A new integrated method for X-ray image correction in radiogram

被引:0
|
作者
Li, YL [1 ]
Liu, GZ [1 ]
Pan, DH [1 ]
机构
[1] Xian Jiaotong Univ, Xian 710049, Peoples R China
来源
关键词
radiogram; multi-resolution analysis (MRA); scatter; wavelet;
D O I
10.1117/12.452834
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In industrial Radiogram, scatter noise, uneven distribution of X-ray and other noises directly affect image quality. Among them scatter noise is the major part. Many researchers have employed various methods to make model to get accurate estimation of scatter distribution. But these methods and models are difficult to perform well in other different situations. In this paper we propose a method integrated physical and mathematical processing to solve this problem perfectly. Based on the analysis of the scatter distribution in X-ray image and the contribution of the low frequency noise to image deterioration, in this paper a new integrated method is used to correct these effects as follows, First using the optical theory we deduce the expression of scatter distribution, which is proved to be subject to Gaussian distribution. The expression provides a theoretic basis for removing the scatter with physical method, by which we get remarkable quality-improved Xray images. Then multi-resolution analysis is employed to decompose the images acquired on the above theoretic basis, and it makes the processing of different frequency components of the X-ray images become easy. In our experiment, the results are satisfied. The method not only avoids making different models under different experiment conditions universally, but also provides a promising way for real-time X-ray image correction and detection.
引用
收藏
页码:116 / 123
页数:8
相关论文
共 50 条
  • [31] A new x-ray spectroscopic method.
    Seemann, FH
    PHYSIKALISCHE ZEITSCHRIFT, 1919, 20 : 55 - 58
  • [32] A new method of x-ray holographic tomography
    Xie, HL
    Chen, JW
    Gao, HY
    Lu, PX
    Xu, ZZ
    CHINESE PHYSICS LETTERS, 2002, 19 (08) : 1100 - 1102
  • [33] A NEW METHOD OF DETERMINING X-RAY INTENSITIES
    BAENZIGER, NC
    JOURNAL OF CHEMICAL PHYSICS, 1948, 16 (12): : 1175 - 1176
  • [34] A new reconstruction method for X-ray holograms
    Gao, HY
    Chen, JW
    Xie, HL
    Xiong, SS
    Li, RX
    Xu, ZZ
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 3711 - 3714
  • [35] Improving image quality of synchrotron CT by scattered X-ray correction
    Baba, Rika
    Yoneyama, Akio
    Hyodo, Kazuyuki
    Takeda, Tohoru
    Takahashi, Mariko
    Nakano, Haruhisa
    Maki, Koutaro
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [36] A new method for the x-ray treatment of leucaemia
    Dale, T
    ACTA RADIOLOGICA, 1931, 12 : 263 - 286
  • [37] Myocardial perfusion image with attenuation correction by X-ray in detection of CAD
    Yao, Z
    Zhu, M
    Qu, W
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S483 - S483
  • [38] Beam hardening fitting correction method for X-ray TICT
    Department of Phy. and Electr., Hunan University of Arts and Science, Changde 415000, China
    不详
    不详
    不详
    Guangdian Gongcheng, 2006, 11 (137-141):
  • [39] ASPECTS FOR APPLICATION OF A NEW CORRECTION PROGRAM FOR X-RAY SPECTROMETRY
    PLESCH, R
    SIEMENS ZEITSCHRIFT, 1977, 51 (10): : 841 - 844
  • [40] A new method for determining the sensitivity of X-ray imaging observations and the X-ray number counts
    Georgakakis, A.
    Nandra, K.
    Laird, E. S.
    Aird, J.
    Trichas, M.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2008, 388 (03) : 1205 - 1213