THE FUTURE SPACEBORNE HYPERSPECTRAL IMAGER ENMAP: ITS IN-FLIGHT RADIOMETRIC AND GEOMETRIC CALIBRATION CONCEPT

被引:0
|
作者
Schneider, M. [1 ]
Mueller, R. [1 ]
Krawzcyk, H. [2 ]
Bachmann, M. [1 ]
Storch, T. [1 ]
Mogulsky, V. [3 ]
Hofer, S. [3 ]
机构
[1] Deutsch Zentrum Luft & Raumfahrt DLR, Oberpfaffenhofen, Germany
[2] Deutsch Zentrum Luft & Raumfahrt DLR, D-12489 Berlin, Germany
[3] Kayser Threde GmbH, D-81379 Munich, Germany
来源
关键词
Geometric Calibration; Radiometric Calibration; Hyper spectral; Satellite;
D O I
暂无
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
The German Aerospace Center DLR - namely the Earth Observation Center EOC and the German Space Operations Center GSOC - is responsible for the establishment of the ground segment of the future German hyperspectral satellite mission EnMAP (Environmental Mapping and Analysis Program). The Earth Observation Center has long lasting experiences with air- and spaceborne acquisition, processing, and analysis of hyperspectral image data. In the first part of this paper, an overview of the radiometric in-flight calibration concept including dark value measurements, deep space measurements, internal lamps measurements and sun measurements is presented. Complemented by pre-launch calibration and characterization these analyses will deliver a detailed and quantitative assessment of possible changes of spectral and radiometric characteristics of the hyperspectral instrument, e.g. due to degradation of single elements. A geometric accuracy of 100 m, which will be improved to 30 m with respect to a used reference image, if it exists, will be achieved by ground processing. Therfore, and for the required co-registration accuracy between SWIR and VNIR channels, additional to the radiometric calibration, also a geometric calibration is necessary. In the second part of this paper, the concept of the geometric calibration is presented in detail. The geometric processing of EnMAP scenes will be based on laboratory calibration results. During repeated passes over selected calibration areas images will be acquired. The update of geometric camera model parameters will be done by an adjustment using ground control points, which will be extracted by automatic image matching. In the adjustment, the improvements of the attitude angles (boresight angles), the improvements of the interior orientation (view vector) and the improvements of the position data are estimated. In this paper, the improvement of the boresight angles is presented in detail as an example. The other values and combinations follow the same rules. The geometric calibration will mainly be executed during the commissioning phase, later in the mission it is only executed if required, i.e. if the geometric accuracy of the produced images is close to or exceeds the requirements of 100 m or 30 m respectively, whereas the radiometric calibration will be executed periodically during the mission with a higher frequency during commissioning phase.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [31] EO-1 advanced land imager in-flight calibration
    Mendenhall, JA
    Lencioni, DE
    Hearn, DR
    Parker, AC
    EARTH OBSERVING SYSTEMS III, 1998, 3439 : 416 - 422
  • [32] SCIAMACHY Level 1 data:: calibration concept and in-flight calibration
    Lichtenberg, G.
    Kleipool, Q.
    Krijger, J. M.
    van Soest, G.
    van Hees, R.
    Tilstra, L. G.
    Acarreta, J. R.
    Aben, I.
    Ahlers, B.
    Bovensmann, H.
    Chance, K.
    Gloudemans, A. M. S.
    Hoogeveen, R. W. M.
    Jongma, R. T. N.
    Noel, S.
    Piters, A.
    Schrijver, H.
    Schrijvers, C.
    Sioris, C. E.
    Skupin, J.
    Slijkhuis, S.
    Stammes, P.
    Wuttke, M.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2006, 6 : 5347 - 5367
  • [33] IN-FLIGHT GEOMETRIC CALIBRATION OF THE LUNAR RECONNAISSANCE ORBITER CAMERA
    Speyerer, E. J.
    Wagner, R. V.
    Robinson, M. S.
    Humm, D. C.
    Becker, K.
    Anderson, J.
    Thomas, P.
    XXII ISPRS CONGRESS, TECHNICAL COMMISSION IV, 2012, 39-B4 : 511 - 516
  • [34] On the problem of in-flight geometric calibration using unknown landmarks
    Tkachenko, A.I.
    Journal of Automation and Information Sciences, 2014, 46 (01) : 42 - 52
  • [35] EnMAP Hyperspectral Imager:: an advanced optical payload for future applications in Earth observation programs
    Hofer, S.
    Kaufmann, H. J.
    Stuffler, T.
    Penne, B.
    Schreier, G.
    Mueller, A.
    Eckardt, A.
    Bach, H.
    Benz, U. C.
    Haydn, R.
    REMOTE SENSING FOR ENVIRONMENTAL MONITORING, GIS APPLICATIONS AND GEOLOGY VI, 2006, 6366
  • [36] Derivation of the final OSIRIS-REx OVIRS in-flight radiometric calibration
    Simon, Amy A.
    Reuter, Dennis C.
    Lauretta, Dante S.
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2021, 7 (02)
  • [37] In-flight radiometric and spatial calibration of EO-1 optical sensors
    Biggar, SF
    Thome, KJ
    Holmes, JM
    Kuester, MA
    Schowengerdt, RA
    IGARSS 2001: SCANNING THE PRESENT AND RESOLVING THE FUTURE, VOLS 1-7, PROCEEDINGS, 2001, : 305 - 307
  • [38] In-flight radiometric calibration of HYDICE using a reflectance-based approach
    Thome, KJ
    GustafsonBold, CL
    Slater, PN
    Farrand, WH
    HYPERSPECTRAL REMOTE SENSING AND APPLICATIONS, 1996, 2821 : 311 - 319
  • [39] The in-flight monitoring and validation of the SOHOCDS Normal Incidence Spectrometer radiometric calibration
    Lang, J.
    Brooks, D. H.
    Lanzafame, A. C.
    Martin, R.
    Pike, C. D.
    Thompson, W. T.
    ASTRONOMY & ASTROPHYSICS, 2007, 463 (01) : 339 - 351
  • [40] Uncertainty analysis of in-flight spectral calibration for hyperspectral imaging spectrometers
    Zhao, Huijie
    Geng, Ruonan
    Jia, Guorui
    Wang, Daming
    IMAGE AND SIGNAL PROCESSING FOR REMOTE SENSING XXIII, 2017, 10427