Routine ultrasound screening in diabetic pregnancies

被引:27
|
作者
Wong, SF [1 ]
Chan, FY [1 ]
Cincotta, RB [1 ]
Oats, JJN [1 ]
McIntyre, HD [1 ]
机构
[1] Mater Mothers Hosp, Dept Maternal Fetal Med, Brisbane, Qld 4101, Australia
关键词
diabetic pregnancies; routine ultrasound screening;
D O I
10.1046/j.0960-7692.2001.00560.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To assess the detection rate of congenital fetal malformations and specific problems related to routine ultrasound screening in women with pre-existing diabetes. Methods A retrospective study was carried out to assess the performance of routine ultrasound screening in women with pre-existing diabetes (Types 1 and 2) within a tertiary institution. The incidence, type and risk factors for congenital fetal malformations were determined. The detection rate of fetal anomalies for diabetic women was compared with that for the low-risk population. Factors affecting these detection rates were evaluated. Results During the study period, 12 169 low-risk pregnant women and 130 women with pre-existing diabetes had routine ultrasound screening performed within the institution. A total of 10 major anomalies (7.7%) and three minor anomalies (2.3%) were present in the fetuses of the diabetic women. Central nervous system and cardiovascular system anomalies accounted for 60% of the major anomalies. Peri-conceptional hemoglobin A 1 c of more than 9% was associated with a high prevalence of major anomalies (14311000). Women who had fetuses with major anomalies bad a significantly higher incidence of obesity (78% vs. 37%; P < 0.05). Ultrasound examination of these diabetic pregnancies showed high incidences of suboptimal image quality (37%), incomplete examinations, and repeat examinations (17%). Compared to the 'low-risk' non-diabetic population from the same institution, the relative risk for a major congenital anomaly among the diabetic women was 5.9-fold higher (95% confidence interval, 2.9-11.9). The detection rate for major fetal anomalies was significantly lower for diabetic women (30% vs. 73%; P < 0.01), and the mean body mass index for the diabetic group was significantly higher (29 vs. 23 kg/m(2); P < 0.001). Conclusion The incidence of congenital anomalies is higher in diabetic pregnancies. Unfortunately, the detection rate for fetal anomalies by antenatal ultrasound scan was significantly, worse than that for the low-risk population. This is likely to be related to the maternal body habitus and unsatisfactory examinations. Methods to overcome these difficulties are discussed.
引用
收藏
页码:171 / 176
页数:6
相关论文
共 50 条
  • [41] Routine antenatal thrombophilia screening in high-risk pregnancies - A decision analysis
    Chaudhury, Padmashree
    Sessions, Donna
    Gardner, Michael O.
    Doyle, Nora M.
    OBSTETRICS AND GYNECOLOGY, 2008, 111 (04): : 98S - 98S
  • [42] Routine Antenatal Thrombophilia Screening in High-Risk Pregnancies: A Decision Analysis
    Woodham, Padmashree Chaudhury
    Boggess, Kim A.
    Gardner, Michael O.
    Doyle, Nora M.
    AMERICAN JOURNAL OF PERINATOLOGY, 2011, 28 (06) : 495 - 499
  • [43] ULTRASOUND AND HUMAN PLACENTAL LACTOGEN SCREENING FOR EARLY DETECTION OF TWIN PREGNANCIES
    GRENNERT, L
    PERSSON, PH
    GENNSER, G
    KULLANDER, S
    LANCET, 1976, 1 (7949): : 4 - 6
  • [44] SCREENING FOR DIABETIC MICROALBUMINURIA IN ROUTINE CLINICAL CARE - WHICH METHOD
    SHIELD, JPH
    HUNT, LP
    BAUM, JD
    PENNOCK, CA
    ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 72 (06) : 524 - 525
  • [45] UTILIZING SIMULATION TO UPDATE ROUTINE DIABETIC RETINOPATHY SCREENING POLICIES
    Dorali, Poria
    Limongi, Rosangel
    Torsha, Fariha Kabir
    Weng, Christina Y.
    Lee, Taewoo
    2022 WINTER SIMULATION CONFERENCE (WSC), 2022, : 1128 - 1139
  • [46] Routine ultrasound screening in pregnancy and the children's subsequent handedness
    Kieler, H
    Axelsson, O
    Haglund, B
    Nilsson, S
    Salvesen, KA
    EARLY HUMAN DEVELOPMENT, 1998, 50 (02) : 233 - 245
  • [47] Routine ultrasound screening in pregnancy and the children's subsequent handedness
    Kieler, H
    Axelsson, O
    Haglund, B
    Nilsson, S
    Salvesen, KÅ
    Dev, EH
    JOURNAL OF ULTRASOUND IN MEDICINE, 2004, 23 (11) : 1538 - 1539
  • [48] Screening esophagus during routine ultrasound: medical and cost benefits
    Abd Elrazek, Abd Elrazek M. A.
    Eid, Khaled A.
    El-Sherif, Abd Elhalim A.
    Abd El Al, Usama M.
    El-Sherbiny, Samir M.
    Bilasy, Shymaa E.
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2015, 27 (01) : 8 - 12
  • [49] Routine second-trimester ultrasound for low risk pregnancies in a South African community
    van Dyk, B.
    Motto, J. A.
    Buchmann, E. J.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 98 (03) : 257 - 258
  • [50] Routine ultrasound screening of congenital anomalies - An overview of the European experience
    Levi, S
    ULTRASOUND SCREENING FOR FETAL ANOMALIES: IS IT WORTH IT?: SCREENING REVISITED AFTER THE EUROFETUS DATA, 1998, 847 : 86 - 98