A new integrated method for X-ray image correction in radiogram

被引:0
|
作者
Li, YL [1 ]
Liu, GZ [1 ]
Pan, DH [1 ]
机构
[1] Xian Jiaotong Univ, Xian 710049, Peoples R China
来源
关键词
radiogram; multi-resolution analysis (MRA); scatter; wavelet;
D O I
10.1117/12.452834
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In industrial Radiogram, scatter noise, uneven distribution of X-ray and other noises directly affect image quality. Among them scatter noise is the major part. Many researchers have employed various methods to make model to get accurate estimation of scatter distribution. But these methods and models are difficult to perform well in other different situations. In this paper we propose a method integrated physical and mathematical processing to solve this problem perfectly. Based on the analysis of the scatter distribution in X-ray image and the contribution of the low frequency noise to image deterioration, in this paper a new integrated method is used to correct these effects as follows, First using the optical theory we deduce the expression of scatter distribution, which is proved to be subject to Gaussian distribution. The expression provides a theoretic basis for removing the scatter with physical method, by which we get remarkable quality-improved Xray images. Then multi-resolution analysis is employed to decompose the images acquired on the above theoretic basis, and it makes the processing of different frequency components of the X-ray images become easy. In our experiment, the results are satisfied. The method not only avoids making different models under different experiment conditions universally, but also provides a promising way for real-time X-ray image correction and detection.
引用
收藏
页码:116 / 123
页数:8
相关论文
共 50 条
  • [1] Novel method for correction of x-ray fluoroscopic image
    Zhang, W. Q.
    Dai, K. R.
    Wang, C. T.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6340 - 6343
  • [2] The new method of matrix correction calculation at X-ray analysis
    2012, Federal Informational-Analytical Center of the Defense Industry
  • [3] An efficient image distortion correction method for an X-ray digital tomosynthesis system
    Kim, JY
    PATTERN RECOGNITION AND MACHINE INTELLIGENCE, PROCEEDINGS, 2005, 3776 : 428 - 433
  • [4] Evaluation of image placement correction method for EB X-ray mask writing
    Watanabe, T
    Ohki, S
    Uchiyama, S
    MICROELECTRONIC ENGINEERING, 2001, 57-8 : 417 - 423
  • [5] IMAGE CORRECTION IN A CODED MASK X-RAY TELESCOPE
    WILLMORE, AP
    BERTRAM, D
    WATT, MP
    SKINNER, GK
    PONMAN, TJ
    CHURCH, MJ
    HERRING, JRH
    EYLES, CJ
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1992, 258 (03) : 621 - 628
  • [6] A new interpolation free method for X-ray CT image reconstruction
    Mitra, A
    Banerjee, S
    17TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2004, : 54 - 59
  • [7] Spatial Resolution Enhancement of Neutron Radiogram by Cooperating with X-ray Radiography
    Hasemi, H.
    Kamiyana, T.
    Sato, H.
    Kino, K.
    Nakajima, K.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [8] X-ray image method of chemical analysis
    Hamos, LV
    AMERICAN MINERALOGIST, 1938, 23 (04) : 215 - 226
  • [9] A NEW CHARGE-CORRECTION METHOD IN X-RAY PHOTOELECTRON-SPECTROSCOPY
    KOHIKI, S
    OHMURA, T
    KUSAO, K
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1983, 28 (04) : 229 - 237
  • [10] New simple method of X-ray beam hardening correction for CT reconstruction
    Fang, Zheng
    Sun, Xiaomin
    Luo, Qingming
    Guangxue Xuebao/Acta Optica Sinica, 2007, 27 (02): : 302 - 306