Robust Analysis of High Throughput Screening (HTS) Assay Data

被引:13
|
作者
Lim, Changwon [1 ]
Sen, Pranab K. [2 ,3 ]
Peddada, Shyamal D. [4 ]
机构
[1] Loyola Univ, Dept Math & Stat, Chicago, IL 60660 USA
[2] Univ N Carolina, Dept Stat & Operat Res, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Biostat, Chapel Hill, NC 27599 USA
[4] NIEHS, NIH, Res Triangle Pk, NC 27709 USA
关键词
Dose-response study; False discovery rate (FDR); Heteroscedasticity; Hill model; M-estimation procedure; Nonlinear regression model; Power; Toxicology; FALSE DISCOVERY RATE;
D O I
10.1080/00401706.2012.749166
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Quantitative high throughput screening (qHTS) assays use cells or tissues to screen thousands of compounds in a short period of time. Data generated from qHTS assays are then evaluated using nonlinear regression models, such as the Hill model, and decisions regarding toxicity are made using the estimates of the parameters of the model. For any given compound, the variability in the observed response may either be constant across dose groups (homoscedasticity) or vary with dose (heteroscedasticity). Since thousands of compounds are simultaneously evaluated in a qHTS assay, it is not practically feasible for an investigator to perform residual analysis to determine the variance structure before performing statistical inferences on each compound. Since it is well known that the variance structure plays an important role in the analysis of linear and nonlinear regression models, it is therefore important to have practically useful and easy to interpret methodology that is robust to the variance structure. Furthermore, given the number of chemicals that are investigated in the qHTS assay, outliers and influential observations are not uncommon. In this article, we describe preliminary test estimation (PTE)-based methodology that is robust to the variance structure as well as any potential outliers and influential observations. Performance of the proposed methodology is evaluated in terms of false discovery rate (FDR) and power using a simulation study mimicking a real qHTS data. Of the two methods currently in use, our simulations studies suggest that one is extremely conservative with very small power in comparison to the proposed PTE-based method whereas the other method is very liberal. In contrast, the proposed PTE-based methodology achieves a better control of FDR while maintaining good power. The proposed methodology is illustrated using a dataset obtained from the National Toxicology Program (NTP). Additional information, simulation results, data, and computer code are available online as supplementary materials.
引用
收藏
页码:150 / U73
页数:22
相关论文
共 50 条
  • [41] Computational Methods for Analysis of High-Throughput Screening Data
    Balakin, Konstantin V.
    Savchuk, Nikolay P.
    [J]. CURRENT COMPUTER-AIDED DRUG DESIGN, 2006, 2 (01) : 1 - 19
  • [42] Statistical practice in high-throughput screening data analysis
    Malo, N
    Hanley, JA
    Cerquozzi, S
    Pelletier, J
    Nadon, R
    [J]. NATURE BIOTECHNOLOGY, 2006, 24 (02) : 167 - 175
  • [43] HTS-IA: High Throughput Screening Information Architecture for Genomics
    Omta, Wienand A.
    Egan, David A.
    Klumperman, Judith
    Spruit, Marco R.
    Brinkkemper, Sjaak
    [J]. INTERNATIONAL JOURNAL OF HEALTHCARE INFORMATION SYSTEMS AND INFORMATICS, 2013, 8 (04) : 17 - 31
  • [44] Robust and High-Throughput Cholesterol Efflux Assay
    Dixit, Mallikarjun N.
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2014, 34
  • [45] Artificial intelligence-directed iterative clustering for lead discovery in high throughput screening (HTS) data.
    Elling, JW
    Hruska, SI
    Henne, R
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 215 : U512 - U512
  • [46] A high-throughput screening (HTS) immunochemical method for the analysis of stanozolol metabolites in cattle urine samples
    Salvador, J. -Pablo
    Sanchez-Baeza, Francisco
    Marco, M. -Pilar
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (02): : 243 - 252
  • [47] A robust bacterial assay for high-throughput screening of human 4-hydroxyphenylpyruvate dioxygenase inhibitors
    Jessie Neuckermans
    Alan Mertens
    Dinja De Win
    Ulrich Schwaneberg
    Joery De Kock
    [J]. Scientific Reports, 9
  • [48] A robust bacterial assay for high-throughput screening of human 4-hydroxyphenylpyruvate dioxygenase inhibitors
    Neuckermans, Jessie
    Mertens, Alan
    De Win, Dinja
    Schwaneberg, Ulrich
    De Kock, Joery
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [49] High-throughput screening assay for helicase enzymes
    Sivaraja, M
    Giordano, H
    Peterson, MG
    [J]. ANALYTICAL BIOCHEMISTRY, 1998, 265 (01) : 22 - 27
  • [50] Adaptation of aequorin functional assay to high throughput screening
    Le Poul, E
    Hisada, S
    Mizuguchi, Y
    Dupriez, VJ
    Burgeon, E
    Detheux, M
    [J]. JOURNAL OF BIOMOLECULAR SCREENING, 2002, 7 (01) : 57 - 65