Evaluation of a HbA1c point-of-care analyzer

被引:7
|
作者
Menendez-Valladares, Paloma [1 ]
Fernandez-Riejos, Patricia [1 ]
Sanchez-Mora, Catalina [1 ]
Perez-Perez, Antonio [1 ]
Sanchez-Margalet, Victor [1 ]
Gonzalez-Rodriguez, Concepcion [1 ]
机构
[1] Virgen Macarena Univ Hosp, Dept Clin Biochem, Seville 41009, Spain
关键词
POCT; HbA1c; Diabetes; Evaluation; GLYCATED HEMOGLOBIN; INSTRUMENTS; CAPILLARY; HBA(1C);
D O I
10.1016/j.clinbiochem.2015.03.016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: A better glycemic monitoring of diabetic patients and avoiding complications of poorly controlled diabetes could be possible with point-of-care testing technology (POCT) for HbA1c determination. B-Analyst (R) was studied to check whether it complied with the quality requirements for this purpose. Design and methods: We evaluated the B-Analyst (R) (Menarini Diagnostics), which is based in the principle of latex agglutination immunoturbidimetry, to assess the validity of the technique of HbA1c. We carried out the method comparison with the HA-8180 (R) (Menarini Diagnostics) as a reference method [High Performance Liquid Chromatography (HPLC)]. We assessed the analytical quality of the B-Analyst (R) studying the accuracy: inter-assay variability and intra-assay study. Furthermore, possible interferences by hemoglobinopathies were studied. Results: Regression analysis of the data for the method comparison between HA-8180 (R) and B-Analyst (R) showed a slope of 1.0085 and an intercept of 0.1208. The Pearson's correlation coefficient was 0.9958 (p < 0.0001). Bias study showed a mean difference from B-Analyst (R) with respect to HA-8180 (R) of 0.1872 with a 95% confidence interval. The standard error of the estimate (S-yx) was 0.2091. The concordance correlation coefficient to assess accuracy was 0.9922 (0.9891-0.9945). The CV for the inter-assay study was 1.4%. For the intra-assay study we analyzed 3 samples with different HbA1c % whose CV were 1.03% [4.7% HbA1c (28 mmol/mol)], 0.46% [6.4% HbA1c (46 mmol/mol)] and 0.78% [8.1% HbA1c (65 mmol/mol)]. Conclusion: The B-Analyst (R) evaluated not only showed good correlation with HA-8180 (R), but also it presented a great accuracy both in the inter-assay and in the intra-assay studies. The 8-Analyst (R) complies with quality specifications required for monitoring of diabetic patients. (C) 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:686 / 689
页数:4
相关论文
共 50 条
  • [31] Validation and effect on diabetes control of glycated haemoglobin (HbA1c) point-of-care testing
    Pillay, S.
    Aldous, C. M.
    Singh, D.
    Pillay, D.
    SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2019, 109 (02): : 112 - 115
  • [32] Precision of the Afinion HbA1c Dx Point-of-Care Test in CLIA Waived Settings
    Clendenin, Marta
    Kupfer, Kenneth
    Green, Christopher L.
    Fortner, Kyle S.
    Bailey, Timothy S.
    Brick, Stephen
    Smiley, Sarah I.
    Strauss, Guy S.
    Thorsell, Ashley A.
    Ahmed, Naseer
    DIABETES, 2022, 71
  • [33] HbA(1c) point-of-care testing
    Solnica, Bogdan
    CLINICAL DIABETOLOGY, 2012, 1 (01): : 38 - 42
  • [34] Point-of-care testing of HbA1C is traceable to IFCC reference method by external calibration
    Zhou, Rui
    Tong, Qing
    Zuo, Chang
    Song, Zhi-Xin
    Ma, Huai-An
    Yue, Yu-Hong
    Zhang, Rui
    Wang, Qing-Tao
    CLINICA CHIMICA ACTA, 2014, 433 : 249 - 253
  • [35] Point-of-care testing of HbA1c, renal function and lipids in remote or disadvantaged regions
    Handrinos, Lena
    Januszewski, Andrzej S.
    Trimble, Elisabeth
    Donelan, Neil
    Williams, Paul
    Jenkins, Alicia J.
    INTERNAL MEDICINE JOURNAL, 2020, 50 (12) : 1567 - 1571
  • [36] Comparison between a new point-of-care HbA1c test and a routine laboratory method
    Relker, L.
    Luppa, P. B.
    CLINICA CHIMICA ACTA, 2024, 558
  • [37] HbA1c-testing: Evaluation of two point-of-care analysers
    Dubach, Irina L.
    Christ, Emanuel R.
    Diem, Peter
    PRIMARY CARE DIABETES, 2019, 13 (06) : 583 - 587
  • [38] Point-of-care testing for glycated haemoglobin (HbA1c) in the Young Persons Diabetes Clinic
    Masters, J.
    Birdsall, E. B.
    Parr, J.
    Hikmat, M.
    Oyibo, S. O.
    DIABETIC MEDICINE, 2018, 35 : 188 - 188
  • [39] Comparison of a point-of-care analyser for the determination of HbA1c against a laboratory based analyser
    Jones, D. A.
    Dunseath, G. J.
    Churm, R.
    Luzio, S. D.
    DIABETIC MEDICINE, 2016, 33 : 66 - 67
  • [40] Evaluation of the analyzer Glycomat 3000 (Biocode Hycel) for HbA1c
    Motte, Laetitia
    Guillard, Emmanuelle
    Jaisson, Stephane
    Leroy, Nathalie
    Gillery, Philippe
    ANNALES DE BIOLOGIE CLINIQUE, 2011, 69 (03) : 311 - 318