Robust Analysis of High Throughput Screening (HTS) Assay Data

被引:13
|
作者
Lim, Changwon [1 ]
Sen, Pranab K. [2 ,3 ]
Peddada, Shyamal D. [4 ]
机构
[1] Loyola Univ, Dept Math & Stat, Chicago, IL 60660 USA
[2] Univ N Carolina, Dept Stat & Operat Res, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Biostat, Chapel Hill, NC 27599 USA
[4] NIEHS, NIH, Res Triangle Pk, NC 27709 USA
关键词
Dose-response study; False discovery rate (FDR); Heteroscedasticity; Hill model; M-estimation procedure; Nonlinear regression model; Power; Toxicology; FALSE DISCOVERY RATE;
D O I
10.1080/00401706.2012.749166
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Quantitative high throughput screening (qHTS) assays use cells or tissues to screen thousands of compounds in a short period of time. Data generated from qHTS assays are then evaluated using nonlinear regression models, such as the Hill model, and decisions regarding toxicity are made using the estimates of the parameters of the model. For any given compound, the variability in the observed response may either be constant across dose groups (homoscedasticity) or vary with dose (heteroscedasticity). Since thousands of compounds are simultaneously evaluated in a qHTS assay, it is not practically feasible for an investigator to perform residual analysis to determine the variance structure before performing statistical inferences on each compound. Since it is well known that the variance structure plays an important role in the analysis of linear and nonlinear regression models, it is therefore important to have practically useful and easy to interpret methodology that is robust to the variance structure. Furthermore, given the number of chemicals that are investigated in the qHTS assay, outliers and influential observations are not uncommon. In this article, we describe preliminary test estimation (PTE)-based methodology that is robust to the variance structure as well as any potential outliers and influential observations. Performance of the proposed methodology is evaluated in terms of false discovery rate (FDR) and power using a simulation study mimicking a real qHTS data. Of the two methods currently in use, our simulations studies suggest that one is extremely conservative with very small power in comparison to the proposed PTE-based method whereas the other method is very liberal. In contrast, the proposed PTE-based methodology achieves a better control of FDR while maintaining good power. The proposed methodology is illustrated using a dataset obtained from the National Toxicology Program (NTP). Additional information, simulation results, data, and computer code are available online as supplementary materials.
引用
收藏
页码:150 / U73
页数:22
相关论文
共 50 条
  • [1] HTS and assay miniaturization - Ultra-high-throughput screening comes of age
    Liszewski, K
    [J]. GENETIC ENGINEERING NEWS, 1998, 18 (20): : 9 - +
  • [2] A high throughput screening (HTS) assay for HCVNS3 ATPase activity
    Bedard, J
    Gervais, C
    Brunette, S
    Rando, RF
    [J]. HEPATOLOGY, 2000, 32 (04) : 383A - 383A
  • [3] Robust biofilm assay for quantification and high throughput screening applications
    Rajamani, Sathish
    Sandy, Reuel
    Kota, Krishna
    Lundh, Linnea
    Gomba, Glenn
    Recabo, Katlin
    Duplantier, Allen
    Panchal, Rekha G.
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2019, 159 : 179 - 185
  • [5] A NOVEL 3-DIMENSIONAL MIGRATION ASSAY FOR HIGH-THROUGHPUT SCREENING (HTS)
    Pflueger, M.
    Pretsch, A.
    Eger, A.
    Hundsberger, H.
    Schuett, W.
    Wiesner, C.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 440 - 440
  • [6] Practical Outcomes of Applying Ensemble Machine Learning Classifiers to High-Throughput Screening (HTS) Data Analysis and Screening
    Simmons, Kirk
    Kinney, John
    Owens, Aaron
    Kleier, Daniel A.
    Bloch, Karen
    Argentar, Dave
    Walsh, Alicia
    Vaidyanathan, Ganesh
    [J]. JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2008, 48 (11) : 2196 - 2206
  • [7] HTS-corrector: software for the statistical analysis and correction of experimental high-throughput screening data
    Makarenkov, Vladimir
    Kevorkov, Dmytro
    Zentilli, Pablo
    Gagarin, Andrei
    Malo, Nathalie
    Nadon, Robert
    [J]. BIOINFORMATICS, 2006, 22 (11) : 1408 - 1409
  • [8] Development of an electronic microtiterplate for high throughput screening (HTS)
    Spiller, E
    Frömmichen, T
    Zimmermann, A
    Sippel, AE
    Urban, GA
    [J]. PROCEEDINGS OF THE IEEE SENSORS 2003, VOLS 1 AND 2, 2003, : 1041 - 1044
  • [9] Virtual high throughput screening (v-HTS)
    Chrétien, JR
    Pintore, M
    Ros, F
    [J]. ACTUALITE CHIMIQUE, 2000, (09): : 60 - 63
  • [10] Developing a Robust and High Throughput Assay for Screening Innate Immune Training Molecules
    Forbes, Greta E.
    James, Heera
    Henderson, Mark
    John, Sinu P.
    Fraser, Iain D. C.
    [J]. JOURNAL OF IMMUNOLOGY, 2023, 210 (01):