTA MEDICA, 2016, 82
  • [33] Atmospheric Solids Analysis Probe (ASAP) and Atmospheric Pressure Gas Chromatography (APGC) coupled to Quadrupole Time of Flight Mass Spectrometry (QTOF-MS) as alternative techniques to trace aromatic markers of mineral oils in food packaging
    Jaen, Janira
    Domeno, Celia
    Alfaro, Pilar
    Nerin, Cristina
    TALANTA, 2021, 227
  • [34] Rapid methods of polymer and polymer additives identification: Multi-sample solvent-free MALDI, pyrolysis at atmospheric pressure, and atmospheric solids analysis probe mass spectrometry
    Trimpin, Sarah
    Wijerathne, Kanchana
    McEwen, Charles N.
    ANALYTICA CHIMICA ACTA, 2009, 654 (01) : 20 - 25
  • [35] Volumetric Absorptive Microsampling (VAMS) for assaying immunosuppressants from venous whole blood by LC-MS/MS using a novel atmospheric pressure ionization probe (UniSpray™)
    Paniagua-Gonzalez, Lucia
    Diaz-Louzao, Carla
    Lendoiro, Elena
    Otero-Anton, Esteban
    Cadarso-Suarez, Carmen
    Lopez-Rivadulla, Manuel
    Cruz, Angelines
    de-Castro-Rios, Ana
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 189
  • [36] Rapid characterization of heteroatomic molecules in a bio-oil from pyrolysis of rice husk using atmospheric solids analysis probe mass spectrometry
    Fan, Xing
    Zhu, Ji-Liang
    Zheng, Ai-Li
    Wei, Xian-Yong
    Zhao, Yun-Peng
    Cao, Jing-Pei
    Zhao, Wei
    Lu, Yao
    Chen, Lu
    You, Chun-Yan
    Journal of Analytical and Applied Pyrolysis, 2015, 115 : 16 - 23
  • [37] Rapid characterization of heteroatomic molecules in a bio-oil from pyrolysis of rice husk using atmospheric solids analysis probe mass spectrometry
    Fan, Xing
    Zhu, Ji-Liang
    Zheng, Ai-Li
    Wei, Xian-Yong
    Zhao, Yun-Peng
    Cao, Jing-Pei
    Zhao, Wei
    Lu, Yao
    Chen, Lu
    You, Chun-Yan
    JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2015, 115 : 16 - 23
  • [38] Quantitative analysis of adenosine using liquid chromatography/atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS)
    Van Dycke, Annelies
    Verstraete, Alain
    Pil, Kristof
    Raedt, Robrecht
    Vonck, Kristl
    Boison, Detlev
    Boon, Paul
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1493 - 1498
  • [39] An atmospheric pressure ionization source using a high voltage target compared to electrospray ionization for the LC/MS analysis of pharmaceutical compounds
    Lubin, Arnaud
    De Vries, Ronald
    Cabooter, Deirdre
    Augustijns, Patrick
    Cuyckens, Filip
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 142 : 225 - 231
  • [40] Direct and Fast Screening of New Psychoactive Substances Using Medical Swabs and Atmospheric Solids Analysis Probe Triple Quadrupole with Data-Dependent Acquisition
    Fabregat-Safont, David
    Felis-Brittes, Daniela
    Mata-Pesquera, Maria
    Sancho, Juan, V
    Hernandez, Felix
    Ibanez, Maria
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (07) : 1610 - 1614